Image unavailable
Image unavailable
Laurel Electronics
Laurel Laureate Ohm Panel Meter
Quote on request
No online payment · add lines to RFQ BOM
1/8 DIN resistance panel meter. 20 Ω–200 kΩ; ±0.01% of range. RFQ + engineer selection help.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Accuracy
±0.01% of range ± 2 counts at 25 °C
Display
5-digit 14.2 mm (0.56") red or green LED
Type
1/8 DIN Laureate digital ohmmeter / resistance panel meter
Ranges
Five jumper-selectable ranges 20.000 Ω to 200.00 kΩ; factory specials 2 Ω / 2 MΩ / 20 MΩ
Resolution
1 mΩ on 20 Ω range (0.1 mΩ on 2 Ω special)
Connection
2-, 3- or 4-wire with lead-resistance compensation
Fits panel resistance measurement where you need a 1/8 DIN Laureate ohmmeter with jumper-selectable ranges and optional Ethernet/relay outputs.
Key advantages
- Ranges — Five jumper-selectable ranges 20.000 Ω to 200.00 kΩ; factory specials 2 Ω / 2 MΩ / 20 MΩ
- Accuracy — ±0.01% of range ± 2 counts at 25 °C
- Lead compensation — 2-, 3- or 4-wire with lead-resistance compensation
- Update rate — Up to 60 conversions per second
- Front rating — 1/8 DIN; NEMA 4X (IP65) from front when panel mounted
Typical applications
- Panel-mounted ohm/resistance indication on production or lab benches.
- 2-/3-/4-wire resistance loops needing lead-resistance compensation.
- Optional analog 4–20 mA / 0–10 V or Ethernet/serial tie-in to PLC/SCADA.
Selection guide
- Range — Five jumper-selectable ranges 20.000 Ω to 200.00 kΩ; factory specials 2 Ω / 2 MΩ / 20 MΩ
- Accuracy / resolution — ±0.01% of range ± 2 counts at 25 °C; 1 mΩ on 20 Ω range (0.1 mΩ on 2 Ω special)
- Wiring — 2-, 3- or 4-wire with lead-resistance compensation
- Power — Universal 85–264 Vac; optional 10–48 Vdc / 12–32 Vac
- I/O options — Ethernet/USB/RS232/RS485; dual/quad relays; isolated analog 4–20 mA / 0–10 V
- Display — 5-digit 14.2 mm (0.56") red or green LED
Common mistakes
- Long 2-wire leads without 3-/4-wire compensation on low-ohm spans.
- Ordering 20 Ω when the duty needs the 2 Ω factory special (0.1 mΩ).
- Assuming relays/Ethernet are included — they are Laureate options.
When to RFQ / what to tell us
- Resistance span and preferred range (incl. factory specials).
- 2-/3-/4-wire preference.
- Power (Vac vs Vdc option).
- Relay/analog/serial-Ethernet options; LED color; quantity; ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 10 |
| Brand | Laurel Electronics |
| Model | Laureate Ohm Panel Meter |
| Product type | Resistance Panel Meter |
| Type | 1/8 DIN Laureate digital ohmmeter / resistance panel meter |
| Ranges | Five jumper-selectable ranges 20.000 Ω to 200.00 kΩ; factory specials 2 Ω / 2 MΩ / 20 MΩ |
| Resolution | 1 mΩ on 20 Ω range (0.1 mΩ on 2 Ω special) |
| Accuracy | ±0.01% of range ± 2 counts at 25 °C |
| Connection | 2-, 3- or 4-wire with lead-resistance compensation |
| Update rate | Up to 60 conversions per second |
| Display | 5-digit 14.2 mm (0.56") red or green LED |
| Power | Universal 85–264 Vac; optional 10–48 Vdc / 12–32 Vac |
| Enclosure | 1/8 DIN; NEMA 4X (IP65) from front when panel mounted |
| Options | Ethernet/USB/RS232/RS485; dual/quad relays; isolated analog 4–20 mA / 0–10 V |
| Feature | Front-panel USB-C setup; factory digital calibration in EEPROM |
Documents
FAQ
Q: Published accuracy? A: ±0.01% of range ± 2 counts at 25 °C per Laurel ohms datasheet.
Q: 4–20 mA available? A: Isolated analog 4–20 mA / 0–10 V is an option — state it on the RFQ.
Q: What should I send for a quote? A: Range, wiring, power, I/O options, quantity.
Links
| Parameter | Value |
|---|---|
| Accuracy | ±0.01% of range ± 2 counts at 25 °C |
| Display | 5-digit 14.2 mm (0.56") red or green LED |
| Type | 1/8 DIN Laureate digital ohmmeter / resistance panel meter |
| Ranges | Five jumper-selectable ranges 20.000 Ω to 200.00 kΩ; factory specials 2 Ω / 2 MΩ / 20 MΩ |
| Resolution | 1 mΩ on 20 Ω range (0.1 mΩ on 2 Ω special) |
| Connection | 2-, 3- or 4-wire with lead-resistance compensation |
| Update Rate | Up to 60 conversions per second |
| Power | Universal 85–264 Vac; optional 10–48 Vdc / 12–32 Vac |
| Enclosure | 1/8 DIN; NEMA 4X (IP65) from front when panel mounted |
| Options | Ethernet/USB/RS232/RS485; dual/quad relays; isolated analog 4–20 mA / 0–10 V |
| Feature | Front-panel USB-C setup; factory digital calibration in EEPROM |