Image unavailable
Image unavailable
Fluke
Fluke 726 Precision Process Calibrator
Quote on request
No online payment · add lines to RFQ BOM
Precision multifunction calibrator; 0.01% V/mA; 24 V loop. RFQ + selection help.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Accuracy class
0.01 % measurement/source (voltage/mA class per OEM DS)
Channels
Two independent channels; measure, source and view simultaneously
Voltage
0–100 mV / 0–20 V source; 0–30 V measure
Current
0–24 mA measure/source; 24 V loop supply
Temperature
Thermocouples J K T E L N U C BP XK B R S; RTDs Cu10 Ni120 Pt100/200/500/1000
Resistance
5 Ω to 4000 Ω
Fits precision process calibration where you need a Fluke 726 measuring and sourcing mA, V, RTD, TC, frequency and pressure with 0.01% class V/mA accuracy and 24 V loop supply.
Key advantages
- Accuracy — DC V 0.01% + 2 mV (30 V class); mA 0.01% + 2 µA
- Loop — 24 V loop power
- Pressure — Fluke 750P modules; from 0.025% class
- Functions — Dual channel; error calculation
- Signals — Measure/source mA, V, RTD, TC, frequency, pressure
Typical applications
- Precision transmitter calibration.
- Loop power + mA checks.
- Pressure cal with 750P modules.
Selection guide
- Accuracy need — 0.01% vs 725 class
- Pressure modules — Ranges
- HART — Not documenting HART (see 754)
- Dual channel — Simultaneous measure/source
Common mistakes
- Expecting built-in HART documenting.
- Wrong pressure module range.
- Ignoring 24 V loop current budget.
When to RFQ / what to tell us
- Modules/accessories; quantity; ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 26455 |
| Brand | Fluke |
| Model | 726 |
| Product type | Process Calibrator |
| Type | Precision multifunction process calibrator |
| Accuracy DC V | 0.01% + 2 mV (30 V range class) |
| Accuracy mA | 0.01% + 2 µA |
| Loop supply | 24 V loop power |
| Pressure | Supports Fluke 750P modules; pressure accuracy from 0.025% class |
| Functions | Measure/source mA, V, RTD, TC, frequency, pressure |
| Extra | Error calculation; dual channel |
Documents
FAQ
Q: V/mA accuracy? A: About 0.01% class on DC V and mA.
Q: HART? A: 726 is precision multifunction; use 754 for documenting HART.
Q: What should I send for a quote? A: Modules, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Accuracy class | 0.01 % measurement/source (voltage/mA class per OEM DS) |
| Channels | Two independent channels; measure, source and view simultaneously |
| Voltage | 0–100 mV / 0–20 V source; 0–30 V measure |
| Current | 0–24 mA measure/source; 24 V loop supply |
| Temperature | Thermocouples J K T E L N U C BP XK B R S; RTDs Cu10 Ni120 Pt100/200/500/1000 |
| Resistance | 5 Ω to 4000 Ω |
| Frequency | 2.0 CPM to 15 kHz class source/measure; totalizer / pulse-train modes |
| Pressure | Measure/source via Fluke 700Pxx / 750Pxx pressure modules (pump required) |
| Hart Mode | Inserts 250 Ω resistor in mA path for HART instruments |
| Memory | Store up to 8 calibration results; transmitter error % calculation |
| Operating Temperature | −10 °C to 55 °C |
| Size Weight | 200 × 96 × 47 mm; 650 g |
| Power | Four AA alkaline; ~25 hours typical |
| Family | Fluke 726 Precision Multifunction Process Calibrator |