Fluke 700 Series mA Loop Calibrators
Fluke 705/707/715 mA loop calibrators. Source/measure/simulate 0–24 mA, 24 V loop. RFQ + selection help.
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Fits mA loop commissioning and troubleshooting where you need a handheld source/measure/simulate tool covering Fluke 705/707/715 with internal 24 V loop supply and simultaneous % of span readout.
Key advantages
- 705 / 707 / 715 family — One SKU path covering the common Fluke mA loop handhelds.
- 0–24 mA set — Measure/source/simulate with simultaneous % of span.
- 24 V loop supply — Power the transmitter while measuring.
- Model-specific accuracy — 705 0.02%; 707 0.015%; 715 0.01% (+ counts).
- 707 HART resistor mode — 250 Ω HART resistor mode listed on 707.
Typical applications
- Commissioning 4–20 mA transmitter loops in the field.
- Simulating transmitters into PLC/DCS inputs during panel checkout.
- Quick HART-device loop checks when 707’s 250 Ω mode is required.
Selection guide
- Family — Fluke 705 / 707 / 715 per Fluke Loop Calibrators Technical Data.
- Range — mA measure/source/simulate 0–20 / 4–20 mA (to 24 mA overrange); V measure 0–28 V (705/707); 715 also sources 0–200 mV / 0–20 V.
- Accuracy — 705: 0.02% rdg + 2 counts mA; 707: 0.015% rdg + 2 counts; 715: 0.01% + 2 counts.
- Output / supply — Source/simulate mA; 24 V loop supply while measuring; 9 V alkaline battery.
- Display — Simultaneous mA and % of span; auto step/ramp; span check.
- Communication — 707 includes 250 Ω HART resistor mode.
- Ambient — Operating −10 to +55 °C.
Common mistakes
- Ordering “700 Series” without naming 705 vs 707 vs 715 — accuracy, voltage source (715), and HART resistor mode (707) differ.
- Assuming HART communication on every model — only 707 lists the 250 Ω HART resistor mode.
- Expecting mV/V source on 705/707 — voltage source path is listed for 715.
- Ignoring battery vs loop-powered duty — supply is 9 V alkaline with internal 24 V loop supply while measuring.
When to RFQ / what to tell us
- Exact model (705 / 707 / 715) and quantity.
- Need for HART resistor mode (707) or mV/V source (715).
- Ship-to, lead kit / carrying-case needs.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 30347 |
| Brand | Fluke |
| Model | 700 Series mA Loop Calibrators (705/707/715) |
| Product type | calibrator |
| Measuring range | mA measure/source/simulate 0–20 / 4–20 mA (to 24 mA overrange); V measure 0–28 V (705/707); 715 also sources 0–200 mV / 0–20 V |
| Accuracy | 705: 0.02% rdg + 2 counts mA; 707: 0.015% rdg + 2 counts; 715: 0.01% + 2 counts |
| Output signal | Source/simulate mA; 24 V loop supply while measuring; 715 also sources 0–200 mV / 0–20 V |
| Supply voltage | 9 V alkaline battery; 24 V internal loop supply |
| Process connection | Test leads / banana jacks (TL75 etc.) |
| Housing | Rugged handheld with holster (705/707) or 80-series DMM package (715) |
| IP rating | Dust/splash resistant (715 EMI tolerant package) |
| Ambient temperature | Operating −10 to +55 °C |
| Communication | 707 includes 250 Ω HART resistor mode |
| Display | Simultaneous mA and % of span; auto step/ramp; span check |
| Approvals | CSA / IEC 61010 family safety markings per model; CE EMC |
| Notes | Family SKU covering Fluke 705/707/715 per Fluke Loop Calibrators Technical Data PDF on media.fluke.com. |
Documents
- Fluke 700 Series mA Loop Calibrators (705/707/715) datasheet (PDF)
- Fluke 700 Series mA Loop Calibrators (705/707/715) datasheet (PDF)
FAQ
Q: Which models does this SKU cover? A: Fluke 705, 707, and 715 per the Loop Calibrators Technical Data. Name the exact model on the RFQ — accuracy and functions differ.
Q: Does it power a 2-wire transmitter? A: Yes — internal 24 V loop supply while measuring is listed for the family.
Q: Is HART supported? A: 707 includes a 250 Ω HART resistor mode. Full HART communicator functions are not claimed for 705/715 on this page.
Q: What should I send for a quote? A: Model, quantity, HART/mV needs, accessories, ship-to. Compatible with systems using Fluke 700-series loop calibrators — we do not claim authorized-dealer status.
Links
| Parameter | Value |
|---|---|
| Measuring range | mA measure/source/simulate 0–20 / 4–20 mA (to 24 mA overrange); V measure 0–28 V (705/707) or mV/V source (715) |
| Accuracy | 705: 0.02% rdg + 2 counts mA; 707: 0.015% rdg + 2 counts; 715: 0.01% + 2 counts (per Fluke loop calibrators datasheet) |
| Output | Source/simulate mA; 24 V loop supply while measuring; 715 also sources 0–200 mV / 0–20 V |
| Supply | 9 V alkaline battery; 24 V internal loop supply |
| Process connection | Test leads / banana jacks (TL75 etc.) |
| Housing | Rugged handheld with holster (705/707) or 80-series DMM package (715) |
| Protection | Dust/splash resistant (715 EMI tolerant package) |
| Ambient temperature | Operating −10 to +55 °C |
| Display | Simultaneous mA and % of span; auto step/ramp; span check |
| Communication | 707 includes 250 Ω HART resistor mode |
| Approvals | CSA / IEC 61010 family safety markings per model; CE EMC |
| Notes | Family SKU covering Fluke 705/707/715 per Fluke Loop Calibrators Technical Data PDF on media.fluke.com. |