Endress+Hauser

Endress+Hauser Deltabar PMD75 Differential Pressure Transmitter

SKU · 67890 · Deltabar PMD75 · Brand: Endress+Hauser
Available
Quote on request
No online payment · add lines to RFQ BOM

E+H Deltabar PMD75: DP; to ±0.035% platinum; TD 100:1; HART/PA/FF. RFQ.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Accuracy
Reference accuracy up to ±0.035% (platinum); standard to TD 100:1
Type
Differential pressure transmitter with metallic measuring cell (Deltabar S PMD75)
Turn Down
Up to 100:1 (higher on request)
Outputs
4–20 mA HART; PROFIBUS PA; FOUNDATION Fieldbus
Applications
Flow (with primary devices), level/volume/mass in liquids, DP filter/pump monitoring
Process Temperature
High process temperatures up to 400 °C (752 °F) with diaphragm seal
Download datasheet PDF

Fits differential pressure measurement where you need an Endress+Hauser Deltabar PMD75. Metallic-cell DP transmitter with reference accuracy up to ±0.035% (platinum), turndown to 100:1, outputs 4–20 mA HART / PROFIBUS PA / FOUNDATION Fieldbus, for flow with primaries, level/volume/mass and filter/pump DP monitoring.

Key advantages

  • Accuracy — Up to ±0.035% (platinum)
  • Turndown — Up to 100:1
  • Outputs — HART / PA / FF
  • Cell — Metallic measuring cell
  • Uses — Flow / level / DP monitoring

Typical applications

  • Orifice / venturi DP flow.
  • Closed vessel level.
  • Filter DP.

Selection guide

  • Span / URL
  • Protocol
  • Process connections

Common mistakes

  • Wrong flange rating.
  • Turndown beyond claim.
  • Impulse line errors.

When to RFQ / what to tell us

  1. Range/protocol/connections.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU67890
BrandEndress+Hauser
ModelDeltabar PMD75
Product typeDifferential Pressure Transmitter
TypeDifferential pressure transmitter with metallic measuring cell (Deltabar S PMD75)
AccuracyReference accuracy up to ±0.035% (platinum); standard to TD 100:1
Turn downUp to 100:1 (higher on request)
Outputs4–20 mA HART; PROFIBUS PA; FOUNDATION Fieldbus
ApplicationsFlow (with primary devices), level/volume/mass in liquids, DP filter/pump monitoring

Documents

FAQ

Q: Accuracy? A: Up to ±0.035% platinum.

Q: Protocols? A: HART, PA, FF.

Q: What should I send for a quote? A: Range/protocol/connections, quantity, ship-to.

Links

ParameterValue
AccuracyReference accuracy up to ±0.035% (platinum); standard to TD 100:1
TypeDifferential pressure transmitter with metallic measuring cell (Deltabar S PMD75)
Turn DownUp to 100:1 (higher on request)
Outputs4–20 mA HART; PROFIBUS PA; FOUNDATION Fieldbus
ApplicationsFlow (with primary devices), level/volume/mass in liquids, DP filter/pump monitoring
Process TemperatureHigh process temperatures up to 400 °C (752 °F) with diaphragm seal
SafetySIL2/SIL3 capable per IEC 61508 (TÜV SÜD) for flow and DP monitoring
FeaturesHistoROM/M-DAT electronics replacement; TempC diaphragm-seal membrane option
DocumentEndress+Hauser TI00382P Technical Information + BA00301P Operating Instructions