Image unavailable
Image unavailable
ScanSense
ScanSense LS-3410-SP Shear Pin Load Cell
Quote on request
No online payment · add lines to RFQ BOM
ScanSense LS-3410-SP: shear pin; 0–5 T to 1200 T; 4–20 mA; ±0.5% lin; 12–28 V. RFQ.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Supply
12-28 VDC
Approvals
Ex ia IIC T4 Ga; Ex ia IIIC T102 C Da (ATEX/IEC)
Type
ScanSense LS-3410-SP OEM shear pin load cell / 4-20 mA transmitter
Full Scale Load
0-5 T through 1200 T (custom designs)
Linearity
+/-0.5% of full scale
Accuracy Ambient
+/-1% of full scale at ambient temperature
Fits OEM shear-pin force measurement where you need a ScanSense LS-3410-SP. Shear pin load cell with 2-wire 4–20 mA output for full-scale loads from 0–5 T through 1200 T (custom), ±0.5% FS linearity, ±1% FS ambient accuracy, 12–28 VDC supply and minimum 13 ms response.
Key advantages
- Loads — 0–5 T through 1200 T (custom)
- Output — 2-wire 4–20 mA
- Linearity — ±0.5% of full scale
- Supply — 12–28 VDC
- Response — Minimum 13 ms
Typical applications
- OEM shear-pin force.
- Structural load pins.
- Custom tonnage pins.
Selection guide
- Full-scale tonnage
- Pin dimensions
- Cable / connector
Common mistakes
- Wrong pin fit.
- Supply outside 12–28 V.
- Ignoring custom lead time.
When to RFQ / what to tell us
- Tonnage/dimensions.
- Quantity, ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 46782 |
| Brand | ScanSense |
| Model | LS-3410-SP Shear Pin Load Cell |
| Product type | Load Cell |
| Type | ScanSense LS-3410-SP OEM shear pin load cell / 4-20 mA transmitter |
| Full scale load | 0-5 T through 1200 T (custom designs) |
| Output | 4-20 mA current loop, 2-wire |
| Supply voltage | 12-28 VDC |
| Linearity | +/-0.5% of full scale |
| Accuracy ambient | +/-1% of full scale at ambient temperature |
| Response time | Minimum 13 ms |
Documents
FAQ
Q: Output? A: 2-wire 4–20 mA.
Q: Linearity? A: ±0.5% FS.
Q: What should I send for a quote? A: Tonnage/dimensions, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Supply | 12-28 VDC |
| Approvals | Ex ia IIC T4 Ga; Ex ia IIIC T102 C Da (ATEX/IEC) |
| Type | ScanSense LS-3410-SP OEM shear pin load cell / 4-20 mA transmitter |
| Full Scale Load | 0-5 T through 1200 T (custom designs) |
| Linearity | +/-0.5% of full scale |
| Accuracy Ambient | +/-1% of full scale at ambient temperature |
| Response Time | Minimum 13 ms |
| Temperature Range | -45 C to 80 C |
| Sealing | IP68; submersible on request |
| Material | Stainless steel; electronics molded/encapsulated |
| Document | ScanSense DS-0228-A OEM Shear Pin Load Cell datasheet (scansense.com) |