Blancett

Blancett 900 Series Positive Displacement Flow Meter

SKU · 47264 · 900 Series Positive Displacement Flow Meter · Brand: Blancett
Available
Quote on request
No online payment · add lines to RFQ BOM

Blancett 900: rotary vane PD; 5000 psi; 30–200 °F; 1–2 in NPT; 2% acc; ±0.1% rep. RFQ.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Accuracy
2%
Type
Blancett 900 Series positive displacement water-flood flow meter (rotary vane)
Operating Temperature
30 to 200 F (-1 to 93 C)
Pressure Rating
5000 psi maximum
End Connections
1 in. NPT female and 2 in. NPT male
Repeatability
+/-0.1%
Download datasheet PDF

Fits high-pressure water-flood metering where you need a Blancett 900 Series meter. Rotary-vane positive displacement flow meter rated to 5000 psi with operating temperature 30 to 200 °F, 1 in NPT female and 2 in NPT male end connections, 2% accuracy and ±0.1% repeatability.

Key advantages

  • Type — Rotary vane PD (water-flood)
  • Pressure — 5000 psi maximum
  • Temperature — 30 to 200 °F (−1 to 93 °C)
  • Connections — 1 in NPT F / 2 in NPT M
  • Repeatability — ±0.1%

Typical applications

  • Water-flood injection.
  • High-pressure water metering.
  • Oilfield PD flow.

Selection guide

  • End connection
  • Output/register
  • Fluid cleanliness

Common mistakes

  • Abrasives in fluid.
  • Exceeding 5000 psi.
  • Temperature outside band.

When to RFQ / what to tell us

  1. Connection/options.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU47264
BrandBlancett
Model900 Series Positive Displacement Flow Meter
Product typePositive Displacement Flow Meter
TypeBlancett 900 Series positive displacement water-flood flow meter (rotary vane)
Operating temperature30 to 200 F (-1 to 93 C)
Pressure rating5000 psi maximum
End connections1 in. NPT female and 2 in. NPT male
Accuracy2%
Repeatability+/-0.1%

Documents

FAQ

Q: Max pressure? A: 5000 psi.

Q: Accuracy? A: 2%.

Q: What should I send for a quote? A: Connection/options, quantity, ship-to.

Links

ParameterValue
Accuracy2%
TypeBlancett 900 Series positive displacement water-flood flow meter (rotary vane)
Operating Temperature30 to 200 F (-1 to 93 C)
Pressure Rating5000 psi maximum
End Connections1 in. NPT female and 2 in. NPT male
Repeatability+/-0.1%
TurndownLow about 2.5:1; medium about 9:1; high about 2:1 (insert-dependent)
Flow Ranges ExamplesLow 68-172 bpd; mid 172-1543 bpd; high 1543-3086 bpd; mid gallon option 5-45 gpm
Body MaterialsStainless steel body; high-tech polymer bearings/rotor support for chemical/abrasion resistance
DimensionsEnd-to-end about 8.80 in (223.5 mm); height 8.00 in (203.2 mm); diameter 6.10 in (154.9 mm)
DocumentBlancett 900 Series Product Data Sheet PDM-DS-00134-EN-04 (Badger Meter widen OEM)