Key parameters

Measuring range
−200 to +1100 °C (−328 to +2012 °F) depending on sensor type; Pt100 WW extended −200 to +600 °C; TC to 1100 °C
Accuracy
Pt100 Class A / Class AA; TC standard/special class per IEC; iTHERM QuickSens t50 0.5 s / t90 1.5 s (ø6 mm)
Output
Direct-wired or iTEMP head transmitter 4–20 mA / HART / IO-Link
Process connection
Threads, compression fittings, and welded variants per ModuLine configurator
Approvals
ATEX; IECEx; CSA (explosion protection options)
Sensor type
Modular RTD/TC with iTHERM QuickSens fast-response insert options; Dual Seal technology
Download datasheet PDF

Fits process temperature points that need modular RTD/TC with iTHERM QuickSens fast response, Dual Seal options, measuring span to −200…+1100 °C, pressure to 75 bar, and ATEX/IECEx/CSA explosion-protection codes.

Key advantages

  • Measuring range — −200 to +1100 °C (−328 to +2012 °F) depending on sensor type; Pt100 WW extended −200 to +600 °C; TC to 1100 °C.
  • Fast response — Pt100 Class A / Class AA; TC standard/special class per IEC; iTHERM QuickSens t50 0.5 s / t90 1.5 s (ø6 mm).
  • Sensor design — Modular RTD/TC with iTHERM QuickSens fast-response insert options; Dual Seal technology.
  • Process pressure — Up to 75 bar (1088 psi) to +200 °C for standard TF/QuickSens Pt100; 50 bar to +400 °C for other sensors.
  • Approvals — ATEX; IECEx; CSA (explosion protection options).

Typical applications

  • Hazardous-area temperature measurement needing ATEX/IECEx/CSA thermometer codes.
  • Fast-response process control where QuickSens t50 0.5 s / t90 1.5 s (ø6 mm) matters.
  • Extended RTD/TC spans — Pt100 WW to +600 °C; TC options to 1100 °C.
  • Higher process pressure duties up to 75 bar (sensor/temperature dependent).

Selection guide

  • Sensor / QuickSens — Confirm Pt100 WW vs QuickSens ø6 mm vs TC before RFQ.
  • Output — Direct-wired or iTEMP head transmitter 4–20 mA / HART / IO-Link.
  • Process connection — Threads, compression fittings, and welded variants per ModuLine configurator.
  • Pressure vs temperature — Standard TF/QuickSens Pt100 to 75 bar at +200 °C; 50 bar to +400 °C for other sensors — lock both.
  • Ex marks — ATEX; IECEx; CSA (explosion protection options) — state zone/division on the RFQ.

Common mistakes

  • Ordering TM101 when Ex or QuickSens is required — TM111 is the advanced/Ex ModuLine path.
  • Ignoring pressure derating with temperature — 75 bar applies to standard TF/QuickSens Pt100 to +200 °C.
  • Leaving Dual Seal / connection type blank when the process needs welded or compression variants.
  • Assuming every insert hits 1100 °C — family max depends on sensor type (Pt100 WW extended −200…+600 °C; TC to 1100 °C).

When to RFQ / what to tell us

  1. Sensor type (QuickSens Pt100 vs WW vs TC), insert diameter/length, and response-time need.
  2. Process connection, media T/P, Ex code (ATEX/IECEx/CSA), and iTEMP 4–20 mA/HART/IO-Link yes/no.
  3. Quantity, ship-to, Dual Seal or special connection notes.

Request a Quote · Get selection help

Specs

SpecValue
SKU140960
BrandEndress+Hauser
ModeliTHERM ModuLine TM111
Product typertdtcthermometer
Measuring Range−200 to +1100 °C (−328 to +2012 °F) depending on sensor type; Pt100 WW extended −200 to +600 °C; TC to 1100 °C
AccuracyPt100 Class A / Class AA; TC standard/special class per IEC; iTHERM QuickSens t50 0.5 s / t90 1.5 s (ø6 mm)
Sensor TypeModular RTD/TC with iTHERM QuickSens fast-response insert options; Dual Seal technology
Output SignalDirect-wired or iTEMP head transmitter 4–20 mA / HART / IO-Link
Process PressureUp to 75 bar (1088 psi) to +200 °C for standard TF/QuickSens Pt100; 50 bar to +400 °C for other sensors
Ingress ProtectionUp to IP66 / partly IP68 depending on design
Process ConnectionThreads, compression fittings, and welded variants per ModuLine configurator
ApprovalsATEX; IECEx; CSA (explosion protection options)
NotesSpecs from E+H TI01445TEN (iTHERM ModuLine TM111) + BA01915TEN.

Documents

FAQ

Q: When do I need TM111 instead of TM101? A: When you need QuickSens response, higher T/P options, Dual Seal, or ATEX/IECEx/CSA marks — TM101 is the non-hazardous basic offering.

Q: How fast is QuickSens? A: iTHERM QuickSens lists t50 0.5 s / t90 1.5 s for ø6 mm inserts — confirm diameter on the ordered string.

Q: What should I send for a quote? A: Sensor type, T/P, Ex code, connection, transmitter, quantity. Compatible with systems using E+H iTHERM ModuLine TM111 — we do not claim authorized-dealer status.

Links

ParameterValue
Measuring range−200 to +1100 °C (−328 to +2012 °F) depending on sensor type; Pt100 WW extended −200 to +600 °C; TC to 1100 °C
AccuracyPt100 Class A / Class AA; TC standard/special class per IEC; iTHERM QuickSens t50 0.5 s / t90 1.5 s (ø6 mm)
OutputDirect-wired or iTEMP head transmitter 4–20 mA / HART / IO-Link
Process connectionThreads, compression fittings, and welded variants per ModuLine configurator
ApprovalsATEX; IECEx; CSA (explosion protection options)
Sensor typeModular RTD/TC with iTHERM QuickSens fast-response insert options; Dual Seal technology
NotesSpecs from E+H TI01445TEN (iTHERM ModuLine TM111) + BA01915TEN.
Process PressureUp to 75 bar (1088 psi) to +200 °C for standard TF/QuickSens Pt100; 50 bar to +400 °C for other sensors
Ingress ProtectionUp to IP66 / partly IP68 depending on design