E+H Soliphant FTM51 Level Switch
E+H Soliphant FTM51 vibronic solids level switch; fork from 10 g/l; −50…+280 °C; SIL 2. RFQ + selection help.
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Fits fine-grained or dusty bulk-solids point level where a vibronic fork is specified — extension pipe 300–4000 mm (to 6000 mm on request), standard fork from 10 g/l (short fork 50 g/l), media −50 to +280 °C, vacuum…25 bar, with SIL 2 and broad Ex marks.
Key advantages
- Vibronic solids point level — Fine-grained/dusty bulk solids; no media calibration required.
- Low density capability — Standard fork from 10 g/l; short fork 50 g/l.
- Extension 300–4000 mm — To 6000 mm on request; media −50…+280 °C; vacuum…25 bar.
- SIL 2 capable — Multiple electronic inserts (DC-PNP, AC, relay, NAMUR, PFM) and Ex marks by code.
Typical applications
- Silo and hopper high/low alarms on powders and dusty bulk solids.
- Plants specifying vibronic forks instead of paddle or capacitance solids switches.
- SIL-rated solids overfill / empty protection by matching order codes.
Selection guide
- Measuring range — Vibronic point level for fine-grained/dusty bulk solids; extension pipe 300–4000 mm (to 6000 mm on request).
- Accuracy — No media calibration required; selectable density setting and switching delay.
- Output — DC-PNP 3-wire; AC 2-wire; relay DPDT; 8/16 mA; NAMUR; PFM (electronic insert dependent).
- Supply — Per electronic insert (AC 19…253 V; DC options; NAMUR/PFM per TI01571).
- Process connection — Thread R 1½ / NPT 1¼–1½; EN/ASME/JIS flanges; Tri-Clamp hygienic.
- Wetted materials — 316L (3.2 µm / 0.8 µm); PTFE coated; ETFE coated options.
- Housing — Aluminum / stainless / polyester housing codes per TI.
- IP — Per housing selection in TI01571.
- Media temperature — −50 to +280 °C (−60 to +540 °F).
- Ambient — −50 to +70 °C (−60 to +160 °F).
- Process pressure — Vacuum … 25 bar (Vacuum … 360 psi).
- Min density — Standard fork 10 g/l; short fork 50 g/l.
- Communication — PFM / NAMUR switching to FTL325/FTL375 family switching units.
- Display — Switch status visible externally (housing-dependent).
- Approvals — SIL 2 IEC 61508, ATEX/FM/CSA/IECEx/INMETRO/NEPSI/EAC, EN 10204-3.1.
- Notes — Specs from Endress+Hauser TI01571F/00/EN/03.21 and FTM51 product page..
Common mistakes
- Using liquid vibrating-fork assumptions — FTM51 is for fine-grained/dusty bulk solids; min density 10 g/l (standard) / 50 g/l (short).
- Leaving electronic insert blank — DC-PNP / AC 2-wire / relay DPDT / 8/16 mA / NAMUR / PFM change supply and switching-unit pairing (FTL325/FTL375).
- Undersizing extension — 300–4000 mm standard; to 6000 mm on request.
- Ignoring coating options (PTFE/ETFE) when product builds up on 316L.
When to RFQ / what to tell us
- Bulk solid density/particle size, extension length, standard vs short fork, and electronic insert.
- Process connection (thread/flange/Tri-Clamp), coating, Ex/SIL, media T/P.
- Quantity, ship-to, switching-unit need (FTL325/FTL375) if PFM/NAMUR.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 47892 |
| Brand | Endress+Hauser |
| Model | Soliphant FTM51 |
| Product type | level_switch |
| Measuring range | Vibronic point level for fine-grained/dusty bulk solids; extension pipe 300–4000 mm (to 6000 mm on request) |
| Accuracy | No media calibration required; selectable density setting and switching delay |
| Output signal | DC-PNP 3-wire; AC 2-wire; relay DPDT; 8/16 mA; NAMUR; PFM (electronic insert dependent) |
| Supply voltage | Per electronic insert (AC 19…253 V; DC options; NAMUR/PFM per TI01571) |
| Process connection | Thread R 1½ / NPT 1¼–1½; EN/ASME/JIS flanges; Tri-Clamp hygienic |
| Wetted materials | 316L (3.2 µm / 0.8 µm); PTFE coated; ETFE coated options |
| Housing material | Aluminum / stainless / polyester housing codes per TI |
| IP rating | Per housing selection in TI01571 |
| Media temperature | −50 to +280 °C (−60 to +540 °F) |
| Ambient temperature | −50 to +70 °C (−60 to +160 °F) |
| Process pressure | Vacuum … 25 bar (Vacuum … 360 psi) |
| Min density | Standard fork 10 g/l; short fork 50 g/l |
| Communication | PFM / NAMUR switching to FTL325/FTL375 family switching units |
| Display | Switch status visible externally (housing-dependent) |
| Approvals | SIL 2 IEC 61508, ATEX/FM/CSA/IECEx/INMETRO/NEPSI/EAC, EN 10204-3.1 |
| Notes | Specs from Endress+Hauser TI01571F/00/EN/03.21 and FTM51 product page. |
Documents
FAQ
Q: Liquid or solids? A: Vibronic point level for fine-grained/dusty bulk solids — not a liquid fork.
Q: Min density? A: Standard fork 10 g/l; short fork 50 g/l — selectable density setting and switching delay; no media calibration required.
Q: What should I send for a quote? A: Density, length, insert, connection, Ex/SIL, quantity. Compatible with systems using E+H Soliphant FTM51 — we do not claim authorized-dealer status.
Links
| Parameter | Value |
|---|---|
| Measuring range | Vibronic point level for fine-grained/dusty bulk solids; extension pipe 300–4000 mm (to 6000 mm on request) |
| Accuracy | No media calibration required; selectable density setting and switching delay |
| Output | DC-PNP 3-wire; AC 2-wire; relay DPDT; 8/16 mA; NAMUR; PFM (electronic insert dependent) |
| Supply | Per electronic insert (AC 19…253 V; DC options; NAMUR/PFM per TI01571) |
| Process connection | Thread R 1½ / NPT 1¼–1½; EN/ASME/JIS flanges; Tri-Clamp hygienic |
| Wetted parts | 316L (3.2 µm / 0.8 µm); PTFE coated; ETFE coated options |
| Housing | Aluminum / stainless / polyester housing codes per TI |
| Protection | Per housing selection in TI01571 |
| Media temperature | −50 to +280 °C (−60 to +540 °F) |
| Ambient temperature | −50 to +70 °C (−60 to +160 °F) |
| Display | Switch status visible externally (housing-dependent) |
| Communication | PFM / NAMUR switching to FTL325/FTL375 family switching units |
| Approvals | SIL 2 IEC 61508; ATEX/FM/CSA/IECEx/INMETRO/NEPSI/EAC; EN 10204-3.1 |
| Notes | Specs from Endress+Hauser TI01571F/00/EN/03.21 and FTM51 product page. |
| Process Pressure | Vacuum … 25 bar (Vacuum … 360 psi) |
| Min Density | Standard fork 10 g/l; short fork 50 g/l |