Analytical Industries GPR-1200 Portable Oxygen Analyzer

SKU · 46243 · GPR-1200 · Brand: Analytical Industries Inc (AII)
Available
Quote on request
No online payment · add lines to RFQ BOM

AII GPR-1200: portable ppm O₂; 0–10 to 0–1000 ppmV; LDL 0.05; ~30 day battery. RFQ.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Accuracy
<2 % of selected range at constant conditions
Approvals
General purpose or hazardous-area (ATEX/IECEx/cMETus/UKEx) options
Type
Portable ppm oxygen analyzer (GPR-1200) with sample/bypass valve
Measurement Range
0…10 / 0…100 / 0…1,000 ppmV; 0…1 % and 0…25 % for calibration
Resolution
0.01 ppmV; LDL 0.05 ppmV
Battery Life
Up to 30 days
Download datasheet PDF

Fits portable ppm oxygen checks where you need an Analytical Industries GPR-1200. Portable analyzer with ranges 0…10 / 0…100 / 0…1,000 ppmV plus 0…1% and 0…25% for calibration, LDL 0.05 ppmV, 0…1 V analog output, integral data logging and battery life up to about 30 days.

Key advantages

  • Ranges — 0…10/100/1000 ppmV + % cal ranges
  • LDL — 0.05 ppmV; resolution 0.01 ppmV
  • Output — 0…1 V; integral logging
  • Battery — Up to ~30 days
  • Sample — 0.5…1 LPM; 5…30 psi

Typical applications

  • Field ppm O₂ checks.
  • Portable inerting verification.
  • Spot-check oxygen surveys.

Selection guide

  • Range set
  • Sample/bypass use
  • Logging needs

Common mistakes

  • Air leaks at ppm.
  • Wrong sample pressure.
  • Dead battery in field.

When to RFQ / what to tell us

  1. Range/kit.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU46243
BrandAnalytical Industries Inc
ModelGPR-1200
Product typePortable Oxygen Analyzer
TypePortable ppm oxygen analyzer (GPR-1200) with sample/bypass valve
Measurement range0…10 / 0…100 / 0…1,000 ppmV; 0…1 % and 0…25 % for calibration
Accuracy<2 % of selected range at constant conditions
Resolution0.01 ppmV; LDL 0.05 ppmV
Output0…1 V analog; integral measurement data logging
Battery lifeUp to 30 days
SampleFlow 0.5…1 LPM (1…2 SCFH); sample pressure 5…30 psi (0.3…2 bar); T90 <2 min

Documents

FAQ

Q: LDL? A: 0.05 ppmV.

Q: Battery? A: Up to ~30 days.

Q: What should I send for a quote? A: Range/kit, quantity, ship-to.

Links

ParameterValue
Accuracy<2 % of selected range at constant conditions
ApprovalsGeneral purpose or hazardous-area (ATEX/IECEx/cMETus/UKEx) options
TypePortable ppm oxygen analyzer (GPR-1200) with sample/bypass valve
Measurement Range0…10 / 0…100 / 0…1,000 ppmV; 0…1 % and 0…25 % for calibration
Resolution0.01 ppmV; LDL 0.05 ppmV
Battery LifeUp to 30 days
SampleFlow 0.5…1 LPM (1…2 SCFH); sample pressure 5…30 psi (0.3…2 bar); T90 <2 min
SensorsGPR-12-333 (inert), XLT-12-333 (CO2/acid), GPR-12-333-H (H2/He)
DocumentPST/AII GPR-1200 Datasheet PST-DS-3200-00 + GPR Portables User Manual