Fluke

Fluke 721 Dual Range Pressure Calibrator

SKU · 12354 · 721 · Brand: Fluke
Available
Quote on request
No online payment · add lines to RFQ BOM

Dual-sensor pressure calibrator. 0.025% FS; mA/V; optional RTD. RFQ + selection help.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Sensor Configuration
Dual isolated stainless-steel sensors: low 16 or 36 psig + high 100…5000 psi options
Pressure Accuracy
0.025 % of full scale (typical high/low sensors; 0.035 % FS on 5000 psi)
Application
Gas custody transfer / gas flow calibration (static + differential simultaneously)
Ma Measure
0 to 24 mA; ±0.015% of rdg ±0.002 mA
Vdc Measure
0 to 30 VDC; ±0.015% of rdg ±0.002 V (721 models)
Loop Power
Internal 24 V loop supply (721 models)
Download datasheet PDF

Fits gas custody-transfer calibration where you need a Fluke 721 with two isolated stainless-steel sensors, 0.025% FS class accuracy, and mA/voltage measurement.

Key advantages

  • Dual isolated sensors — Two isolated stainless steel pressure sensors for static/differential custody-transfer work
  • Accuracy — 0.025% of full scale class (high-range 5000 psi class listed 0.035% FS on some codes)
  • Low + high spans — Low sensor 16 or 36 psig class paired with high ranges to 100…5000 psi by model
  • Electrical — Measures 4–20 mA and voltage; 24 V loop supply on 721 (not Ex) models
  • Options — Pt100 RTD input; extend with 750P modules; 721Ex variants

Typical applications

  • Gas custody-transfer static and differential pressure checks.
  • Transmitter calibration with dual onboard sensors.
  • Sites needing 721Ex intrinsically safe variants.

Selection guide

  • Sensor pair — 16 or 36 psig low + high range code (100…5000 psi class)
  • 721 vs 721Ex — standard vs IS variant
  • RTD / modules — Pt100 option; 750P external modules

Common mistakes

  • Ordering 721Ex when you need 24 V loop supply — loop power is on non-Ex 721 models.
  • Ignoring the high-sensor accuracy note on 5000 psi codes (0.035% FS class).
  • Assuming a hand pump is built in — 721 is dual-sensor indicator/calibrator class, not a 718-style internal pump.

When to RFQ / what to tell us

  1. Low/high sensor pair and 721 vs 721Ex.
  2. RTD / 750P needs; quantity; ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU12354
BrandFluke
Model721 Dual Range Pressure Calibrator
Product typePressure Calibrator
Accuracy0.025% FS class (two isolated stainless steel sensors); some 5000 psi high sensors 0.035% FS
mA / electricalMeasures 4–20 mA and voltage; 24 V loop supply on non-Ex 721 models
FeaturesDual isolated sensors for gas custody-transfer calibration; Pt100 RTD input option; Extends range with 750P modules; 721Ex variants
Sensor pairsLow sensor 16 or 36 psig class with high ranges 100…5000 psi by model code

Documents

FAQ

Q: Why dual sensors? A: Simultaneous static and differential pressure for custody-transfer style checks.

Q: Accuracy? A: 0.025% FS class on listed sensors; some 5000 psi high sensors 0.035% FS.

Q: What should I send for a quote? A: Sensor pair, Ex yes/no, RTD/modules, quantity, ship-to.

Links

ParameterValue
Sensor ConfigurationDual isolated stainless-steel sensors: low 16 or 36 psig + high 100…5000 psi options
Pressure Accuracy0.025 % of full scale (typical high/low sensors; 0.035 % FS on 5000 psi)
ApplicationGas custody transfer / gas flow calibration (static + differential simultaneously)
Ma Measure0 to 24 mA; ±0.015% of rdg ±0.002 mA
Vdc Measure0 to 30 VDC; ±0.015% of rdg ±0.002 V (721 models)
Loop PowerInternal 24 V loop supply (721 models)
Temperature InputPt100 RTD input −40 to 150 °C (optional 720RTD probe)
Engineering Units19 pressure units selectable
External Modules750P Series modules 0–1 inH2O to 10,000 psi (721 models)
Operating Temperature−10 °C to +50 °C (721); −10 °C to +45 °C (721Ex)
Protection RatingIP-40
Size Weight7.9 × 4.3 × 2.3 in (20 × 11 × 5.8 cm); ~1 lb 3 oz
Power4× AA; >35 hours typical
FamilyFluke 721 / 721Ex Precision Pressure Calibrators