Image unavailable
Image unavailable
AEMC
AEMC 8220 Power Quality Analyzer & Meter
Quote on request
No online payment · add lines to RFQ BOM
8220: single-phase PQ; 6–600 V TRMS; ±(0.5%+2 cts). RFQ kit.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Supply
Six 1.5 V AA alkaline (≥8 h display on)
Voltage Trms
Phase-to-phase 660 V; phase-to-neutral 600 V
Current Trms
Probe dependent: MN to 240 A; MR to 1000 Aac/1400 Adc; AmpFlex to 6500 A
Frequency
40 to 70 Hz
Harmonics
1st to 50th; THD-F and THD-R for V and I
Power Energy
kW, kvar, kVA, PF, DPF; energy kWh/kvarh/VAh; inrush capture
Fits single-phase power-quality checks where you need an AEMC 8220—TRMS voltage 6–600 V with ±(0.5% + 2 counts) class accuracy for troubleshooting and metering.
Key advantages
- Role — Single-phase power quality analyzer & meter
- Voltage — 6–600 V TRMS
- Accuracy — ±(0.5% + 2 counts) on 6–600 V class
- Use — PQ troubleshooting and electrical metering
- Docs — OEM user manual available
Typical applications
- Single-phase PQ surveys.
- Facility voltage quality checks.
- Maintenance electrical metering.
Selection guide
- Current probe pairing
- Logging needs
- Kit accessories
Common mistakes
- Expecting three-phase simultaneous without the right model family.
- Wrong probe ratio setup.
- Ignoring CAT rating for the point of connection.
When to RFQ / what to tell us
- Kit contents, probes.
- Quantity, ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 34624 |
| Brand | AEMC |
| Model | 8220 Power Quality Analyzer & Meter |
| Product type | Power Quality Analyzer |
| Type | Single-phase power quality analyzer & meter (AEMC 8220) |
| Voltage | 6–600 V TRMS; ±(0.5% + 2 counts) class on 6–600 V |
| Role | Power quality analyzer / meter for single-phase circuits |
Documents
FAQ
Q: Voltage range? A: 6–600 V TRMS class.
Q: Phases? A: Single-phase analyzer/meter.
Q: What should I send for a quote? A: Kit/probes, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Supply | Six 1.5 V AA alkaline (≥8 h display on) |
| Voltage Trms | Phase-to-phase 660 V; phase-to-neutral 600 V |
| Current Trms | Probe dependent: MN to 240 A; MR to 1000 Aac/1400 Adc; AmpFlex to 6500 A |
| Frequency | 40 to 70 Hz |
| Harmonics | 1st to 50th; THD-F and THD-R for V and I |
| Power Energy | kW, kvar, kVA, PF, DPF; energy kWh/kvarh/VAh; inrush capture |
| Sampling | 256 samples/cycle; stores up to 99 snapshot sets |
| Communications | Optically isolated USB; DataView software |
| Safety Rating | EN 61010, 600 V CAT III, IP54 |
| Form Factor | 8.3 × 4.3 × 2.4 in (211 × 108 × 60 mm); 1.9 lb (0.88 kg) |
| Family | AEMC Model 8220 (discontinued; superseded by PEL series per OEM) |