Dwyer Instruments

Dwyer Series 475 Mark III Digital Manometer

SKU · 41034 · Series 475 Mark III Digital Manometer · Brand: Dwyer Instruments
Available
Quote on request
No online payment · add lines to RFQ BOM

Dwyer 475 Mark III: IS digital manometer; 1 in w.c.–150 psid; ±0.5% FS. RFQ.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Accuracy
±0.5% FS at 60–78 °F; ±1.5% FS outside
Display
4-digit LCD 0.42 in
Approvals
CE; FM Class I Div 2 Groups A–D T4
Type
Intrinsically safe handheld digital manometer (Series 475)
Ranges
1 in w.c. to 150 psid model chart
Hysteresis
±0.1% FS
Download datasheet PDF

Fits intrinsically safe handheld differential pressure checks where you need a Dwyer Series 475 Mark III. Digital manometer with model ranges from 1 in w.c. to 150 psid, accuracy ±0.5% FS at 60–78 °F (±1.5% FS outside), hysteresis ±0.1% FS, 4-digit LCD, 9 V alkaline battery, service on air and compatible combustible gases, operating 0 to 140 °F.

Key advantages

  • Type — IS handheld digital manometer
  • Ranges — 1 in w.c. to 150 psid
  • Accuracy — ±0.5% FS (60–78 °F)
  • Hysteresis — ±0.1% FS
  • Service — Air / compatible combustible gases

Typical applications

  • Field DP checks.
  • HVAC / process manometry.
  • IS area pressure surveys.

Selection guide

  • Range model
  • Gas compatibility
  • IS approvals needed

Common mistakes

  • Wrong range model.
  • Incompatible gas media.
  • Accuracy outside 60–78 °F window.

When to RFQ / what to tell us

  1. Range model.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU41034
BrandDwyer Instruments
ModelSeries 475 Mark III Digital Manometer
Product typeDigital Manometer
TypeIntrinsically safe handheld digital manometer (Series 475)
Ranges1 in w.c. to 150 psid model chart
Accuracy±0.5% FS at 60–78 °F; ±1.5% FS outside
Hysteresis±0.1% FS
Display4-digit LCD 0.42 in
Power9 V alkaline battery
ServiceAir and compatible combustible gases
Temp limits0 to 140 °F operating

Documents

FAQ

Q: Accuracy? A: ±0.5% FS at 60–78 °F.

Q: Ranges? A: 1 in w.c. to 150 psid by model.

Q: What should I send for a quote? A: Range model, quantity, ship-to.

Links

ParameterValue
Accuracy±0.5% FS at 60–78 °F; ±1.5% FS outside
Display4-digit LCD 0.42 in
ApprovalsCE; FM Class I Div 2 Groups A–D T4
TypeIntrinsically safe handheld digital manometer (Series 475)
Ranges1 in w.c. to 150 psid model chart
Hysteresis±0.1% FS
Power9 V alkaline battery
ServiceAir and compatible combustible gases
Temp Limits0 to 140 °F operating
Weight10.8 oz (306 g)