Key parameters

Measuring range
mA measure/source/simulate 0–20 / 4–20 mA (to 24 mA overrange); V measure 0–28 V (705/707) or mV/V source (715)
Accuracy
705: 0.02% rdg + 2 counts mA; 707: 0.015% rdg + 2 counts; 715: 0.01% + 2 counts (per Fluke loop calibrators datasheet)
Output
Source/simulate mA; 24 V loop supply while measuring; 715 also sources 0–200 mV / 0–20 V
Supply
9 V alkaline battery; 24 V internal loop supply
Process connection
Test leads / banana jacks (TL75 etc.)
Housing
Rugged handheld with holster (705/707) or 80-series DMM package (715)
Download datasheet PDF

Fits mA loop commissioning and troubleshooting where you need a handheld source/measure/simulate tool covering Fluke 705/707/715 with internal 24 V loop supply and simultaneous % of span readout.

Key advantages

  • 705 / 707 / 715 family — One SKU path covering the common Fluke mA loop handhelds.
  • 0–24 mA set — Measure/source/simulate with simultaneous % of span.
  • 24 V loop supply — Power the transmitter while measuring.
  • Model-specific accuracy — 705 0.02%; 707 0.015%; 715 0.01% (+ counts).
  • 707 HART resistor mode — 250 Ω HART resistor mode listed on 707.

Typical applications

  • Commissioning 4–20 mA transmitter loops in the field.
  • Simulating transmitters into PLC/DCS inputs during panel checkout.
  • Quick HART-device loop checks when 707’s 250 Ω mode is required.

Selection guide

  • Family — Fluke 705 / 707 / 715 per Fluke Loop Calibrators Technical Data.
  • Range — mA measure/source/simulate 0–20 / 4–20 mA (to 24 mA overrange); V measure 0–28 V (705/707); 715 also sources 0–200 mV / 0–20 V.
  • Accuracy — 705: 0.02% rdg + 2 counts mA; 707: 0.015% rdg + 2 counts; 715: 0.01% + 2 counts.
  • Output / supply — Source/simulate mA; 24 V loop supply while measuring; 9 V alkaline battery.
  • Display — Simultaneous mA and % of span; auto step/ramp; span check.
  • Communication — 707 includes 250 Ω HART resistor mode.
  • Ambient — Operating −10 to +55 °C.

Common mistakes

  • Ordering “700 Series” without naming 705 vs 707 vs 715 — accuracy, voltage source (715), and HART resistor mode (707) differ.
  • Assuming HART communication on every model — only 707 lists the 250 Ω HART resistor mode.
  • Expecting mV/V source on 705/707 — voltage source path is listed for 715.
  • Ignoring battery vs loop-powered duty — supply is 9 V alkaline with internal 24 V loop supply while measuring.

When to RFQ / what to tell us

  1. Exact model (705 / 707 / 715) and quantity.
  2. Need for HART resistor mode (707) or mV/V source (715).
  3. Ship-to, lead kit / carrying-case needs.

Request a Quote · Get selection help

Specs

SpecValue
SKU30347
BrandFluke
Model700 Series mA Loop Calibrators (705/707/715)
Product typecalibrator
Measuring rangemA measure/source/simulate 0–20 / 4–20 mA (to 24 mA overrange); V measure 0–28 V (705/707); 715 also sources 0–200 mV / 0–20 V
Accuracy705: 0.02% rdg + 2 counts mA; 707: 0.015% rdg + 2 counts; 715: 0.01% + 2 counts
Output signalSource/simulate mA; 24 V loop supply while measuring; 715 also sources 0–200 mV / 0–20 V
Supply voltage9 V alkaline battery; 24 V internal loop supply
Process connectionTest leads / banana jacks (TL75 etc.)
HousingRugged handheld with holster (705/707) or 80-series DMM package (715)
IP ratingDust/splash resistant (715 EMI tolerant package)
Ambient temperatureOperating −10 to +55 °C
Communication707 includes 250 Ω HART resistor mode
DisplaySimultaneous mA and % of span; auto step/ramp; span check
ApprovalsCSA / IEC 61010 family safety markings per model; CE EMC
NotesFamily SKU covering Fluke 705/707/715 per Fluke Loop Calibrators Technical Data PDF on media.fluke.com.

Documents

FAQ

Q: Which models does this SKU cover? A: Fluke 705, 707, and 715 per the Loop Calibrators Technical Data. Name the exact model on the RFQ — accuracy and functions differ.

Q: Does it power a 2-wire transmitter? A: Yes — internal 24 V loop supply while measuring is listed for the family.

Q: Is HART supported? A: 707 includes a 250 Ω HART resistor mode. Full HART communicator functions are not claimed for 705/715 on this page.

Q: What should I send for a quote? A: Model, quantity, HART/mV needs, accessories, ship-to. Compatible with systems using Fluke 700-series loop calibrators — we do not claim authorized-dealer status.

Links

ParameterValue
Measuring rangemA measure/source/simulate 0–20 / 4–20 mA (to 24 mA overrange); V measure 0–28 V (705/707) or mV/V source (715)
Accuracy705: 0.02% rdg + 2 counts mA; 707: 0.015% rdg + 2 counts; 715: 0.01% + 2 counts (per Fluke loop calibrators datasheet)
OutputSource/simulate mA; 24 V loop supply while measuring; 715 also sources 0–200 mV / 0–20 V
Supply9 V alkaline battery; 24 V internal loop supply
Process connectionTest leads / banana jacks (TL75 etc.)
HousingRugged handheld with holster (705/707) or 80-series DMM package (715)
ProtectionDust/splash resistant (715 EMI tolerant package)
Ambient temperatureOperating −10 to +55 °C
DisplaySimultaneous mA and % of span; auto step/ramp; span check
Communication707 includes 250 Ω HART resistor mode
ApprovalsCSA / IEC 61010 family safety markings per model; CE EMC
NotesFamily SKU covering Fluke 705/707/715 per Fluke Loop Calibrators Technical Data PDF on media.fluke.com.