Key parameters

Measuring range
mA loop valve tester with HART: source/measure 0–24 mA; measure 0–30 V DC
Accuracy
0.01% ± 2 counts, all ranges (per Fluke 710 technical data)
Output
Precision mA source to stroke valves; simultaneous HART feedback interpretation; 24 V loop compliance
Supply
Internal battery; 24 V loop power capability
Process connection
Test leads to 4–20 mA / HART valve positioner loops
Housing
Handheld Fluke process calibrator package
Download datasheet PDF

Fits control-valve stroke and positioner checks where you need a handheld mA loop valve tester with HART — source/measure 0–24 mA, measure 0–30 V DC, 0.01% ± 2 counts, 24 V loop compliance, and ValveTrack software support for valve health quick-check.

Key advantages

  • mA loop valve focus — Source/measure 0–24 mA with valve stroke workflows.
  • 0.01% ± 2 counts — Accuracy class across listed ranges.
  • Built-in HART — Simultaneous HART feedback interpretation with 24 V loop compliance.
  • ValveTrack support — Valve health quick-check (good/marginal/bad) UI path.

Typical applications

  • Control-valve stroke and positioner checks on 4–20 mA / HART loops.
  • Maintenance rounds that need valve health good/marginal/bad documentation.
  • Technicians who want a valve-focused tool instead of a full multi-function calibrator.

Selection guide

  • Measuring range — Source/measure 0–24 mA; measure 0–30 V DC.
  • Accuracy — 0.01% ± 2 counts, all ranges (per Fluke 710 technical data).
  • Output — Precision mA source to stroke valves; simultaneous HART feedback; 24 V loop compliance.
  • Supply — Internal battery; 24 V loop power capability.
  • Communication — Built-in HART; ValveTrack software support.
  • Display — Valve health quick-check (good/marginal/bad) + HART diagnostics UI.
  • Form — Handheld Fluke process calibrator package.

Common mistakes

  • Expecting full multi-function calibrator I/O (TC/RTD/pressure) — this SKU is mA loop valve tester with HART focus.
  • Ignoring ValveTrack / HART feedback needs when documenting valve health good/marginal/bad.
  • Assuming 24 V loop power without confirming loop loading on the positioner under test.
  • Leaving environmental/IP confirmation blank when the site has unusual ambient limits — confirm against Fluke 710 environmental specifications.

When to RFQ / what to tell us

  1. Valve/positioner types under test and need for ValveTrack documentation.
  2. HART vs plain 4–20 mA stroke checks; quantity; ship-to.
  3. Any need for a broader multi-function calibrator instead.

Request a Quote · Get selection help

Specs

SpecValue
SKU45942
BrandFluke
Model710
Product typecalibrator
Measuring rangemA loop valve tester with HART: source/measure 0–24 mA; measure 0–30 V DC
Accuracy0.01% ± 2 counts, all ranges (per Fluke 710 technical data)
Output signalPrecision mA source to stroke valves; simultaneous HART feedback interpretation; 24 V loop compliance
Supply voltageInternal battery; 24 V loop power capability
Process connectionTest leads to 4–20 mA / HART valve positioner loops
Housing materialHandheld Fluke process calibrator package
IP ratingPer Fluke 710 environmental specifications
Ambient temperaturePer Fluke 710 technical data
CommunicationBuilt-in HART communication; ValveTrack software support
DisplayValve health quick-check (good/marginal/bad) + HART diagnostics UI
ApprovalsCE and safety markings per Fluke 710 documentation
NotesSpecs from Fluke 710 mA Loop Valve Tester Technical Data + product page/manual on fluke.com.

Documents

FAQ

Q: What ranges? A: Source/measure 0–24 mA; measure 0–30 V DC; accuracy 0.01% ± 2 counts all ranges per Fluke 710 technical data.

Q: HART included? A: Built-in HART communication with valve health quick-check UI and ValveTrack software support.

Q: What should I send for a quote? A: Valve/HART needs, ValveTrack yes/no, quantity. Compatible with systems using Fluke 710 — we do not claim authorized-dealer status.

Links

ParameterValue
Measuring rangemA loop valve tester with HART: source/measure 0–24 mA; measure 0–30 V DC
Accuracy0.01% ± 2 counts, all ranges (per Fluke 710 technical data)
OutputPrecision mA source to stroke valves; simultaneous HART feedback interpretation; 24 V loop compliance
SupplyInternal battery; 24 V loop power capability
Process connectionTest leads to 4–20 mA / HART valve positioner loops
HousingHandheld Fluke process calibrator package
ProtectionPer Fluke 710 environmental specifications
Ambient temperaturePer Fluke 710 technical data
DisplayValve health quick-check (good/marginal/bad) + HART diagnostics UI
CommunicationBuilt-in HART communication; ValveTrack software support
ApprovalsCE and safety markings per Fluke 710 documentation
NotesSpecs from Fluke 710 mA Loop Valve Tester Technical Data + product page/manual on fluke.com.