Rosemount

Rosemount 975UR Ultraviolet Infrared Flame Detector

SKU · 43518 · 975UR Flame Detector · Brand: Rosemount
Available
Quote on request
No online payment · add lines to RFQ BOM

Rosemount 975UR: UV+IR; <20 ms; ~100°×95° FOV; 18–32 Vdc; HART/Modbus. RFQ.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Approvals
ATEX; IECEx; FM; CSA; other regional Ex approvals per PDS
Sensing
Combined ultraviolet (0.185–0.260 µm) and infrared (4.3–4.8 µm) flame detection for hydrocarbon fires
Response Time
Ultra-fast response under 20 ms for flash fires (typical selectable settings)
Detection Range
Typical gasoline/n-heptane detection on the order of ~28 m (93 ft) per PDS
Field Of View
Approximately 100° horizontal × 95° vertical (per product documentation)
Outputs
Relays, 4–20 mA, HART, RS-485 Modbus
Download datasheet PDF

Fits combined UV/IR hydrocarbon flame detection where you need a Rosemount 975UR—ultraviolet (about 0.185–0.260 µm) plus infrared (about 4.3–4.8 µm) detector with ultra-fast response under 20 ms, FOV about 100°×95°, 18–32 Vdc supply, and relays / 4–20 mA / HART / Modbus outputs.

Key advantages

  • Sensing — Combined UV + IR for hydrocarbon fires
  • Response — Under 20 ms for flash fires (typical selectable)
  • FOV — About 100° H × 95° V
  • Power — 18–32 Vdc nominal
  • Outputs — Relays, 4–20 mA, HART, RS-485 Modbus

Typical applications

  • Hydrocarbon process units.
  • Loading racks.
  • Industrial hazardous areas.

Selection guide

  • UV / IR / combined logic
  • Output set
  • Heated optics

Common mistakes

  • Wrong logic for nuisance sources.
  • Blocked FOV.
  • Supply outside 18–32 Vdc.

When to RFQ / what to tell us

  1. Logic/outputs.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU43518
BrandRosemount
Model975UR Flame Detector
Product typeFlame Detector
SensingCombined ultraviolet (0.185–0.260 µm) and infrared (4.3–4.8 µm) flame detection for hydrocarbon fires
Response timeUltra-fast response under 20 ms for flash fires (typical selectable settings)
Detection rangeTypical gasoline/n-heptane detection on the order of ~28 m (93 ft) per PDS
Field of viewApproximately 100° horizontal × 95° vertical (per product documentation)
OutputsRelays, 4–20 mA, HART, RS-485 Modbus
Power18–32 Vdc nominal supply
OpticsHeated optics to reduce condensation/icing effects
DiagnosticsBuilt-in self-test / BIT features per 975 family

Documents

FAQ

Q: Sensing bands? A: UV ~0.185–0.260 µm and IR ~4.3–4.8 µm.

Q: Power? A: 18–32 Vdc nominal.

Q: What should I send for a quote? A: Logic/outputs, quantity, ship-to.

Links

ParameterValue
ApprovalsATEX; IECEx; FM; CSA; other regional Ex approvals per PDS
SensingCombined ultraviolet (0.185–0.260 µm) and infrared (4.3–4.8 µm) flame detection for hydrocarbon fires
Response TimeUltra-fast response under 20 ms for flash fires (typical selectable settings)
Detection RangeTypical gasoline/n-heptane detection on the order of ~28 m (93 ft) per PDS
Field Of ViewApproximately 100° horizontal × 95° vertical (per product documentation)
OutputsRelays, 4–20 mA, HART, RS-485 Modbus
Power18–32 Vdc nominal supply
OpticsHeated optics to reduce condensation/icing effects
EnclosureRugged flame-detector housing for hazardous industrial areas
DiagnosticsBuilt-in self-test / BIT features per 975 family
Special FeaturesSelectable UV, IR, or combined sensing logic; part of Rosemount 975 flame detector family
Product Type Note975UR UV/IR variant; distinct from 975MR multispectrum IR (SKU 43516 in-flight)