Fluke

Fluke 62 MAX+/323/1AC Electrical Test Kit

SKU · 38966 · 62 MAX+/323/1AC Kit · Brand: Fluke
Available
Quote on request
No online payment · add lines to RFQ BOM

Kit: 62 MAX+ IR; 323 True-RMS clamp; 1AC II NCV; C115 case. RFQ qty.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Approvals
IP54 (62 MAX+); CAT III 600 V / CAT IV 300 V (323); CAT IV 1000 V (1AC-II); CE
Kit Contents
62 MAX+ IR thermometer + 323 true-rms clamp + 1AC-II VoltAlert + C115 soft case
Ir Temperature Range
62 MAX+: −30 to 650 °C (−22 to 1202 °F)
Ir Accuracy
≥0 °C: ±1.0 °C or ±1.0% of reading (whichever greater); degraded accuracy below 0 °C per DS
Ir Optical
12:1 D:S; dual rotating lasers; spectral 8–14 µm; emissivity 0.10–1.00; response <300 ms (95%)
Ir Ruggedness
IP54; 3 m drop; size 175×85×75 mm; weight 255 g; 1×AA battery (~8 h with laser/backlight)
Download datasheet PDF

Fits general electrical and mechanical walk-around testing where you need the Fluke 62 MAX+/323/1AC kit—62 MAX+ IR thermometer, 323 True-RMS clamp meter, 1AC II VoltAlert, test leads, and a C115 soft case.

Key advantages

  • IR — 62 MAX+: −30…650 °C; 12:1; dual laser
  • Clamp — 323 True-RMS: 400 A AC; 600 V AC/DC class
  • NCV — 1AC II VoltAlert non-contact voltage detector
  • Case — C115 soft carrying case
  • Leads — Clamp meter test leads included

Typical applications

  • Facility electrical rounds.
  • HVAC electrical + temperature checks.
  • Maintenance tech starter kits.

Selection guide

  • Spare batteries
  • Quantity of kits
  • Calibration options

Common mistakes

  • Expecting DC current on 323 (AC clamp focus).
  • Ignoring CAT ratings per tool.
  • IR emissivity errors on shiny metals.

When to RFQ / what to tell us

  1. Quantity.
  2. Ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU38966
BrandFluke
Model62 MAX+/323/1AC
Product typeElectrical Test Kit
TypeIR thermometer + clamp meter + NCV kit (Fluke 62 MAX+/323/1AC)
IR62 MAX+: −30…650 °C; 12:1 D:S; dual laser
Clamp323 True-RMS clamp: 400 A AC; 600 V AC/DC class
NCV1AC II VoltAlert non-contact voltage detector
CaseC115 soft carrying case; test leads included

Documents

FAQ

Q: What is in the kit? A: 62 MAX+, 323 clamp, 1AC II, leads, and C115 case.

Q: Clamp current? A: 400 A AC class on the 323.

Q: What should I send for a quote? A: Quantity, ship-to.

Links

ParameterValue
ApprovalsIP54 (62 MAX+); CAT III 600 V / CAT IV 300 V (323); CAT IV 1000 V (1AC-II); CE
Kit Contents62 MAX+ IR thermometer + 323 true-rms clamp + 1AC-II VoltAlert + C115 soft case
Ir Temperature Range62 MAX+: −30 to 650 °C (−22 to 1202 °F)
Ir Accuracy≥0 °C: ±1.0 °C or ±1.0% of reading (whichever greater); degraded accuracy below 0 °C per DS
Ir Optical12:1 D:S; dual rotating lasers; spectral 8–14 µm; emissivity 0.10–1.00; response <300 ms (95%)
Ir RuggednessIP54; 3 m drop; size 175×85×75 mm; weight 255 g; 1×AA battery (~8 h with laser/backlight)
Clamp Range323: AC current to 400.0 A; AC/DC voltage to 600 V; resistance; continuity
Clamp AccuracyAC current 2.0% ±5 digits (45–65 Hz); CAT IV 300 V / CAT III 600 V; IP30 non-operating
Clamp Size Weight207×75×34 mm; 265 g; 2×AAA
Ncv Range1AC-II: nominally 90–1000 V AC, 45–405 Hz; CAT IV 1000 V; IP40; 2×AAA
Form FactorHandheld electrical/HVAC test kit with soft case