Image unavailable
Image unavailable
Fluke
Fluke 754 Documenting Process Calibrator
Quote on request
No online payment · add lines to RFQ BOM
HART documenting calibrator; mA/V/RTD/TC; IP52. RFQ + selection help.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Family
Fluke 753/754 Documenting Process Calibrators
Hart
754 includes HART communication (vs 753)
Functions
Source/measure/simulate mA, V, RTD, TC, frequency, pressure (with modules)
Temperature Spec Window
Specs apply +18 to +28 °C after 5 min warmup; damping on for measurement specs
Documenting
Automated as-found/as-left procedures; documenting calibrator
Power
Rechargeable battery pack (OEM family)
Fits documenting HART calibration routes where you need a Fluke 754 with built-in HART, measure/source process signals, and IP52 field packaging.
Key advantages
- HART — Built-in HART communication
- Accuracy — DC V 0.02% + 0.005 mV (100 mV, 1 yr); mA 0.01% + 5 µA
- Measure — Up to 300 V DC measure class
- Ingress — IP52
- Workflow — Documenting calibrator with pressure-module support
Typical applications
- HART transmitter as-found/as-left.
- Documented calibration routes.
- Field mA/V/RTD/TC/pressure work.
Selection guide
- HART need — Built-in vs separate communicator
- Pressure modules — Ranges
- Documentation software — Route workflow
- IP52 — Field environment
Common mistakes
- Buying 726 when HART documenting is required.
- Missing pressure module for DP transmitters.
- Ignoring battery/runtime on long routes.
When to RFQ / what to tell us
- Modules/software; quantity; ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 26456 |
| Brand | Fluke |
| Model | 754 |
| Product type | Documenting Process Calibrator |
| Type | Documenting process calibrator with HART |
| HART | Built-in HART communication |
| Accuracy DC V | 0.02% + 0.005 mV (100 mV, 1 yr class) |
| Accuracy mA | 0.01% + 5 µA |
| Measure range | Up to 300 V DC measure class |
| Ingress | IP52 |
| Functions | Documenting cal; measure/source process signals; pressure modules |
Documents
FAQ
Q: HART built-in? A: Yes — documenting process calibrator with HART.
Q: Ingress? A: IP52.
Q: What should I send for a quote? A: Modules/software, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Family | Fluke 753/754 Documenting Process Calibrators |
| Hart | 754 includes HART communication (vs 753) |
| Functions | Source/measure/simulate mA, V, RTD, TC, frequency, pressure (with modules) |
| Temperature Spec Window | Specs apply +18 to +28 °C after 5 min warmup; damping on for measurement specs |
| Documenting | Automated as-found/as-left procedures; documenting calibrator |
| Power | Rechargeable battery pack (OEM family) |
| Safety | CAT safety ratings per Fluke 753/754 product specifications |
| Revision | Product Specifications Rev. 11, Nov 2022 / Aug 2023 |
| Form Factor | Handheld documenting process calibrator |
| Applications | Transmitter calibration, loop checkout, HART device configuration (754) |