Image unavailable
Image unavailable
Panametrics
Panametrics oxy.IQ Oxygen Transmitter
Quote on request
No online payment · add lines to RFQ BOM
oxy.IQ: O2 transmitter; 0–10 ppm to 0–50% O2 class. RFQ range.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Accuracy
±1% of range at calibration (±2% for 0–10 ppmv OX-1/OX-2)
Hazardous area
IS Class I Div 1 / ATEX Zone 0; flameproof Ex d IP66 option
Transmitter Type
Two-wire loop-powered galvanic fuel-cell O2 transmitter
Repeatability
±1% of range (±2% for 0–10 ppmv)
Resolution
±0.1% of range
Ppm Ranges
0–10 to 0–10,000 ppmv O2 (sensor-dependent)
Fits process oxygen measurement where you need a Panametrics oxy.IQ—oxygen transmitter covering ranges from about 0–10 ppm up to 0–50% O₂ depending on configuration.
Key advantages
- Range class — 0–10 ppm up to 0–50% O₂
- Platform — Panametrics oxy.IQ transmitter
- Use — Process / industrial oxygen
- Form — Dedicated O2 transmitter
- Pairing — Sample system / probe options class
Typical applications
- Inerting oxygen monitoring.
- Process gas O2 control.
- Packaged analyzer panels.
Selection guide
- ppm vs % range
- Sample system
- Output / alarms
Common mistakes
- Wrong range for expected O2.
- Contaminated sample without filtration.
- Ignoring sample pressure limits.
When to RFQ / what to tell us
- Range, sample system.
- Quantity, ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 39384 |
| Brand | Panametrics |
| Model | oxy.IQ |
| Product type | Oxygen Transmitter |
| Type | Oxygen transmitter (Panametrics oxy.IQ) |
| Range | 0–10 ppm up to 0–50% O₂ class |
| Feature | Process oxygen measurement transmitter |
Documents
FAQ
Q: Range span? A: From about 0–10 ppm up to 0–50% O₂ class.
Q: Brand? A: Panametrics (Baker Hughes).
Q: What should I send for a quote? A: Range/sample, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Accuracy | ±1% of range at calibration (±2% for 0–10 ppmv OX-1/OX-2) |
| Hazardous area | IS Class I Div 1 / ATEX Zone 0; flameproof Ex d IP66 option |
| Transmitter Type | Two-wire loop-powered galvanic fuel-cell O2 transmitter |
| Repeatability | ±1% of range (±2% for 0–10 ppmv) |
| Resolution | ±0.1% of range |
| Ppm Ranges | 0–10 to 0–10,000 ppmv O2 (sensor-dependent) |
| Percent Ranges | 0–1% to 0–50% O2 |
| Power | 24–28 VDC at 50 mA |
| Sample Pressure | Vented for cal/op; max ~10 psig sample |
| Sample Flow | ~500 cc/min recommended |
| Sensor Temperature | 0 to 45 °C |
| Height | 10.4 cm with integrated display/keypad |
| Datasheet | PANA024DS Rev. 13 |