Key parameters
Fits portable three-phase energy studies and basic power quality logging where you need V/A/Hz, power, PF, energy, demand, harmonics to the 50th, and event capture with waveform snapshot — powered from the measured circuit.
Key advantages
- Three-phase + neutral logging — Four flexible current probes included; V/A/Hz/power/PF/energy/demand.
- Harmonics to 50th + events — Dips, swells, inrush with waveform snapshot and high-res RMS profile.
- 1000 V CAT III / 600 V CAT IV — Power from the measured circuit; Energy Analyze Plus included.
- 2 DC aux channels — External temperature/humidity/air-speed sensors; Wi-Fi / Fluke Connect / VNC setup.
Typical applications
- Portable energy studies and basic power quality logging on three-phase systems.
- Load studies needing included flexible probes and long memory (>1 year typical).
- Surveys that add DC aux environmental sensors alongside electrical logging.
Selection guide
- Measurements — V, A, Hz, power (W/VA/var), PF, energy, demand, harmonics to 50th, THD, events.
- Phases — Three-phase + neutral with included 4 flexible current probes.
- Safety — 1000 V CAT III / 600 V CAT IV.
- Logging — Automatic logging of 500+ PQ parameters; >20 sessions; >1 year memory typical.
- Events — Dips, swells, inrush with waveform snapshot and high-res RMS profile.
- Display — Colour touch screen for in-field analysis.
- Connectivity — USB; Wi-Fi; Fluke Connect mobile/desktop; VNC setup.
- Powering — Power instrument directly from the measured circuit.
- Software — Fluke Energy Analyze Plus included.
- DC aux — 2 DC channels for external sensors (temperature/humidity/air speed).
- Special features — Intelligent connection verification; guided graphical setup.
- Functions — Energy studies, load studies, basic power quality logging.
- Form — Portable three-phase power quality logger.
Common mistakes
- Ordering 1736 when the job requires 1738-only Fluke Connect co-logging of two extra FC parameters — confirm feature need first.
- Ignoring CAT III 1000 V / CAT IV 600 V limits at the measurement point.
- Leaving DC aux sensor plan blank when temperature/humidity/air speed correlation is part of the study.
- Assuming unlimited memory without planning session count (>20 sessions; >1 year memory typical).
- Skipping connection verification / guided setup when multi-phase wiring errors are common on first install.
When to RFQ / what to tell us
- Study type (energy, load, basic PQ) and system voltage/current ranges.
- Need for DC aux sensors and Fluke Connect / Wi-Fi workflow.
- Quantity, ship-to, and whether 1738 co-log features are required instead.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 48770 |
| Brand | Fluke |
| Model | 1736 |
| Product type | threephasepower_logger |
| Measurements | V, A, Hz, power (W/VA/var), PF, energy, demand, harmonics to 50th, THD, events |
| Phases | Three-phase + neutral with included 4 flexible current probes |
| Safety | 1000 V CAT III / 600 V CAT IV |
| Logging | Automatic logging of 500+ PQ parameters; >20 sessions; >1 year memory typical |
| Events | Dips, swells, inrush with waveform snapshot and high-res RMS profile |
| Display | Colour touch screen for in-field analysis |
| Connectivity | USB; Wi-Fi; Fluke Connect mobile/desktop; VNC setup |
| Powering | Power instrument directly from the measured circuit |
| Software | Fluke Energy Analyze Plus included |
| DC aux | 2 DC channels for external sensors (temperature/humidity/air speed) |
| Approvals | CAT III 1000 V; CAT IV 600 V |
| Special features | Intelligent connection verification; guided graphical setup |
| Functions | Energy studies, load studies, basic power quality logging |
Documents
FAQ
Q: Can it power itself from the circuit? A: Yes — powering from the measured circuit is listed.
Q: Does it include flexible probes? A: Yes — four flexible current probes for three-phase + neutral are listed.
Q: What should I send for a quote? A: Study type, ranges, DC aux/FC needs, quantity. Compatible with systems using Fluke 1736 — we do not claim authorized-dealer status.
Links
| Parameter | Value |
|---|---|
| Display | Colour touch screen for in-field analysis |
| Approvals | CAT III 1000 V; CAT IV 600 V |
| Measurements | V, A, Hz, power (W/VA/var), PF, energy, demand, harmonics to 50th, THD, events |
| Phases | Three-phase + neutral with included 4 flexible current probes |
| Safety | 1000 V CAT III / 600 V CAT IV |
| Logging | Automatic logging of 500+ PQ parameters; >20 sessions; >1 year memory typical |
| Events | Dips, swells, inrush with waveform snapshot and high-res RMS profile |
| Connectivity | USB; Wi-Fi; Fluke Connect mobile/desktop; VNC setup |
| Powering | Power instrument directly from the measured circuit |
| Software | Fluke Energy Analyze Plus included |
| Dc Aux | 2 DC channels for external sensors (temperature/humidity/air speed) |
| Special Features | Intelligent connection verification; guided graphical setup |
| Functions | Energy studies, load studies, basic power quality logging |
| Form Factor | Portable three-phase power quality logger |