Time Electronics
Time Electronics 1010 DC Voltage Calibrator
Quote on request
No online payment · add lines to RFQ BOM
TE 1010: 0.01 μV–9.9999 V; ±0.02% (10 V/1 V); 10 ppm/h. RFQ.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Accuracy
±0.02 % of setting (10 V / 1 V ranges) with range floor terms; see datasheet for lower ranges
Type
Portable precision DC voltage calibrator
Output Range
0.01 μV to 9.9999 V in 5 ranges (10 V / 1 V / 100 mV / 10 mV / 1 mV)
Stability
10 ppm/hour typical
Max Current
25 mA (10 V/1 V/100 mV); up to 30 mA on 10 mV/1 mV ranges
Output Resistance
<0.1 Ω typical on higher ranges; 1 Ω on 10 mV/1 mV
Fits portable DC voltage calibration where you need a Time Electronics 1010—precision DC voltage calibrator from 0.01 μV to 9.9999 V across five ranges with ±0.02% of setting on 10 V / 1 V ranges and typical stability about 10 ppm/hour.
Key advantages
- Output — 0.01 μV to 9.9999 V in 5 ranges
- Accuracy — ±0.02% of setting on 10 V / 1 V ranges
- Stability — About 10 ppm/hour typical
- Form — Portable precision DC voltage calibrator
- Platform — Time Electronics 1010
Typical applications
- Meter voltage cal.
- Recorder / DMM checks.
- Lab DC source substitution.
Selection guide
- Range needed
- Load capability
- vs current sources 1021/1024
Common mistakes
- Overloading output.
- Ignoring lower-range floors.
- Warm-up skipped.
When to RFQ / what to tell us
- Accessories.
- Quantity, ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 42534 |
| Brand | Time Electronics |
| Model | 1010 DC Voltage Calibrator |
| Product type | Voltage Calibrator |
| Type | Portable precision DC voltage calibrator |
| Output range | 0.01 μV to 9.9999 V in 5 ranges (10 V / 1 V / 100 mV / 10 mV / 1 mV) |
| Accuracy | ±0.02 % of setting (10 V / 1 V ranges) with range floor terms; see datasheet for lower ranges |
| Stability | 10 ppm/hour typical |
Documents
FAQ
Q: Max output? A: 9.9999 V.
Q: Stability? A: About 10 ppm/hour typical.
Q: What should I send for a quote? A: Quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Accuracy | ±0.02 % of setting (10 V / 1 V ranges) with range floor terms; see datasheet for lower ranges |
| Type | Portable precision DC voltage calibrator |
| Output Range | 0.01 μV to 9.9999 V in 5 ranges (10 V / 1 V / 100 mV / 10 mV / 1 mV) |
| Stability | 10 ppm/hour typical |
| Max Current | 25 mA (10 V/1 V/100 mV); up to 30 mA on 10 mV/1 mV ranges |
| Output Resistance | <0.1 Ω typical on higher ranges; 1 Ω on 10 mV/1 mV |
| Power | Mains or internal rechargeable battery; ~40 hours typical between charges |
| Terminals | Safety terminals for 4 mm shrouded plugs / wires / spades; polarity normal/off/reverse |
| Construction | Compact portable case; optional carry case |
| Document | 1010 Data Sheet + 1010 User Manual |
| Application | Calibrate DC amplifiers, DVMs, data loggers, chart recorders; lab/field voltage source |
| Model Codes | 1010 DC Voltage Calibrator; optional C161/C114 calibration certificates |