Image unavailable
Image unavailable
Druck
Druck DPI 800 / DPI 802 Pressure Indicator & Loop Calibrator
Quote on request
No online payment · add lines to RFQ BOM
Handheld pressure indicator/loop calibrator; 25 mbar–700 bar; IDOS. RFQ + selection help.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Type
Druck DPI 800 pressure indicator / DPI 802 pressure and loop calibrator (handheld)
Pressure Ranges
25 mbar to 700 bar (10 inH2O to 10,000 psi) including vacuum options
Configuration
Single or dual range; optional IUPM/IUPMP (IDOS) plug-and-play modules
Module Accuracy
IDOS modules to 0.05% FS all-inclusive or 0.01% precision class
Dpi802 Ma
mA measure 0 to 55.000 mA; accuracy 0.02% reading + 3 counts; 24 V loop power (35 mA max)
Dpi802 Features
Switch test; selectable 250 ohm HART loop resistor; simultaneous pressure + mA
Fits field pressure maintenance where you need a Druck DPI 800 pressure indicator or DPI 802 pressure-and-loop calibrator with IDOS modules from 25 mbar to 700 bar class.
Key advantages
- Ranges — 25 mbar to 700 bar (10 inH2O to 10,000 psi) including vacuum options
- Configuration — Single or dual range; optional IDOS plug-and-play modules
- Module accuracy — To 0.05% FS all-inclusive or 0.01% precision class
- DPI 802 loop — mA measure to 55 mA; 24 V loop power; HART 250 Ω resistor; switch test
- UI — Large backlit display; 25 pressure units; leak test; hold/max/min/avg
Typical applications
- Transmitter calibration and loop set-up.
- Pressure switch verification.
- Maintenance pressure indication with modular ranges.
Selection guide
- Model — DPI 800 indicator vs DPI 802 loop calibrator
- Ranges / modules — Fixed vs IDOS UPM
- Accuracy class — 0.05% vs 0.01% precision modules
- Loop needs — mA measure/source, HART resistor
Common mistakes
- Ordering DPI 800 when mA loop functions are required — choose DPI 802.
- Omitting IDOS module range on the RFQ.
- Expecting pneumatic pump generation without a separate pump kit.
When to RFQ / what to tell us
- DPI 800 vs 802; pressure ranges.
- IDOS modules and accuracy class; loop needs.
- Quantity and ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 18294 |
| Brand | Druck |
| Model | DPI 800 / DPI 802 Pressure Indicator and Loop Calibrator |
| Product type | Pressure / Loop Calibrator |
| Type | Druck DPI 800 pressure indicator / DPI 802 pressure and loop calibrator (handheld) |
| Pressure ranges | 25 mbar to 700 bar (10 inH2O to 10,000 psi) including vacuum options |
| Configuration | Single or dual range; optional IUPM/IUPMP (IDOS) plug-and-play modules |
| Module accuracy | IDOS modules to 0.05% FS all-inclusive or 0.01% precision class |
| DPI 802 mA | mA measure 0 to 55.000 mA; accuracy 0.02% reading + 3 counts; 24 V loop power (35 mA max) |
| DPI 802 features | Switch test; selectable 250 ohm HART loop resistor; simultaneous pressure + mA |
| Display / UI | Large backlit display; menu-driven; hold, max/min/avg, filter, alarm, tare |
| Pressure units | 25 pressure units; flow scaling; programmable leak test |
| Construction | Robust weatherproof elastomer-protected handheld for one-handed use |
Documents
FAQ
Q: DPI 800 vs DPI 802? A: DPI 800 is pressure indication; DPI 802 adds loop calibrator functions (mA, 24 V, HART resistor, switch test).
Q: What pressure span family? A: 25 mbar to 700 bar class including vacuum options.
Q: What should I send for a quote? A: Model/ranges/modules, loop needs, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Type | Druck DPI 800 pressure indicator / DPI 802 pressure and loop calibrator (handheld) |
| Pressure Ranges | 25 mbar to 700 bar (10 inH2O to 10,000 psi) including vacuum options |
| Configuration | Single or dual range; optional IUPM/IUPMP (IDOS) plug-and-play modules |
| Module Accuracy | IDOS modules to 0.05% FS all-inclusive or 0.01% precision class |
| Dpi802 Ma | mA measure 0 to 55.000 mA; accuracy 0.02% reading + 3 counts; 24 V loop power (35 mA max) |
| Dpi802 Features | Switch test; selectable 250 ohm HART loop resistor; simultaneous pressure + mA |
| Display Ui | Large backlit display; menu-driven; hold, max/min/avg, filter, alarm, tare |
| Pressure Units | 25 pressure units; flow scaling; programmable leak test |
| Construction | Robust weatherproof elastomer-protected handheld for one-handed use |
| Applications | Pressure test/maintenance, transmitter calibration, loop set-up, switch verification |
| Document | Druck DPI 800/802 Datasheet English (druck.com wp-content 2026/05) |