Fluke

Fluke 28 II Ex Intrinsically Safe Multimeter

SKU · 30272 · 28 II Ex · Brand: Fluke
Available
Quote on request
No online payment · add lines to RFQ BOM

Fluke 28 II Ex IS True-RMS DMM: Class I Div 1 / ATEX Zone 1-2, IP67, CAT III 1000 V / CAT IV 600 V. RFQ + selection help.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Dc Voltage
0.1 mV to 1000 V; +/-(0.05% + 1)
Ac Voltage
0.1 mV to 1000 V true-RMS; +/-(0.7% + 4)
Current
0.1 uA to 10 A AC/DC (Ex zones require reduced measurements)
Resistance
0.1 ohm to 50 Mohm; +/-(0.2% + 1)
Capacitance
10 nF to 9999 uF
Frequency
0.5 Hz to 199.99 kHz
Download datasheet PDF

Fits hazardous-area electrical troubleshooting where you need an intrinsically safe True-RMS DMM listed for Class I Div 1 / ATEX Zone 1–2, with IP67 protection and CAT III 1000 V / CAT IV 600 V category ratings.

Key advantages

  • IS-listed family — Class I Div 1 / ATEX Zone 1–2 Ex ia IIC T4 Gb / IECEx.
  • True-RMS to 1000 V / 10 A class — Ex zones may require reduced measurements; confirm site limits.
  • IP67 + ~3 m drop — Field ruggedness with holster.
  • CAT III 1000 V / CAT IV 600 V — Plus resistance, capacitance, frequency, temperature, VSD filter.

Typical applications

  • Electrical troubleshooting inside Class I Div 1 or ATEX Zone 1–2 areas.
  • Plants that standardize on an IS True-RMS DMM with IP67 packaging.
  • VFD and fine-resolution checks where VSD / high-resolution modes matter.

Selection guide

  • Intrinsic safety — Class I Div 1 / ATEX Zone 1–2 Ex ia IIC T4 Gb / IECEx listed family.
  • Voltage / current — True-RMS to 1000 V / 10 A class (Ex zones may require reduced measurements).
  • Protection — IP67; drop-tested to about 3 m with holster.
  • Safety category — CAT III 1000 V / CAT IV 600 V.
  • Functions — Resistance, capacitance, frequency, temperature; high-resolution mode; VSD low-pass filter.
  • Form — Handheld IS DMM with reversible red holster.

Common mistakes

  • Ordering a non-Ex DMM for Zone 1 / Div 1 work — 28 II Ex is the IS-listed family.
  • Ignoring that Ex zones may require reduced measurements vs the 1000 V / 10 A class headline.
  • Treating IP67 as a substitute for the IS certificate — both matter; confirm site approval.
  • Skipping VSD / high-resolution needs when VFD or fine readings are the duty.

When to RFQ / what to tell us

  1. Required IS marks (Class I Div 1 / ATEX Zone 1–2 Ex ia IIC T4 Gb / IECEx) for the site.
  2. Voltage/current class and whether Ex-zone reduced measurements apply.
  3. Quantity, ship-to, holster/temperature-probe needs.

Request a Quote · Get selection help

Specs

SpecValue
SKU30272
BrandFluke
Model28 II Ex Intrinsically Safe Multimeter
Product typeintrinsicallysafemultimeter
TypeFluke 28 II Ex intrinsically safe true-RMS digital multimeter
Intrinsic safetyClass I Div 1 / ATEX Zone 1-2 Ex ia IIC T4 Gb / IECEx listed family
Voltage / currentTrue-RMS to 1000 V / 10 A class (Ex zones may require reduced measurements)
ProtectionIP67; drop-tested to about 3 m with holster
Safety categoryCAT III 1000 V / CAT IV 600 V
FunctionsResistance, capacitance, frequency, temperature; high-resolution mode; VSD low-pass filter
Form factorHandheld IS DMM with reversible red holster
DocumentFluke 28 II Ex datasheet + UM + media.fluke.com OEM product photos

Documents

FAQ

Q: Which hazardous-area marks are listed? A: Class I Div 1 / ATEX Zone 1-2 Ex ia IIC T4 Gb / IECEx listed family — confirm the exact certificate against site policy.

Q: Is IP67 enough for Zone 1 without the Ex listing? A: No — IP67 and the IS listing are both on the extract; Ex approval is required for hazardous-area use.

Q: What should I send for a quote? A: Required zone/division marks, voltage class, quantity, ship-to. Compatible with systems using Fluke 28 II Ex — we do not claim authorized-dealer status.

Links

ParameterValue
Dc Voltage0.1 mV to 1000 V; +/-(0.05% + 1)
Ac Voltage0.1 mV to 1000 V true-RMS; +/-(0.7% + 4)
Current0.1 uA to 10 A AC/DC (Ex zones require reduced measurements)
Resistance0.1 ohm to 50 Mohm; +/-(0.2% + 1)
Capacitance10 nF to 9999 uF
Frequency0.5 Hz to 199.99 kHz
Temperature-200 to +1090 C (-328 to +1994 F)
Display Counts6000 / 19999 high-resolution mode
Ingress ProtectionIP67; drop-tested to 3 m with holster
Safety CategoryCAT III 1000 V / CAT IV 600 V
Intrinsic SafetyClass I Div 1 Groups ABCD T4; ATEX II 2G Ex ia IIC T4 Gb; IECEx Ex ia IIC T4 Gb
Battery LifeThree AAA Ex-approved; ~400 h typical without backlight
Form FactorHandheld intrinsically safe true-RMS DMM with reversible holster
FamilyFluke 28 II Ex