Image unavailable
Image unavailable
Fluke
Fluke 789 ProcessMeter
Quote on request
No online payment · add lines to RFQ BOM
DMM + mA source/simulate; 1000 V; 24 V loop. RFQ + selection help.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Product
Fluke 789 ProcessMeter — DMM + mA loop calibrator
Loop Power
24 V loop power supply; HART loop-power mode (789 vs 787B)
Functions
Source/simulate mA; measure V/mA/resistance; troubleshooting DMM
Safety
Safety-rated digital multimeter platform
Family
787B and 789 ProcessMeter technical data
Form Factor
Compact handheld ProcessMeter
Fits combined DMM and loop work where you need a Fluke 789 ProcessMeter measuring to 1000 V with mA source/simulate and a 24 V loop supply.
Key advantages
- DMM — Voltage to 1000 V; DC V accuracy 0.1% + 1 LSD
- Loop — mA source and simulate; 24 V loop supply
- Display — Dual-display ProcessMeter
- Safety — CAT III / CAT IV industrial ratings per OEM
- Form — Handheld ProcessMeter for techs who carry one tool
Typical applications
- 4–20 mA loop source while metering.
- Transmitter simulate checks.
- Industrial DMM + loop combo rounds.
Selection guide
- Loop supply — 24 V need
- mA simulate vs source — Wiring style
- CAT rating — Panel environment
- Vs separate calibrator — Accuracy vs convenience
Common mistakes
- Expecting documenting HART (see 754).
- Ignoring CAT rating at the panel.
- Overloading mA output into wrong burden.
When to RFQ / what to tell us
- Leads/accessories; quantity; ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 30265 |
| Brand | Fluke |
| Model | 789 |
| Product type | ProcessMeter / Multimeter |
| Type | ProcessMeter — DMM with mA source/simulate |
| Voltage | Up to 1000 V |
| Accuracy DC V | 0.1% + 1 LSD |
| mA source | mA source and simulate; 24 V loop supply |
| Display | Dual display ProcessMeter |
| Safety | CAT III / CAT IV industrial ratings per OEM |
Documents
FAQ
Q: Loop supply? A: Yes — 24 V loop supply with mA source/simulate.
Q: Max voltage? A: Up to 1000 V.
Q: What should I send for a quote? A: Accessories, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Product | Fluke 789 ProcessMeter — DMM + mA loop calibrator |
| Loop Power | 24 V loop power supply; HART loop-power mode (789 vs 787B) |
| Functions | Source/simulate mA; measure V/mA/resistance; troubleshooting DMM |
| Safety | Safety-rated digital multimeter platform |
| Family | 787B and 789 ProcessMeter technical data |
| Form Factor | Compact handheld ProcessMeter |
| Applications | Loop calibration, HART-powered transmitters, plant maintenance |
| Oem Images | media.fluke.com product photography + datasheet pages |
| Documentation | Fluke 787B and 789 ProcessMeter Technical Data |