Key parameters

Measuring range
Pt100 −200 to +600 °C; StrongSens −50 to +500 °C; QuickSens −50 to +200 °C
Accuracy
Class A or Class AA per IEC 60751
Process connection
Clamp ISO 2852, DIN 11851/11864, Varivent, Ingold, SMS, Neumo, weld-in, and more
Protection
Up to IP69K
Approvals
ATEX; IECEx; CSA; FM; EAC Ex; JPN Ex; NEPSI; UKCA; SIL (transmitter)
Response Time
QuickSens t90 ≈ 1.5 s; StrongSens t90 ≈ 9.5 s (configuration dependent)
Download datasheet PDF

Fits modular process RTD measurement where you need an Endress+Hauser iTHERM ModuLine TM411. Pt100 thermometer spanning −200 to +600 °C (StrongSens −50…+500 °C; QuickSens −50…+200 °C) with Class A/AA accuracy, QuickSens t90 ≈ 1.5 s, process pressure to 40 bar at 20 °C and protection up to IP69K.

Key advantages

  • Sensor — Pt100 QuickSens / StrongSens / WW
  • Accuracy — Class A or AA (IEC 60751)
  • Response — QuickSens t90 ≈ 1.5 s
  • Pressure — Up to 40 bar at 20 °C
  • IP — Up to IP69K

Typical applications

  • Process RTD assemblies.
  • Fast-response temperature.
  • Modular iTHERM loops.

Selection guide

  • QuickSens vs StrongSens
  • Class A/AA
  • Thermowell / insert

Common mistakes

  • Wrong sensor for T band.
  • Ignoring pressure derate.
  • Missing IP69K washdown need.

When to RFQ / what to tell us

  1. Sensor/well/class.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU47158
BrandEndress+Hauser
ModeliTHERM TM411
Product typeRTD Thermometer
Measuring rangePt100 −200 to +600 °C; StrongSens −50 to +500 °C; QuickSens −50 to +200 °C
AccuracyClass A or Class AA per IEC 60751
Response timeQuickSens t90 ≈ 1.5 s; StrongSens t90 ≈ 9.5 s (configuration dependent)
Process pressureUp to 40 bar (580 psi) at 20 °C
IP ratingUp to IP69K
SensorThin-film RTD QuickSens/StrongSens or 2×Pt100 wire-wound inserts; MI flexible inserts

Documents

FAQ

Q: QuickSens t90? A: About 1.5 s.

Q: Max pressure? A: 40 bar at 20 °C.

Q: What should I send for a quote? A: Sensor/well/class, quantity, ship-to.

Links

ParameterValue
Measuring rangePt100 −200 to +600 °C; StrongSens −50 to +500 °C; QuickSens −50 to +200 °C
AccuracyClass A or Class AA per IEC 60751
Process connectionClamp ISO 2852, DIN 11851/11864, Varivent, Ingold, SMS, Neumo, weld-in, and more
ProtectionUp to IP69K
ApprovalsATEX; IECEx; CSA; FM; EAC Ex; JPN Ex; NEPSI; UKCA; SIL (transmitter)
Response TimeQuickSens t90 ≈ 1.5 s; StrongSens t90 ≈ 9.5 s (configuration dependent)
Process PressureUp to 40 bar (580 psi) at 20 °C
SensorThin-film RTD QuickSens/StrongSens or 2×Pt100 wire-wound inserts; MI flexible inserts
ThermowellOptional thermowell / Tee / elbow; OD 6.0 / 9.0 / 12.7 mm; 1.4435 / 316L
Surface FinishRa 0.76 / 0.38 µm; electropolished options
TransmitterHead transmitter 4–20 mA, HART, PROFIBUS PA, FOUNDATION Fieldbus; Bluetooth parametrization
Hygiene3-A; EHEDG; ASME BPE; FDA; TSE
Special FeaturesiTHERM QuickNeck tool-free insert removal; modular hygienic metric design for food & life sciences