Watlow

Watlow RF Style RTD

SKU · 23835 · RF Style RTD · Brand: Watlow
Available
Quote on request
No online payment · add lines to RFQ BOM

Flexible MI RTD; metal transition; −200 to 650 °C; Class A/B. RFQ + selection help.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Measuring range
Family −200 to 650 °C (−328 to 1200 °F)
Accuracy
DIN Class A (±0.06%) or Class B (±0.12%) options
Process connection
Thermowell / compression fitting ready (application dependent)
Sensor type
Style RF flexible mineral-insulated RTD with metal transition
Element
100 Ω two- or three-wire RTD elements typical
Sheath Diameter
0.125 / 0.188 / 0.250 in sheath diameter options
Download datasheet PDF

Fits flexible mineral-insulated RTD routing where you need a Watlow Style RF with metal transition, coiled-spring strain relief, and −200 to 650 °C family range.

Key advantages

  • Style — RF flexible MI RTD with metal transition
  • Range — −200 to 650 °C (−328 to 1200 °F)
  • Accuracy — DIN Class A (±0.06%) or Class B (±0.12%)
  • Sheath — 0.125 / 0.188 / 0.250 in SS options
  • Transition — SS transitions with 260 °C epoxy; coiled-spring strain relief

Typical applications

  • Process piping and exhaust.
  • Plastics and food equipment.
  • Tight-space MI routing.

Selection guide

  • Class A/B — Accuracy
  • OD — 0.125 / 0.188 / 0.250 in
  • Element — 100 Ω 2- or 3-wire typical
  • Fittings — Compression/thermowell

Common mistakes

  • Bending beyond MI minimum radius.
  • Exceeding 260 °C at epoxy transition.
  • Wrong wire count vs transmitter.

When to RFQ / what to tell us

  1. Class, OD, length, wire count.
  2. Quantity and ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU23835
BrandWatlow
ModelRF Style RTD
Product typeRTD
Sensor typeStyle RF flexible mineral-insulated RTD with metal transition
Measuring rangeFamily −200 to 650 °C (−328 to 1200 °F)
AccuracyDIN Class A (±0.06%) or Class B (±0.12%) options
Element100 Ω two- or three-wire RTD elements typical
Sheath diameter0.125 / 0.188 / 0.250 in sheath diameter options
Sheath materialStainless steel sheath (style-dependent)
TransitionStainless-steel transitions filled with 260 °C epoxy; coiled-spring strain relief
ConstructionFlexible MI cable construction for routing in tight spaces
InsulationInsulation resistance exceeds DIN-IEC-751
ApplicationsProcess piping, exhaust, plastics, food equipment, general industrial temperature
FeaturesFlexible MI with coiled spring strain relief at transition

Documents

FAQ

Q: What is Style RF? A: Flexible MI RTD with metal transition and spring strain relief.

Q: Sheath diameters? A: 0.125 / 0.188 / 0.250 in options.

Q: What should I send for a quote? A: Class/OD/length, quantity, ship-to.

Links

ParameterValue
Measuring rangeFamily −200 to 650 °C (−328 to 1200 °F)
AccuracyDIN Class A (±0.06%) or Class B (±0.12%) options
Process connectionThermowell / compression fitting ready (application dependent)
Sensor typeStyle RF flexible mineral-insulated RTD with metal transition
Element100 Ω two- or three-wire RTD elements typical
Sheath Diameter0.125 / 0.188 / 0.250 in sheath diameter options
Sheath MaterialStainless steel sheath (style-dependent)
TransitionStainless-steel transitions filled with 260 °C epoxy; coiled-spring strain relief
ConstructionFlexible MI cable construction for routing in tight spaces
Insulation StandardInsulation resistance exceeds DIN-IEC-751
TransmitterOptional head-mounted transmitter assemblies in related Watlow styles
ApplicationsProcess piping, exhaust, plastics, food equipment, general industrial temperature
Special FeaturesFlexible MI with coiled spring strain relief at transition