Fluke

Fluke 8808A Digital Multimeter

SKU · 30282 · 8808A · Brand: Fluke
Available
Quote on request
No online payment · add lines to RFQ BOM

5.5-digit bench DMM; 0.015% DC V; RS-232/USB. RFQ + selection help.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Display
VFD dual-reading multi-segment display
Resolution
5.5 digit
Basic Vdc Accuracy
0.01% (extended specs) / 0.015% (product page class)
Vdc Range
200 mV to 1000 V; max resolution 1 µV
Vac Range
200 mV to 750 V; 20 Hz to 100 kHz
Resistance
200 Ω to 100 MΩ; 2×4-wire ohms; 1 mΩ max resolution
Download datasheet PDF

Fits bench precision metering where you need a Fluke 8808A 5.5-digit DMM covering 200 mV–1000 V DC with ±(0.015% reading + 0.003% range) accuracy and RS-232/USB connectivity.

Key advantages

  • Digits — 5.5-digit bench multimeter
  • DC V — 200 mV to 1000 V
  • Accuracy — ±(0.015% of reading + 0.003% of range)
  • I/O — RS-232; USB via adapter
  • Functions — V, I, Ω, continuity, diode; dual display

Typical applications

  • Production bench functional test.
  • Calibration-support DMM.
  • Automated RS-232/USB measurements.

Selection guide

  • Digits/accuracy — 5.5-digit class enough?
  • Interface — RS-232 vs USB adapter
  • Current shunts/ranges — DUT needs
  • Bench footprint — Lab layout

Common mistakes

  • Expecting 6.5-digit metrology class.
  • Missing USB adapter when PC logging.
  • Wrong input terminals for current.

When to RFQ / what to tell us

  1. Interface adapters; quantity; ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU30282
BrandFluke
Model8808A
Product typeBench Multimeter
Type5.5-digit bench digital multimeter
DC voltage200 mV to 1000 V DC
Accuracy DC V±(0.015% of reading + 0.003% of range)
InterfacesRS-232; USB via adapter
FunctionsV, I, Ω, continuity, diode; dual display
Form factorBench instrument

Documents

FAQ

Q: Accuracy? A: ±(0.015% of reading + 0.003% of range) on DC V.

Q: Interface? A: RS-232; USB via adapter.

Q: What should I send for a quote? A: Accessories, quantity, ship-to.

Links

ParameterValue
DisplayVFD dual-reading multi-segment display
Resolution5.5 digit
Basic Vdc Accuracy0.01% (extended specs) / 0.015% (product page class)
Vdc Range200 mV to 1000 V; max resolution 1 µV
Vac Range200 mV to 750 V; 20 Hz to 100 kHz
Resistance200 Ω to 100 MΩ; 2×4-wire ohms; 1 mΩ max resolution
Adc Range200 µA to 10 A
Aac Range20 mA to 10 A
Frequency20 Hz to 1 MHz
FunctionsSix setup preset buttons; Hi/Lo limit compare Pass/Fail; dB/dBm; Fluke 45 remote emulation
InterfacesRS-232; USB with optional adapter
Size Weight88 × 217 × 297 mm; 2.1 kg (4.6 lb)
SafetyEN 61010-1 / UL 61010-1 / CSA designed compliance
WarrantyThree years