Image unavailable
Image unavailable
Endress+Hauser
Endress+Hauser Proline Promag W 300 Electromagnetic Flow Meter
Quote on request
No online payment · add lines to RFQ BOM
E+H Promag W 300: water magmeter; compact Proline 300; HART/fieldbus; IP66/67. RFQ.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Measuring range
Volume flow; DN sizes per TI01414D nominal-diameter tables
Accuracy
Volume flow accuracy classes per TI01414D (standard and optional high-accuracy)
Accuracy % FS
0.5
Output
4–20 mA HART; pulse/frequency/switch; optional fieldbuses/Ethernet on Promag 300 transmitter
Supply
DC or AC transmitter supply options per TI
Process connection
Flanged and water-industry process connections per TI01414D
Fits water-industry volume flow where you need an Endress+Hauser Proline Promag W 300. Compact electromagnetic flowmeter with flanged and water-industry connections, 4–20 mA HART plus pulse/frequency/switch outputs, optional fieldbuses/Ethernet on the Proline 300 transmitter, and IP66/67 transmitter protection.
Key advantages
- Platform — Compact Promag W 300
- Outputs — 4–20 mA HART; pulse/frequency/switch
- Fieldbus — Optional Ethernet/fieldbuses
- IP — Transmitter IP66/67; sensor IP67/IP68 options
- Use — Water-industry conductive liquids
Typical applications
- Water distribution.
- Wastewater plants.
- Utility magmeters.
Selection guide
- DN / liner / electrodes
- I/O / fieldbus
- IP68 sensor need
Common mistakes
- Non-conductive media.
- Wrong grounding.
- Missing inlet run.
When to RFQ / what to tell us
- DN/liner/I/O.
- Quantity, ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 46825 |
| Brand | Endress+Hauser |
| Model | Proline Promag W 300 |
| Product type | Electromagnetic Flow Meter |
| Measuring range | Volume flow; DN sizes by order (water-industry Promag W 300) |
| Accuracy | Volume flow accuracy classes; 0.5% FS class option field present |
| Output signal | 4–20 mA HART; pulse/frequency/switch; optional fieldbuses/Ethernet on Promag 300 transmitter |
| Supply voltage | DC or AC transmitter supply options |
| Process connection | Flanged and water-industry process connections |
| IP rating | IP66/67 transmitter; sensor IP67/IP68 options |
| Communication | HART; optional fieldbuses/Ethernet as ordered |
| Mounting | Inline electromagnetic sensor with compact Promag 300 transmitter |
Documents
FAQ
Q: Platform? A: Proline Promag W 300 compact.
Q: Outputs? A: 4–20 mA HART + pulse/frequency/switch.
Q: What should I send for a quote? A: DN/liner/I/O, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Measuring range | Volume flow; DN sizes per TI01414D nominal-diameter tables |
| Accuracy | Volume flow accuracy classes per TI01414D (standard and optional high-accuracy) |
| Accuracy % FS | 0.5 |
| Output | 4–20 mA HART; pulse/frequency/switch; optional fieldbuses/Ethernet on Promag 300 transmitter |
| Supply | DC or AC transmitter supply options per TI |
| Process connection | Flanged and water-industry process connections per TI01414D |
| Electrical connection | Cable entries on compact Promag 300 transmitter |
| Wetted parts | Liner and electrode materials for water applications per order code |
| Housing | Compact transmitter housing; sensor housing per TI |
| Protection | IP66/67 transmitter; sensor IP67/IP68 options |
| Media temperature | Per liner process temperature tables in TI |
| Ambient temperature | Transmitter ambient limits per TI |
| Pressure type | other |
| Display | Local display on Promag 300 transmitter |
| Communication | HART; optional fieldbuses/Ethernet as ordered |
| Approvals | Drinking water approvals options; ATEX/IECEx options; Heartbeat Technology |
| Hazardous area | Ex approvals by order code |
| Mounting | Inline electromagnetic sensor with compact Promag 300 transmitter |
| Notes | Specs from Endress+Hauser TI01414D (Promag W 300). Compact water magmeter family. |
| Overpressure Limit | Pressure ratings by flange class / size in TI |