Image unavailable
Image unavailable
WIKA
WIKA CTR2000 Precision Thermometer
Quote on request
No online payment · add lines to RFQ BOM
8-channel PRT/SPRT readout; 0.01 °C; 0.001 °C resolution. RFQ + selection help.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Measuring range
ITS-90 −200 to +962 °C (−328 to +1764 °F); EN 60751 −200 to +850 °C; resistance 0–400 Ω
Accuracy
0.01 °C (instrument accuracy per CT 60.10)
Display
Large graphic VFD 128 × 18 pixels; units °C / °F / K / Ω
Display Resolution
0.001 °C
Channels
8 measuring inputs
Sensor Types
Industrial PRTs and SPRTs (Ro 25 Ω / 100 Ω); 3-wire and 4-wire
Fits precision temperature readout where you need a WIKA CTR2000 with eight PRT/SPRT inputs, 0.01 °C instrument accuracy, and 0.001 °C resolution.
Key advantages
- Range — ITS-90 −200 to +962 °C; EN 60751 −200 to +850 °C; resistance 0–400 Ω
- Accuracy / resolution — 0.01 °C instrument accuracy; 0.001 °C display resolution
- Channels — 8 measuring inputs; 3-wire and 4-wire PRTs/SPRTs
- Current — DC 1 mA alternating polarity
- Interface — RS-232; graphic VFD; °C/°F/K/Ω
Typical applications
- Lab PRT/SPRT readout and comparison.
- Multi-channel calibration benches.
- ITS-90 / CvD characterized sensors.
Selection guide
- Sensors — Industrial PRT vs SPRT; Ro 25/100 Ω
- Wiring — 3-wire (4 s) vs 4-wire (2 s) sample rate
- Characterizations — ITS-90 / CvD vs EN 60751
- Warm-up — Minimum 120 minutes per literature
Common mistakes
- Expecting full accuracy before the 120-minute warm-up.
- Mixing uncharacterized probes without EN 60751 assumptions.
- Ignoring channel count needs beyond eight.
When to RFQ / what to tell us
- Probe types/channels; characterization.
- RS-232 use; power cord region.
- Quantity and ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 20185 |
| Brand | WIKA |
| Model | WIKA CTR2000 Precision Thermometer |
| Product type | Precision Thermometer |
| Measuring range | ITS-90 −200 to +962 °C (−328 to +1764 °F); EN 60751 −200 to +850 °C; resistance 0–400 Ω |
| Accuracy | 0.01 °C (instrument accuracy per CT 60.10) |
| Display resolution | 0.001 °C |
| Channels | 8 measuring inputs |
| Sensor types | Industrial PRTs and SPRTs (Ro 25 Ω / 100 Ω); 3-wire and 4-wire |
| Sensor current | DC 1 mA alternating polarity |
| Data formats | ITS-90 and CvD for calibrated RT; EN 60751 for uncalibrated RT |
| Sample rate | 3-wire: 4 s; 4-wire: 2 s |
| Interface | RS-232 |
| Display | Large graphic VFD 128 × 18 pixels; units °C / °F / K / Ω |
| Dimensions / weight | 168 × 108 × 215 mm; 1 kg |
| Power | Max 30 VA; regional power cords |
| Warm-up | Minimum 120 minutes |
Documents
- WIKA CTR2000 documentation — request current OEM PDF on RFQ — request current OEM PDF on RFQ
FAQ
Q: How many channels? A: Eight measuring inputs.
Q: What resolution? A: 0.001 °C display resolution; 0.01 °C instrument accuracy.
Q: What should I send for a quote? A: Probes/channels, region power, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Measuring range | ITS-90 −200 to +962 °C (−328 to +1764 °F); EN 60751 −200 to +850 °C; resistance 0–400 Ω |
| Accuracy | 0.01 °C (instrument accuracy per CT 60.10) |
| Display | Large graphic VFD 128 × 18 pixels; units °C / °F / K / Ω |
| Display Resolution | 0.001 °C |
| Channels | 8 measuring inputs |
| Sensor Types | Industrial PRTs and SPRTs (Ro 25 Ω / 100 Ω); 3-wire and 4-wire |
| Sensor Current | DC 1 mA alternating polarity |
| Input Impedance | > 10 MΩ |
| Data Formats | ITS-90 and CvD for calibrated RT; EN 60751 for uncalibrated RT |
| Sample Rate | 3-wire: 4 s; 4-wire: 2 s |
| Interface | RS-232 |
| Dimensions Weight | 168 × 108 × 215 mm; 1 kg |
| Power | Max 30 VA; regional power cords |
| Warmup | Minimum 120 minutes |
| Smart Features | SMART probe log / calibration-status monitoring; password-protected instrument recalibration |