Key parameters

Measuring range
Point level (vibronic); density >0.7 g/cm³ (optional >0.5 g/cm³)
Accuracy
Switch point ~13 mm from tip (vertical from above, water); switching delay standard 0.5 s / 1 s
Output
3-wire DC-PNP (to 200 mA) or 2-wire AC/DC load switch (to 250 mA); MAX/MIN modes; IO-Link option
Supply
DC-PNP 10–30 V DC; AC/DC 20–253 V AC/DC
Process connection
Threaded compact process connections (see TI01147 order codes)
Wetted parts
316L stainless steel sensor; surface roughness 3.2 µm
Download datasheet PDF

Fits compact liquid point level where you need an Endress+Hauser Liquiphant FTL31. Vibronic switch for liquids with density above 0.7 g/cm³ (optional >0.5), switch point about 13 mm from tip, 3-wire DC-PNP (10–30 VDC) or 2-wire AC/DC (20–253 V) outputs with IO-Link option, and threaded 316L sensor.

Key advantages

  • Principle — Vibronic point level
  • Density — >0.7 g/cm³ (optional >0.5)
  • Outputs — DC-PNP 10–30 V / AC-DC 20–253 V
  • Delay — Standard 0.5 s / 1 s
  • Wetted — 316L stainless sensor

Typical applications

  • Tank overflow / dry-run.
  • Compact point level.
  • Machine liquid detection.

Selection guide

  • DC-PNP vs AC/DC
  • Thread size
  • Density option

Common mistakes

  • Density too low.
  • Wrong supply electronics.
  • Buildup on fork.

When to RFQ / what to tell us

  1. Thread/output.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU46996
BrandEndress+Hauser
ModelLiquiphant FTL31
Product typeLevel Switch
Measuring rangePoint level (vibronic); density >0.7 g/cm³ (optional >0.5 g/cm³)
AccuracySwitch point ~13 mm from tip (vertical from above, water); switching delay standard 0.5 s / 1 s
Output signal3-wire DC-PNP (to 200 mA) or 2-wire AC/DC load switch (to 250 mA); MAX/MIN modes; IO-Link option
Supply voltageDC-PNP 10–30 V DC; AC/DC 20–253 V AC/DC
Process connectionThreaded compact process connections
Wetted materials316L stainless steel sensor; surface roughness 3.2 µm

Documents

FAQ

Q: Supply DC-PNP? A: 10–30 VDC.

Q: Density? A: >0.7 g/cm³ standard.

Q: What should I send for a quote? A: Thread/output, quantity, ship-to.

Links

ParameterValue
Measuring rangePoint level (vibronic); density >0.7 g/cm³ (optional >0.5 g/cm³)
AccuracySwitch point ~13 mm from tip (vertical from above, water); switching delay standard 0.5 s / 1 s
Output3-wire DC-PNP (to 200 mA) or 2-wire AC/DC load switch (to 250 mA); MAX/MIN modes; IO-Link option
SupplyDC-PNP 10–30 V DC; AC/DC 20–253 V AC/DC
Process connectionThreaded compact process connections (see TI01147 order codes)
Wetted parts316L stainless steel sensor; surface roughness 3.2 µm
HousingStainless steel housing (316L); M12 / valve plug / cable options
ProtectionIP65/67 (M12); IP65 (valve plug); IP66/68 (cable); IP66/68/69K (M12 metal cover)
Media temperature−40 to +150 °C (−40 to +302 °F) depending on version
Ambient temperature−40 to +70 °C (see derating)
DisplayLED status indication; external function test with test magnet
CommunicationIO-Link capability (parameter setting)
ApprovalsWHG overfill/leakage detection; CE; Not for hazardous areas (use FTL33 for hygiene / other Liquiphant for Ex)
NotesSpecs from Endress+Hauser TI01147F/00/EN/05.22-00 and product page. Compact vibronic point level switch for liquids.
Process PressureVacuum … 40 bar (−1 to +40 bar / −14.5 to 580 psi)
Min Density>0.7 g/cm³ (optional >0.5 g/cm³)