E+H iTHERM TM411: Pt100; QuickSens t90≈1.5 s; Class A/AA; to 40 bar; IP69K. RFQ.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Measuring range
Pt100 −200 to +600 °C; StrongSens −50 to +500 °C; QuickSens −50 to +200 °C
Accuracy
Class A or Class AA per IEC 60751
Process connection
Clamp ISO 2852, DIN 11851/11864, Varivent, Ingold, SMS, Neumo, weld-in, and more
Protection
Up to IP69K
Approvals
ATEX; IECEx; CSA; FM; EAC Ex; JPN Ex; NEPSI; UKCA; SIL (transmitter)
Response Time
QuickSens t90 ≈ 1.5 s; StrongSens t90 ≈ 9.5 s (configuration dependent)
Fits modular process RTD measurement where you need an Endress+Hauser iTHERM ModuLine TM411. Pt100 thermometer spanning −200 to +600 °C (StrongSens −50…+500 °C; QuickSens −50…+200 °C) with Class A/AA accuracy, QuickSens t90 ≈ 1.5 s, process pressure to 40 bar at 20 °C and protection up to IP69K.
Key advantages
- Sensor — Pt100 QuickSens / StrongSens / WW
- Accuracy — Class A or AA (IEC 60751)
- Response — QuickSens t90 ≈ 1.5 s
- Pressure — Up to 40 bar at 20 °C
- IP — Up to IP69K
Typical applications
- Process RTD assemblies.
- Fast-response temperature.
- Modular iTHERM loops.
Selection guide
- QuickSens vs StrongSens
- Class A/AA
- Thermowell / insert
Common mistakes
- Wrong sensor for T band.
- Ignoring pressure derate.
- Missing IP69K washdown need.
When to RFQ / what to tell us
- Sensor/well/class.
- Quantity, ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 47158 |
| Brand | Endress+Hauser |
| Model | iTHERM TM411 |
| Product type | RTD Thermometer |
| Measuring range | Pt100 −200 to +600 °C; StrongSens −50 to +500 °C; QuickSens −50 to +200 °C |
| Accuracy | Class A or Class AA per IEC 60751 |
| Response time | QuickSens t90 ≈ 1.5 s; StrongSens t90 ≈ 9.5 s (configuration dependent) |
| Process pressure | Up to 40 bar (580 psi) at 20 °C |
| IP rating | Up to IP69K |
| Sensor | Thin-film RTD QuickSens/StrongSens or 2×Pt100 wire-wound inserts; MI flexible inserts |
Documents
FAQ
Q: QuickSens t90? A: About 1.5 s.
Q: Max pressure? A: 40 bar at 20 °C.
Q: What should I send for a quote? A: Sensor/well/class, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Measuring range | Pt100 −200 to +600 °C; StrongSens −50 to +500 °C; QuickSens −50 to +200 °C |
| Accuracy | Class A or Class AA per IEC 60751 |
| Process connection | Clamp ISO 2852, DIN 11851/11864, Varivent, Ingold, SMS, Neumo, weld-in, and more |
| Protection | Up to IP69K |
| Approvals | ATEX; IECEx; CSA; FM; EAC Ex; JPN Ex; NEPSI; UKCA; SIL (transmitter) |
| Response Time | QuickSens t90 ≈ 1.5 s; StrongSens t90 ≈ 9.5 s (configuration dependent) |
| Process Pressure | Up to 40 bar (580 psi) at 20 °C |
| Sensor | Thin-film RTD QuickSens/StrongSens or 2×Pt100 wire-wound inserts; MI flexible inserts |
| Thermowell | Optional thermowell / Tee / elbow; OD 6.0 / 9.0 / 12.7 mm; 1.4435 / 316L |
| Surface Finish | Ra 0.76 / 0.38 µm; electropolished options |
| Transmitter | Head transmitter 4–20 mA, HART, PROFIBUS PA, FOUNDATION Fieldbus; Bluetooth parametrization |
| Hygiene | 3-A; EHEDG; ASME BPE; FDA; TSE |
| Special Features | iTHERM QuickNeck tool-free insert removal; modular hygienic metric design for food & life sciences |