Endress+Hauser

Endress+Hauser Liquiphant FTL51B Vibronic Level Switch

SKU · 47689 · Liquiphant FTL51B · Brand: Endress+Hauser
Available
Quote on request
No online payment · add lines to RFQ BOM

E+H Liquiphant FTL51B: vibronic point level; to 6 m; FEL inserts; 316L/Alloy. RFQ.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Measuring range
Point level; sensor length up to 6 m (20 ft) depending on installation/extension ordered
Accuracy
Millimetre-class switching point (product-independent); hysteresis/switching delay per electronics
Output
Electronic inserts: 2-wire AC (FEL61); 3-wire DC PNP (FEL62); universal AC/DC relay (FEL64); DC relay (FEL64DC); PFM (FEL67); 2-wire NAMUR (FEL68); HART/PROFINET-APL variants in related TI
Supply
Depends on insert: e.g. FEL61 19–253 VAC; FEL62 PLC PNP (SELV/CLASS 2); FEL64 19–253 VAC / 19–55 VDC; FEL64DC 9–20 VDC
Process connection
Threads, flanges, hygienic (Tri-Clamp) per order
Wetted parts
316L, Alloy (sensor); process adapters per TI
Download datasheet PDF

Fits extended vibronic point level where you need an Endress+Hauser Liquiphant FTL51B. Point-level switch with sensor length up to 6 m depending on extension, millimetre-class product-independent switching, electronic inserts including 2-wire AC, 3-wire DC-PNP and universal AC/DC relay, with 316L/Alloy wetted options.

Key advantages

  • Length — Sensor up to 6 m (20 ft)
  • Principle — Vibronic point level
  • Inserts — FEL61/62/64 and variants
  • Connections — Thread / flange / hygienic
  • Wetted — 316L, Alloy options

Typical applications

  • Tank high/low level.
  • Pump dry-run protection.
  • Extended vibronic probes.

Selection guide

  • Sensor length
  • Electronic insert
  • Process connection

Common mistakes

  • Wrong insert voltage.
  • Buildup on fork.
  • Density too low.

When to RFQ / what to tell us

  1. Length/insert/connection.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU47689
BrandEndress+Hauser
ModelLiquiphant FTL51B
Product typeLevel Switch
Measuring rangePoint level; sensor length up to 6 m (20 ft) depending on installation/extension ordered
AccuracyMillimetre-class switching point (product-independent); hysteresis/switching delay per electronics
Output signalElectronic inserts: 2-wire AC (FEL61); 3-wire DC PNP (FEL62); universal AC/DC relay (FEL64); DC relay (FEL64DC); PFM (FEL67); 2-wire NAMUR (FEL68); HART/PROFINET-APL variants in related TI
Supply voltageDepends on insert: e.g. FEL61 19–253 VAC; FEL62 PLC PNP (SELV/CLASS 2); FEL64 19–253 VAC / 19–55 VDC; FEL64DC 9–20 VDC
Process connectionThreads, flanges, hygienic (Tri-Clamp) per order
Wetted materials316L, Alloy (sensor); process adapters

Documents

FAQ

Q: Max length? A: Up to 6 m.

Q: Inserts? A: FEL61/62/64 and variants.

Q: What should I send for a quote? A: Length/insert/connection, quantity, ship-to.

Links

ParameterValue
Measuring rangePoint level; sensor length up to 6 m (20 ft) depending on installation/extension ordered
AccuracyMillimetre-class switching point (product-independent); hysteresis/switching delay per electronics
OutputElectronic inserts: 2-wire AC (FEL61); 3-wire DC PNP (FEL62); universal AC/DC relay (FEL64); DC relay (FEL64DC); PFM (FEL67); 2-wire NAMUR (FEL68); HART/PROFINET-APL variants in related TI
SupplyDepends on insert: e.g. FEL61 19–253 VAC; FEL62 PLC PNP (SELV/CLASS 2); FEL64 19–253 VAC / 19–55 VDC; FEL64DC 9–20 VDC
Process connectionThreads, flanges, hygienic (Tri-Clamp) per order
Wetted parts316L, Alloy (sensor); process adapters per TI
HousingField housing with M20 / ½ NPT / M12 entries
ProtectionIP66/68 NEMA Type 4X/6P (cable entries); M12 plugged IP66/67; IP68 test 1.83 m H2O 24 h
Media temperature−50 to +150 °C (−58 to +302 °F)
Ambient temperatureAmbient range per TI environment section (electronics options to −60 °C LT)
DisplayOptional LED module VU120; Bluetooth module VU121
CommunicationBluetooth (Heartbeat/SmartBlue); optional HART / Ethernet-APL variants
ApprovalsSIL2; SIL3; ATEX; IECEx; WHG; CE
NotesSpecs from E+H TI01403F EN 07.25-00 (2025-10-13).
Process PressureVacuum…100 bar (1450 psi)
Min Density0.5 g/cm³ (0.4 g/cm³ optional); density selection switch >0.7 g/cm³ typical
ViscosityUp to 10000 mPa·s