Panametrics
Panametrics XMO2pro Oxygen Analyzer
Quote on request
No online payment · add lines to RFQ BOM
Paramagnetic %O2 analyzer; ±1% span; dual mA + Modbus. RFQ + selection help.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Accuracy
±1% of span (±2% for 0–1% range)
Analyzer Type
Paramagnetic (magnetic wind) percent oxygen analyzer
Zero Stability
±1% of span per month (±2% for 0–1% range)
Response Time
Standard ~70 s; Fast-Response option ~15 s
Measurement Ranges
0–1% to 0–100% O2 (typical spans)
Analog Output
Two isolated 4–20 mA, 550 Ω max
Fits percent oxygen measurement where you need an XMO2pro paramagnetic (magnetic wind) analyzer with dual isolated 4–20 mA, Modbus, and field-mount weatherproof/Ex enclosure options.
Key advantages
- Principle — Paramagnetic (magnetic wind) percent oxygen analyzer
- Accuracy — ±1% of span (±2% for 0–1% range); zero stability ±1%/month class
- Response — Standard ~70 s; Fast-Response option ~15 s
- I/O — Two isolated 4–20 mA; Modbus
- Enclosure — Weatherproof / explosion-proof / flameproof field-mount options
Typical applications
- Process percent oxygen monitoring.
- Inerting and combustion-related %O2 (application-dependent).
- Sites needing Modbus plus dual mA in field-mount packages.
Selection guide
- Span — 0–1% to 0–100% O2 typical spans
- Response option — Standard vs Fast-Response
- Enclosure / Ex — Weatherproof vs explosion-proof/flameproof
- Sample — 50–1000 cc/min; −5 to 55 °C sample temperature typical
Common mistakes
- Ordering 0–1% span without accepting ±2% of span accuracy class.
- Ignoring sample conditioning (flow, particulates, condensables).
- Omitting Ex enclosure when the area is classified.
When to RFQ / what to tell us
- O2 span; response option.
- Enclosure/Ex; sample conditions.
- Quantity and ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 191282 |
| Brand | Panametrics |
| Model | XMO2pro Oxygen Analyzer |
| Product type | Oxygen Analyzer |
| Analyzer type | Paramagnetic (magnetic wind) percent oxygen analyzer |
| Accuracy | ±1% of span (±2% for 0–1% range) |
| Zero stability | ±1% of span per month (±2% for 0–1% range) |
| Response time | Standard ~70 s; Fast-Response option ~15 s |
| Measurement ranges | 0–1% to 0–100% O2 (typical spans) |
| Analog output | Two isolated 4–20 mA, 550 Ω max |
| Digital output | Modbus |
| Power | 24 VDC ±4 VDC, 2 A |
| Sample flow | 50–1000 cc/min (0.1–2.0 SCFH) |
| Sample temperature | –5 to 55 °C typical |
| Enclosure | Weatherproof / explosion-proof / flameproof field-mount |
| Weight | Aluminum ~4.5 kg; stainless ~11 kg |
Documents
FAQ
Q: What sensing principle? A: Paramagnetic (magnetic wind) percent oxygen.
Q: What outputs? A: Two isolated 4–20 mA and Modbus.
Q: What should I send for a quote? A: Span/response/enclosure, sample conditions, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Accuracy | ±1% of span (±2% for 0–1% range) |
| Analyzer Type | Paramagnetic (magnetic wind) percent oxygen analyzer |
| Zero Stability | ±1% of span per month (±2% for 0–1% range) |
| Response Time | Standard ~70 s; Fast-Response option ~15 s |
| Measurement Ranges | 0–1% to 0–100% O2 (typical spans) |
| Analog Output | Two isolated 4–20 mA, 550 Ω max |
| Digital Output | Modbus |
| Power | 24 VDC ±4 VDC, 2 A |
| Sample Flow | 50–1000 cc/min (0.1–2.0 SCFH) |
| Sample Temperature | –5 to 55 °C typical |
| Enclosure | Weatherproof / explosion-proof / flameproof field-mount |
| Weight | Aluminum ~4.5 kg; stainless ~11 kg |
| Functional Safety | SIL 2 by design (optional) |
| Datasheet | PANA079DS Rev. 13 (06/2026) |