Endress+Hauser

E+H Soliphant FTM51 Level Switch

SKU · 47892 · Soliphant FTM51 · Brand: Endress+Hauser
Available
Quote on request
No online payment · add lines to RFQ BOM

E+H Soliphant FTM51 vibronic solids level switch; fork from 10 g/l; −50…+280 °C; SIL 2. RFQ + selection help.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Measuring range
Vibronic point level for fine-grained/dusty bulk solids; extension pipe 300–4000 mm (to 6000 mm on request)
Accuracy
No media calibration required; selectable density setting and switching delay
Output
DC-PNP 3-wire; AC 2-wire; relay DPDT; 8/16 mA; NAMUR; PFM (electronic insert dependent)
Supply
Per electronic insert (AC 19…253 V; DC options; NAMUR/PFM per TI01571)
Process connection
Thread R 1½ / NPT 1¼–1½; EN/ASME/JIS flanges; Tri-Clamp hygienic
Wetted parts
316L (3.2 µm / 0.8 µm); PTFE coated; ETFE coated options
Download datasheet PDF

Fits fine-grained or dusty bulk-solids point level where a vibronic fork is specified — extension pipe 300–4000 mm (to 6000 mm on request), standard fork from 10 g/l (short fork 50 g/l), media −50 to +280 °C, vacuum…25 bar, with SIL 2 and broad Ex marks.

Key advantages

  • Vibronic solids point level — Fine-grained/dusty bulk solids; no media calibration required.
  • Low density capability — Standard fork from 10 g/l; short fork 50 g/l.
  • Extension 300–4000 mm — To 6000 mm on request; media −50…+280 °C; vacuum…25 bar.
  • SIL 2 capable — Multiple electronic inserts (DC-PNP, AC, relay, NAMUR, PFM) and Ex marks by code.

Typical applications

  • Silo and hopper high/low alarms on powders and dusty bulk solids.
  • Plants specifying vibronic forks instead of paddle or capacitance solids switches.
  • SIL-rated solids overfill / empty protection by matching order codes.

Selection guide

  • Measuring range — Vibronic point level for fine-grained/dusty bulk solids; extension pipe 300–4000 mm (to 6000 mm on request).
  • Accuracy — No media calibration required; selectable density setting and switching delay.
  • Output — DC-PNP 3-wire; AC 2-wire; relay DPDT; 8/16 mA; NAMUR; PFM (electronic insert dependent).
  • Supply — Per electronic insert (AC 19…253 V; DC options; NAMUR/PFM per TI01571).
  • Process connection — Thread R 1½ / NPT 1¼–1½; EN/ASME/JIS flanges; Tri-Clamp hygienic.
  • Wetted materials — 316L (3.2 µm / 0.8 µm); PTFE coated; ETFE coated options.
  • Housing — Aluminum / stainless / polyester housing codes per TI.
  • IP — Per housing selection in TI01571.
  • Media temperature — −50 to +280 °C (−60 to +540 °F).
  • Ambient — −50 to +70 °C (−60 to +160 °F).
  • Process pressure — Vacuum … 25 bar (Vacuum … 360 psi).
  • Min density — Standard fork 10 g/l; short fork 50 g/l.
  • Communication — PFM / NAMUR switching to FTL325/FTL375 family switching units.
  • Display — Switch status visible externally (housing-dependent).
  • Approvals — SIL 2 IEC 61508, ATEX/FM/CSA/IECEx/INMETRO/NEPSI/EAC, EN 10204-3.1.
  • Notes — Specs from Endress+Hauser TI01571F/00/EN/03.21 and FTM51 product page..

Common mistakes

  • Using liquid vibrating-fork assumptions — FTM51 is for fine-grained/dusty bulk solids; min density 10 g/l (standard) / 50 g/l (short).
  • Leaving electronic insert blank — DC-PNP / AC 2-wire / relay DPDT / 8/16 mA / NAMUR / PFM change supply and switching-unit pairing (FTL325/FTL375).
  • Undersizing extension — 300–4000 mm standard; to 6000 mm on request.
  • Ignoring coating options (PTFE/ETFE) when product builds up on 316L.

When to RFQ / what to tell us

  1. Bulk solid density/particle size, extension length, standard vs short fork, and electronic insert.
  2. Process connection (thread/flange/Tri-Clamp), coating, Ex/SIL, media T/P.
  3. Quantity, ship-to, switching-unit need (FTL325/FTL375) if PFM/NAMUR.

Request a Quote · Get selection help

Specs

SpecValue
SKU47892
BrandEndress+Hauser
ModelSoliphant FTM51
Product typelevel_switch
Measuring rangeVibronic point level for fine-grained/dusty bulk solids; extension pipe 300–4000 mm (to 6000 mm on request)
AccuracyNo media calibration required; selectable density setting and switching delay
Output signalDC-PNP 3-wire; AC 2-wire; relay DPDT; 8/16 mA; NAMUR; PFM (electronic insert dependent)
Supply voltagePer electronic insert (AC 19…253 V; DC options; NAMUR/PFM per TI01571)
Process connectionThread R 1½ / NPT 1¼–1½; EN/ASME/JIS flanges; Tri-Clamp hygienic
Wetted materials316L (3.2 µm / 0.8 µm); PTFE coated; ETFE coated options
Housing materialAluminum / stainless / polyester housing codes per TI
IP ratingPer housing selection in TI01571
Media temperature−50 to +280 °C (−60 to +540 °F)
Ambient temperature−50 to +70 °C (−60 to +160 °F)
Process pressureVacuum … 25 bar (Vacuum … 360 psi)
Min densityStandard fork 10 g/l; short fork 50 g/l
CommunicationPFM / NAMUR switching to FTL325/FTL375 family switching units
DisplaySwitch status visible externally (housing-dependent)
ApprovalsSIL 2 IEC 61508, ATEX/FM/CSA/IECEx/INMETRO/NEPSI/EAC, EN 10204-3.1
NotesSpecs from Endress+Hauser TI01571F/00/EN/03.21 and FTM51 product page.

Documents

FAQ

Q: Liquid or solids? A: Vibronic point level for fine-grained/dusty bulk solids — not a liquid fork.

Q: Min density? A: Standard fork 10 g/l; short fork 50 g/l — selectable density setting and switching delay; no media calibration required.

Q: What should I send for a quote? A: Density, length, insert, connection, Ex/SIL, quantity. Compatible with systems using E+H Soliphant FTM51 — we do not claim authorized-dealer status.

Links

ParameterValue
Measuring rangeVibronic point level for fine-grained/dusty bulk solids; extension pipe 300–4000 mm (to 6000 mm on request)
AccuracyNo media calibration required; selectable density setting and switching delay
OutputDC-PNP 3-wire; AC 2-wire; relay DPDT; 8/16 mA; NAMUR; PFM (electronic insert dependent)
SupplyPer electronic insert (AC 19…253 V; DC options; NAMUR/PFM per TI01571)
Process connectionThread R 1½ / NPT 1¼–1½; EN/ASME/JIS flanges; Tri-Clamp hygienic
Wetted parts316L (3.2 µm / 0.8 µm); PTFE coated; ETFE coated options
HousingAluminum / stainless / polyester housing codes per TI
ProtectionPer housing selection in TI01571
Media temperature−50 to +280 °C (−60 to +540 °F)
Ambient temperature−50 to +70 °C (−60 to +160 °F)
DisplaySwitch status visible externally (housing-dependent)
CommunicationPFM / NAMUR switching to FTL325/FTL375 family switching units
ApprovalsSIL 2 IEC 61508; ATEX/FM/CSA/IECEx/INMETRO/NEPSI/EAC; EN 10204-3.1
NotesSpecs from Endress+Hauser TI01571F/00/EN/03.21 and FTM51 product page.
Process PressureVacuum … 25 bar (Vacuum … 360 psi)
Min DensityStandard fork 10 g/l; short fork 50 g/l