Image unavailable
Image unavailable
Rosemount
Rosemount Oxymitter 4000 In-Situ Oxygen Transmitter
Quote on request
No online payment · add lines to RFQ BOM
Oxymitter 4000: ZrO2 O2; 0–10% to 0–40%; ±0.75% rdg; T90 <8 s. RFQ.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Measuring range
Net O2 0–10% to 0–40% (Xi electronics offer 0–50%)
Accuracy
±0.75% of reading or ±0.05% O2, whichever is greater
Type
In-situ zirconium oxide oxygen transmitter for combustion flue gas (Oxymitter 4000)
Lowest Detectable Limit
0.02% O2
Response Time
Initial <3 s; T90 <8 s (process-dependent)
Process Temperature
Up to 1300 °F (700 °C); higher with optional bypass/jacket
Fits combustion oxygen trim where you need a Rosemount Oxymitter 4000—in-situ ZrO2 transmitter with net O2 ranges from 0–10% to 0–40% (Xi to 0–50%), ±0.75% of reading or ±0.05% O2 accuracy, and T90 under about 8 seconds.
Key advantages
- Range — Net O2 0–10% to 0–40% (Xi to 0–50%)
- Accuracy — ±0.75% rdg or ±0.05% O2 (whichever greater)
- LDL — 0.02% O2
- Response — Initial <3 s; T90 <8 s (process-dependent)
- Use — In-situ flue-gas oxygen
Typical applications
- Power boiler O2 control.
- Process furnace trim.
- Combustion safety/efficiency loops.
Selection guide
- Probe / Xi electronics
- Calibration accessories
- Hazardous-area options
Common mistakes
- Confusing with 6888 platform options.
- Inadequate probe length.
- Missing cal gas.
When to RFQ / what to tell us
- Probe, electronics.
- Quantity, ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 38932 |
| Brand | Rosemount |
| Model | Oxymitter 4000 |
| Product type | Oxygen Analyzer |
| Type | In-situ zirconium oxide oxygen transmitter for combustion flue gas (Oxymitter 4000) |
| Measuring range | Net O2 0–10% to 0–40% (Xi electronics offer 0–50%) |
| Accuracy | ±0.75% of reading or ±0.05% O2, whichever is greater |
| Lowest detectable limit | 0.02% O2 |
| Response time | Initial <3 s; T90 <8 s (process-dependent) |
Documents
FAQ
Q: Accuracy? A: ±0.75% of reading or ±0.05% O2, whichever greater.
Q: T90? A: Under about 8 seconds (process-dependent).
Q: What should I send for a quote? A: Probe/electronics, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Measuring range | Net O2 0–10% to 0–40% (Xi electronics offer 0–50%) |
| Accuracy | ±0.75% of reading or ±0.05% O2, whichever is greater |
| Type | In-situ zirconium oxide oxygen transmitter for combustion flue gas (Oxymitter 4000) |
| Lowest Detectable Limit | 0.02% O2 |
| Response Time | Initial <3 s; T90 <8 s (process-dependent) |
| Process Temperature | Up to 1300 °F (700 °C); higher with optional bypass/jacket |
| Probe Lengths | 18 in to 18 ft insertion options |
| Housing | Type 4X (IP65/IP66) transmitter housing on probe or remote |
| Communications | 4–20 mA HART; FOUNDATION Fieldbus options; wireless via THUM |
| Diagnostics | Advanced sensor diagnostics; calibration-recommended alarm |
| Repairable | Fully field-repairable cell and heater/thermocouple |
| Document | PDS 00813-0100-4340 Rev AB + RM 00809-0100-4340 |