Walchem

Walchem IX Series Metering Pumps

SKU · 46812 · IX Series Metering Pumps · Brand: Walchem
Available
Quote on request
No online payment · add lines to RFQ BOM

Walchem IX: direct-drive diaphragm; 0.002–79.2 GPH; to 247 PSI; 1000:1; ±1%. RFQ.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Accuracy
±1% repeatability
Type
Digitally controlled direct-drive diaphragm metering pumps (IX-B / IX-C / IX-D)
Capacity Range
0.002–79.2 GPH (7.5 mL/H–300 L/H) model-dependent
Max Pressure
Up to 247 PSI (17 bar) on IX-B007 class
Turndown Ratio
Up to 1000:1 via brushless DC motor speed control
Energy
Up to ~70% energy savings vs conventional mechanical diaphragm pumps
Download datasheet PDF

Fits digitally controlled chemical feed where you need a Walchem IX Series pump. Direct-drive diaphragm metering family (IX-B/C/D) spanning about 0.002–79.2 GPH with pressures to 247 PSI on IX-B007 class, up to 1000:1 turndown via brushless DC speed control and ±1% repeatability.

Key advantages

  • Capacity — About 0.002–79.2 GPH
  • Pressure — Up to 247 PSI (IX-B007 class)
  • Turndown — Up to 1000:1
  • Repeatability — ±1%
  • Drive — Brushless DC digital control

Typical applications

  • High-turndown chemical feed.
  • Water treatment metering.
  • Process dosing skids.

Selection guide

  • IX-B/C/D size
  • GPH / PSI
  • Control I/O

Common mistakes

  • Undersized pressure.
  • Ignoring model capacity band.
  • Wrong wetted materials.

When to RFQ / what to tell us

  1. Model/GPH/PSI.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU46812
BrandWalchem
ModelIX Series Metering Pumps
Product typeMetering Pump
TypeDigitally controlled direct-drive diaphragm metering pumps (IX-B / IX-C / IX-D)
Capacity range0.002–79.2 GPH (7.5 mL/H–300 L/H) model-dependent
Max pressureUp to 247 PSI (17 bar) on IX-B007 class
Turndown ratioUp to 1000:1 via brushless DC motor speed control
Accuracy±1% repeatability
EnergyUp to ~70% energy savings vs conventional mechanical diaphragm pumps

Documents

FAQ

Q: Turndown? A: Up to 1000:1.

Q: Repeatability? A: ±1%.

Q: What should I send for a quote? A: Model/GPH/PSI, quantity, ship-to.

Links

ParameterValue
Accuracy±1% repeatability
TypeDigitally controlled direct-drive diaphragm metering pumps (IX-B / IX-C / IX-D)
Capacity Range0.002–79.2 GPH (7.5 mL/H–300 L/H) model-dependent
Max PressureUp to 247 PSI (17 bar) on IX-B007 class
Turndown RatioUp to 1000:1 via brushless DC motor speed control
EnergyUp to ~70% energy savings vs conventional mechanical diaphragm pumps
Ingress ProtectionIP65
ControlPulse / analog (0–20 mA) inputs; pulse/stop/analog outputs; batch & proportional modes
Liquid Temperature0–50 °C (TC/TE); 0–80 °C (S6); indoor use 0–50 °C
Suction LiftMax dry suction lift ~6.5 ft (2 m)