Key parameters
Fits liquid wet/dry point-level detection where a vibrating-fork switch is specified — electronics cassette options for direct load, PNP/PLC, relay DPCO, or NAMUR — with mid-range media to +180 °C or high-temperature options to +260 °C and SIL 2 (SIL 3 capable) listing.
Key advantages
- Vibrating-fork liquid switch — Wet/dry point level without a continuous level transmitter.
- Cassette outputs — Direct load, PNP/PLC, relay DPCO, or NAMUR electronics options.
- +180 °C / +260 °C — Mid-range to +180 °C; high-temperature options to +260 °C.
- SIL 2 (SIL 3 capable) — IEC 61508 listing with Ex/IS/XP options by code.
- Heartbeat LED + mag test — Local status/diagnostics and magnetic test point.
Typical applications
- High/low liquid level switching in tanks and pipes.
- Overfill and dry-run protection where a fork switch is preferred to floats.
- SIL-rated liquid point-level trips with cassette-matched outputs.
Selection guide
- Function — Vibrating-fork point level switch for liquids (wet/dry detection).
- Output — Direct load (2-wire AC/DC); PNP/PLC 3-wire; Relay DPCO; NAMUR (electronics cassette options).
- Supply — Direct load 20–264 Vac / 20–60 Vdc; PNP 20–60 Vdc; Relay 20–264 Vac / 20–60 Vdc; NAMUR 8 V (per PDS).
- Process connection — Threaded, flanged, and hygienic options per 00813-0100-4130 ordering table.
- Wetted materials — 316/316L stainless steel fork; polished options for hygienic service.
- Media temperature — Mid-range −40 to +180 °C; high-temperature −70 to +260 °C.
- Process pressure — Up to ~1450 psig class (derated with temperature; see OEM pressure/temperature charts).
- Approvals — SIL 2 certified to IEC 61508 (SIL 3 capable), Ex/IS/XP options by order code.
Common mistakes
- Ordering mid-range electronics when process temperature needs the +260 °C high-temperature option.
- Leaving output cassette blank — direct load vs PNP vs relay vs NAMUR changes wiring and supply.
- Assuming continuous level measurement — 2130 is a point-level switch.
- Claiming SIL/Ex coverage without the matching order codes on the quote.
- Ignoring density / turbulence — use switching delay and OEM application notes for splash/aeration.
When to RFQ / what to tell us
- Media, density, temperature, pressure, and wet/dry switching duty.
- Process connection (thread/flange/hygienic) and fork material/polish need.
- Electronics cassette (direct load / PNP / relay / NAMUR) and required SIL/Ex marks.
- Quantity, ship-to country.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 38791 |
| Brand | Rosemount |
| Model | 2130 |
| Product type | level_switch |
| Measuring range | Vibrating-fork point level switch for liquids (wet/dry detection) |
| Accuracy | Switching based on fork natural-frequency change; adjustable switching delay for turbulence/splash |
| Output signal | Direct load (2-wire AC/DC); PNP/PLC 3-wire; Relay DPCO; NAMUR (electronics cassette options) |
| Supply voltage | Direct load 20–264 Vac / 20–60 Vdc; PNP 20–60 Vdc; Relay 20–264 Vac / 20–60 Vdc; NAMUR 8 V (per PDS) |
| Process connection | Threaded, flanged, and hygienic options per 00813-0100-4130 ordering table |
| Wetted materials | 316/316L stainless steel fork; polished options for hygienic service |
| Housing material | Aluminum / SST housings per electronics and hazardous-area codes |
| IP rating | Per housing/electronics selection in PDS 00813-0100-4130 |
| Media temperature | Mid-range −40 to +180 °C (−40 to +356 °F); high-temperature −70 to +260 °C (−94 to +500 °F) |
| Ambient temperature | Per electronics cassette tables in PDS |
| Process pressure | Up to ~1450 psig class (derated with temperature; see PDS pressure/temperature charts) |
| Min density | Liquid density detection via vibronic principle (see PDS application notes) |
| Communication | Local heartbeat LED status/diagnostics; magnetic test point |
| Display | Heartbeat LED on electronics cassette |
| Approvals | SIL 2 certified to IEC 61508 (SIL 3 capable), Ex/IS/XP options, CE |
| Notes | Specs from Emerson Rosemount PDS 00813-0100-4130 Rev EI (Sep 2024) + product page. |
Documents
FAQ
Q: Which output cassette? A: Direct load 2-wire AC/DC; PNP/PLC 3-wire; Relay DPCO; or NAMUR — each has its own supply window per PDS.
Q: Media temperature classes? A: Mid-range −40 to +180 °C; high-temperature −70 to +260 °C — lock class on the RFQ.
Q: What should I send for a quote? A: Cassette, connection, T/P, Ex/SIL, quantity. Compatible with systems using Rosemount 2130 — we do not claim authorized-dealer status.
Links
| Parameter | Value |
|---|---|
| Measuring range | Vibrating-fork point level switch for liquids (wet/dry detection) |
| Accuracy | Switching based on fork natural-frequency change; adjustable switching delay for turbulence/splash |
| Output | Direct load (2-wire AC/DC); PNP/PLC 3-wire; Relay DPCO; NAMUR (electronics cassette options) |
| Supply | Direct load 20–264 Vac / 20–60 Vdc; PNP 20–60 Vdc; Relay 20–264 Vac / 20–60 Vdc; NAMUR 8 V (per PDS) |
| Process connection | Threaded, flanged, and hygienic options per 00813-0100-4130 ordering table |
| Wetted parts | 316/316L stainless steel fork; polished options for hygienic service |
| Housing | Aluminum / SST housings per electronics and hazardous-area codes |
| Protection | Per housing/electronics selection in PDS 00813-0100-4130 |
| Media temperature | Mid-range −40 to +180 °C (−40 to +356 °F); high-temperature −70 to +260 °C (−94 to +500 °F) |
| Ambient temperature | Per electronics cassette tables in PDS |
| Display | Heartbeat LED on electronics cassette |
| Communication | Local heartbeat LED status/diagnostics; magnetic test point |
| Approvals | SIL 2 certified to IEC 61508 (SIL 3 capable); Ex/IS/XP options; CE |
| Notes | Specs from Emerson Rosemount PDS 00813-0100-4130 Rev EI (Sep 2024) + product page. |
| Process Pressure | Up to ~1450 psig class (derated with temperature; see PDS pressure/temperature charts) |
| Min Density | Liquid density detection via vibronic principle (see PDS application notes) |