Fluke 710 mA Loop Valve Tester
Fluke 710 mA loop valve tester with HART: 0–24 mA source/measure, 0–30 V DC, 0.01% ±2 counts. RFQ + selection help.
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Fits control-valve stroke and positioner checks where you need a handheld mA loop valve tester with HART — source/measure 0–24 mA, measure 0–30 V DC, 0.01% ± 2 counts, 24 V loop compliance, and ValveTrack software support for valve health quick-check.
Key advantages
- mA loop valve focus — Source/measure 0–24 mA with valve stroke workflows.
- 0.01% ± 2 counts — Accuracy class across listed ranges.
- Built-in HART — Simultaneous HART feedback interpretation with 24 V loop compliance.
- ValveTrack support — Valve health quick-check (good/marginal/bad) UI path.
Typical applications
- Control-valve stroke and positioner checks on 4–20 mA / HART loops.
- Maintenance rounds that need valve health good/marginal/bad documentation.
- Technicians who want a valve-focused tool instead of a full multi-function calibrator.
Selection guide
- Measuring range — Source/measure 0–24 mA; measure 0–30 V DC.
- Accuracy — 0.01% ± 2 counts, all ranges (per Fluke 710 technical data).
- Output — Precision mA source to stroke valves; simultaneous HART feedback; 24 V loop compliance.
- Supply — Internal battery; 24 V loop power capability.
- Communication — Built-in HART; ValveTrack software support.
- Display — Valve health quick-check (good/marginal/bad) + HART diagnostics UI.
- Form — Handheld Fluke process calibrator package.
Common mistakes
- Expecting full multi-function calibrator I/O (TC/RTD/pressure) — this SKU is mA loop valve tester with HART focus.
- Ignoring ValveTrack / HART feedback needs when documenting valve health good/marginal/bad.
- Assuming 24 V loop power without confirming loop loading on the positioner under test.
- Leaving environmental/IP confirmation blank when the site has unusual ambient limits — confirm against Fluke 710 environmental specifications.
When to RFQ / what to tell us
- Valve/positioner types under test and need for ValveTrack documentation.
- HART vs plain 4–20 mA stroke checks; quantity; ship-to.
- Any need for a broader multi-function calibrator instead.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 45942 |
| Brand | Fluke |
| Model | 710 |
| Product type | calibrator |
| Measuring range | mA loop valve tester with HART: source/measure 0–24 mA; measure 0–30 V DC |
| Accuracy | 0.01% ± 2 counts, all ranges (per Fluke 710 technical data) |
| Output signal | Precision mA source to stroke valves; simultaneous HART feedback interpretation; 24 V loop compliance |
| Supply voltage | Internal battery; 24 V loop power capability |
| Process connection | Test leads to 4–20 mA / HART valve positioner loops |
| Housing material | Handheld Fluke process calibrator package |
| IP rating | Per Fluke 710 environmental specifications |
| Ambient temperature | Per Fluke 710 technical data |
| Communication | Built-in HART communication; ValveTrack software support |
| Display | Valve health quick-check (good/marginal/bad) + HART diagnostics UI |
| Approvals | CE and safety markings per Fluke 710 documentation |
| Notes | Specs from Fluke 710 mA Loop Valve Tester Technical Data + product page/manual on fluke.com. |
Documents
FAQ
Q: What ranges? A: Source/measure 0–24 mA; measure 0–30 V DC; accuracy 0.01% ± 2 counts all ranges per Fluke 710 technical data.
Q: HART included? A: Built-in HART communication with valve health quick-check UI and ValveTrack software support.
Q: What should I send for a quote? A: Valve/HART needs, ValveTrack yes/no, quantity. Compatible with systems using Fluke 710 — we do not claim authorized-dealer status.
Links
| Parameter | Value |
|---|---|
| Measuring range | mA loop valve tester with HART: source/measure 0–24 mA; measure 0–30 V DC |
| Accuracy | 0.01% ± 2 counts, all ranges (per Fluke 710 technical data) |
| Output | Precision mA source to stroke valves; simultaneous HART feedback interpretation; 24 V loop compliance |
| Supply | Internal battery; 24 V loop power capability |
| Process connection | Test leads to 4–20 mA / HART valve positioner loops |
| Housing | Handheld Fluke process calibrator package |
| Protection | Per Fluke 710 environmental specifications |
| Ambient temperature | Per Fluke 710 technical data |
| Display | Valve health quick-check (good/marginal/bad) + HART diagnostics UI |
| Communication | Built-in HART communication; ValveTrack software support |
| Approvals | CE and safety markings per Fluke 710 documentation |
| Notes | Specs from Fluke 710 mA Loop Valve Tester Technical Data + product page/manual on fluke.com. |