Fluke Calibration 3130 Pressure Calibrator
Portable pressure calibrator: −80 kPa…2 MPa internal pump, ±0.025% rdg + 0.01% FS. RFQ + selection help.
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Fits portable pressure transmitter and gauge calibration where you need an integrated motorized pump (−80 kPa to 2 MPa / −12 to 300 psi), mA/V measure, and 24 V loop supply in one ruggedized case.
Key advantages
- Internal motorized pump — −80 kPa to 2 MPa (−12 to 300 psi); external air 0 to 2 MPa.
- ±(0.025% rdg + 0.01% FS) — Pressure accuracy class for field calibration.
- mA / V + 24 V loop — Measure/generate 4–20 mA; 0–30 V dc measure; 24 V loop supply.
- Module-ready — Compatible with Fluke 700P and 750P pressure modules.
- NIST-traceable standard — Certificate standard; ISO 17025 accredited option (/C).
Typical applications
- Portable calibration of pressure transmitters and gauges to 300 psi / 2 MPa.
- Field loop checks needing mA/V measure and 24 V loop supply with pressure.
- Shops using Fluke 700P / 750P modules for extended ranges.
Selection guide
- Pressure range — Internal pump −80 kPa to 2 MPa (−12 to 300 psi); external air 0 to 2 MPa.
- Electrical — mA 0–24.000 mA; volts 0–30.000 V dc; generate/measure 4–20 mA; 24 V dc loop supply.
- Accuracy — Pressure ±(0.025% reading + 0.01% FS); mA ±(0.015% reading + 0.002 mA); volts ±(0.015% reading + 0.002 V).
- Process connection — 1/8 in NPT (external supply port and test port).
- Operating temperature — −10 to +50 °C; no accuracy effect 15–35 °C; add ±0.002% FS/°C outside.
- Supply / battery — 12 V dc via universal adapter/charger; internal 3800 mAh NiMH; ~50 hours measure-only/external air; ~100 calibration cycles to 300 psi with internal pump.
- Modules — Compatible with Fluke 700P and 750P pressure modules.
- EMI / cal — EN61326:2006 Annex A; NIST-traceable certificate standard; ISO 17025 accredited calibration option (/C).
Common mistakes
- Assuming the internal pump covers above 2 MPa / 300 psi — external air path is also 0…2 MPa; use modules or a different calibrator for higher spans.
- Ignoring the 15–35 °C no-accuracy-effect window — outside that, add ±0.002% FS/°C.
- Ordering without the /C ISO 17025 option when the QA system requires accredited data on receipt.
- Leaving module needs blank when the job spans beyond the internal 2 MPa pump.
When to RFQ / what to tell us
- Max pressure span vs 2 MPa / 300 psi internal pump, and any 700P/750P module needs.
- mA/V / 24 V loop use; ISO 17025 (/C) yes/no.
- Quantity, ship-to, fittings/lead kit needs.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 39401 |
| Brand | Fluke Calibration |
| Model | 3130 |
| Product type | portablepressurecalibrator |
| Measuring range | Pressure internal pump −80 kPa to 2 MPa (−12 to 300 psi); external air 0 to 2 MPa; mA 0–24.000 mA; volts 0–30.000 V dc |
| Accuracy | Pressure ±(0.025% reading + 0.01% FS); mA ±(0.015% reading + 0.002 mA); volts ±(0.015% reading + 0.002 V) |
| Output / functions | Generate/measure 4–20 mA; 24 V dc loop supply; pressure via internal motorized pump or external gas |
| Process connection | 1/8 in NPT (external supply port and test port) |
| Operating temperature | −10 to +50 °C; no accuracy effect 15–35 °C; add ±0.002% FS/°C outside |
| Supply | 12 V dc via universal adapter/charger; internal 3800 mAh NiMH pack |
| Battery life | Approx. 50 hours measure-only/external air; ~100 calibration cycles to 300 psi with internal pump |
| Physical | 15.25 × 12 × 7 in; ~7 kg (15 lb); ruggedized case with storage for leads/fittings |
| Engineering units | psi, bar, mbar, kPa, MPa, kgf/cm², mm/cm/in H2O, mm/in Hg |
| Module compatibility | Compatible with Fluke 700P and 750P pressure modules |
| EMI | EN61326:2006 Annex A |
| Approvals / cal | NIST-traceable certificate standard; ISO 17025 accredited calibration option (/C) |
| Notes | Specs from Fluke Calibration 3130 Technical Data and User Manual. |
Documents
FAQ
Q: What pressure span does the internal pump cover? A: −80 kPa to 2 MPa (−12 to 300 psi). External air path is 0 to 2 MPa .
Q: Can it power a 4–20 mA transmitter? A: Yes — generate/measure 4–20 mA with a 24 V dc loop supply is listed.
Q: What should I send for a quote? A: Spans, media, modules, certificate class (/C yes/no), quantity. Compatible with systems using Fluke Calibration 3130 — we do not claim authorized-dealer status.
Links
| Parameter | Value |
|---|---|
| Measuring range | Pressure internal pump −80 kPa to 2 MPa (−12 to 300 psi); external air 0 to 2 MPa; mA 0–24.000 mA; volts 0–30.000 V dc |
| Accuracy | Pressure ±(0.025% reading + 0.01% FS); mA ±(0.015% reading + 0.002 mA); volts ±(0.015% reading + 0.002 V) |
| Output | Generate/measure 4–20 mA; 24 V dc loop supply; pressure generation via internal motorized pump or external gas |
| Supply | 12 V dc via universal adapter/charger; internal 3800 mAh NiMH pack |
| Process connection | 1/8 in NPT (external supply port and test port) |
| Approvals | NIST-traceable certificate standard; ISO 17025 accredited calibration option (/C) |
| Notes | Specs from Fluke Calibration 3130 Portable Pressure Calibrator Technical Data and User Manual. |
| Operating Temperature | −10 to +50 °C; no accuracy effect 15–35 °C; add ±0.002% FS/°C outside |
| Battery Life | Approx. 50 hours measure-only/external air; ~100 calibration cycles to 300 psi with internal pump |
| Physical | 15.25 × 12 × 7 in; ~7 kg (15 lb); ruggedized case with storage for leads/fittings |
| Engineering Units | psi, bar, mbar, kPa, MPa, kgf/cm², mm/cm/in H2O, mm/in Hg |
| Module Compatibility | Compatible with Fluke 700P and 750P pressure modules |
| Emi | EN61326:2006 Annex A |