Macnaught

Macnaught MX Series Solvent Oval Gear Flow Meter

SKU · 40701 · MX Series Solvent · Brand: Macnaught
Available
Quote on request
No online payment · add lines to RFQ BOM

MX Solvent: oval-gear; ±0.5% (±0.25% avail); FEP seals; to 120 °C. RFQ.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Accuracy
±0.5% of reading (±0.25% available); repeatability ±0.03%
Type
Positive-displacement oval-gear flow meter (MX Series; solvent-capable constructions)
Sizes Flow
¼–4 in; approx. 0.5 LPH to 2500 LPM model-dependent
Materials
Billet aluminium / 316SS / PPS options; FEP-encapsulated seals on solvent S-series
Temperature
Up to 120 °C (248 °F) with SS/PEEK rotors (remote display)
Pressure
Up to ~1000–2000 PSI class by size (see cut sheet)
Download datasheet PDF

Fits solvent-capable oval-gear metering where you need a Macnaught MX Series solvent construction—±0.5% of reading (±0.25% available), ±0.03% repeatability, billet aluminium / 316SS / PPS options with FEP-encapsulated seals, and temperatures up to 120 °C with SS/PEEK rotors (remote display).

Key advantages

  • Accuracy — ±0.5% rdg (±0.25% available); ±0.03% repeatability
  • Sizes — ¼–4 in; ~0.5 LPH–2500 LPM model-dependent
  • Materials — Al / 316SS / PPS; FEP-encapsulated seals (solvent S-series)
  • Temperature — Up to 120 °C (248 °F) with SS/PEEK rotors (remote display)
  • Technology — Oval gear PD for solvents

Typical applications

  • Solvent transfer metering.
  • Chemical batching (compatible fluids).
  • Industrial PD solvent skids.

Selection guide

  • Body / seal materials
  • Size / flow
  • Remote vs local display

Common mistakes

  • Seal incompatibility.
  • Exceeding 120 °C.
  • Abrasives in solvent streams.

When to RFQ / what to tell us

  1. Fluid, size, materials.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU40701
BrandMacnaught
ModelMX Series Solvent
Product typeFlow Meter
TypePositive-displacement oval-gear flow meter (MX Series; solvent-capable constructions)
Accuracy±0.5% of reading (±0.25% available); repeatability ±0.03%
Sizes flow¼–4 in; approx. 0.5 LPH to 2500 LPM model-dependent
MaterialsBillet aluminium / 316SS / PPS options; FEP-encapsulated seals on solvent S-series
TemperatureUp to 120 °C (248 °F) with SS/PEEK rotors (remote display)

Documents

FAQ

Q: Solvent seals? A: FEP-encapsulated seals on solvent S-series.

Q: Max temp class? A: Up to 120 °C with SS/PEEK rotors (remote display).

Q: What should I send for a quote? A: Fluid/size/materials, quantity, ship-to.

Links

ParameterValue
Accuracy±0.5% of reading (±0.25% available); repeatability ±0.03%
TypePositive-displacement oval-gear flow meter (MX Series; solvent-capable constructions)
Sizes Flow¼–4 in; approx. 0.5 LPH to 2500 LPM model-dependent
MaterialsBillet aluminium / 316SS / PPS options; FEP-encapsulated seals on solvent S-series
TemperatureUp to 120 °C (248 °F) with SS/PEEK rotors (remote display)
PressureUp to ~1000–2000 PSI class by size (see cut sheet)
OutputsProgrammable digital display, pulse, intrinsically safe pulse, 4–20 mA options
InstallationNo flow conditioning required; compact lay length
DocumentMacnaught MX/M Series cut sheet + MX Series Selection Guide