E+H iTHERM ModuLine TM111 Temperature Sensor
E+H iTHERM ModuLine TM111 RTD/TC with QuickSens; −200…+1100 °C; to 75 bar; ATEX/IECEx/CSA options. RFQ + selection help.
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Fits process temperature points that need modular RTD/TC with iTHERM QuickSens fast response, Dual Seal options, measuring span to −200…+1100 °C, pressure to 75 bar, and ATEX/IECEx/CSA explosion-protection codes.
Key advantages
- Measuring range — −200 to +1100 °C (−328 to +2012 °F) depending on sensor type; Pt100 WW extended −200 to +600 °C; TC to 1100 °C.
- Fast response — Pt100 Class A / Class AA; TC standard/special class per IEC; iTHERM QuickSens t50 0.5 s / t90 1.5 s (ø6 mm).
- Sensor design — Modular RTD/TC with iTHERM QuickSens fast-response insert options; Dual Seal technology.
- Process pressure — Up to 75 bar (1088 psi) to +200 °C for standard TF/QuickSens Pt100; 50 bar to +400 °C for other sensors.
- Approvals — ATEX; IECEx; CSA (explosion protection options).
Typical applications
- Hazardous-area temperature measurement needing ATEX/IECEx/CSA thermometer codes.
- Fast-response process control where QuickSens t50 0.5 s / t90 1.5 s (ø6 mm) matters.
- Extended RTD/TC spans — Pt100 WW to +600 °C; TC options to 1100 °C.
- Higher process pressure duties up to 75 bar (sensor/temperature dependent).
Selection guide
- Sensor / QuickSens — Confirm Pt100 WW vs QuickSens ø6 mm vs TC before RFQ.
- Output — Direct-wired or iTEMP head transmitter 4–20 mA / HART / IO-Link.
- Process connection — Threads, compression fittings, and welded variants per ModuLine configurator.
- Pressure vs temperature — Standard TF/QuickSens Pt100 to 75 bar at +200 °C; 50 bar to +400 °C for other sensors — lock both.
- Ex marks — ATEX; IECEx; CSA (explosion protection options) — state zone/division on the RFQ.
Common mistakes
- Ordering TM101 when Ex or QuickSens is required — TM111 is the advanced/Ex ModuLine path.
- Ignoring pressure derating with temperature — 75 bar applies to standard TF/QuickSens Pt100 to +200 °C.
- Leaving Dual Seal / connection type blank when the process needs welded or compression variants.
- Assuming every insert hits 1100 °C — family max depends on sensor type (Pt100 WW extended −200…+600 °C; TC to 1100 °C).
When to RFQ / what to tell us
- Sensor type (QuickSens Pt100 vs WW vs TC), insert diameter/length, and response-time need.
- Process connection, media T/P, Ex code (ATEX/IECEx/CSA), and iTEMP 4–20 mA/HART/IO-Link yes/no.
- Quantity, ship-to, Dual Seal or special connection notes.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 140960 |
| Brand | Endress+Hauser |
| Model | iTHERM ModuLine TM111 |
| Product type | rtdtcthermometer |
| Measuring Range | −200 to +1100 °C (−328 to +2012 °F) depending on sensor type; Pt100 WW extended −200 to +600 °C; TC to 1100 °C |
| Accuracy | Pt100 Class A / Class AA; TC standard/special class per IEC; iTHERM QuickSens t50 0.5 s / t90 1.5 s (ø6 mm) |
| Sensor Type | Modular RTD/TC with iTHERM QuickSens fast-response insert options; Dual Seal technology |
| Output Signal | Direct-wired or iTEMP head transmitter 4–20 mA / HART / IO-Link |
| Process Pressure | Up to 75 bar (1088 psi) to +200 °C for standard TF/QuickSens Pt100; 50 bar to +400 °C for other sensors |
| Ingress Protection | Up to IP66 / partly IP68 depending on design |
| Process Connection | Threads, compression fittings, and welded variants per ModuLine configurator |
| Approvals | ATEX; IECEx; CSA (explosion protection options) |
| Notes | Specs from E+H TI01445TEN (iTHERM ModuLine TM111) + BA01915TEN. |
Documents
FAQ
Q: When do I need TM111 instead of TM101? A: When you need QuickSens response, higher T/P options, Dual Seal, or ATEX/IECEx/CSA marks — TM101 is the non-hazardous basic offering.
Q: How fast is QuickSens? A: iTHERM QuickSens lists t50 0.5 s / t90 1.5 s for ø6 mm inserts — confirm diameter on the ordered string.
Q: What should I send for a quote? A: Sensor type, T/P, Ex code, connection, transmitter, quantity. Compatible with systems using E+H iTHERM ModuLine TM111 — we do not claim authorized-dealer status.
Links
| Parameter | Value |
|---|---|
| Measuring range | −200 to +1100 °C (−328 to +2012 °F) depending on sensor type; Pt100 WW extended −200 to +600 °C; TC to 1100 °C |
| Accuracy | Pt100 Class A / Class AA; TC standard/special class per IEC; iTHERM QuickSens t50 0.5 s / t90 1.5 s (ø6 mm) |
| Output | Direct-wired or iTEMP head transmitter 4–20 mA / HART / IO-Link |
| Process connection | Threads, compression fittings, and welded variants per ModuLine configurator |
| Approvals | ATEX; IECEx; CSA (explosion protection options) |
| Sensor type | Modular RTD/TC with iTHERM QuickSens fast-response insert options; Dual Seal technology |
| Notes | Specs from E+H TI01445TEN (iTHERM ModuLine TM111) + BA01915TEN. |
| Process Pressure | Up to 75 bar (1088 psi) to +200 °C for standard TF/QuickSens Pt100; 50 bar to +400 °C for other sensors |
| Ingress Protection | Up to IP66 / partly IP68 depending on design |