Ashcroft

Ashcroft B-Series Pressure Switch

SKU · 37159 · B Series Pressure Switch · Brand: Ashcroft
Available
Quote on request
No online payment · add lines to RFQ BOM

B-Series: vacuum to 3000 psi; ±1% span; mechanical contacts. RFQ range.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Measuring range
Pressure vacuum to 3000 psi; differential 0–600 psid; hydraulic 1000–7500 psi
Accuracy
Setpoint repeatability ±1% of full range (additional ±1%/50 °F shift from 70 °F set typical)
Output
SPDT or DPDT switch elements; wide element selection
Process connection
¼ NPT female standard; ½ NPT female or ¼ F × ½ M combo optional
Electrical connection
¾ NPT female standard; ½ NPT or M20×1.5 optional
Wetted parts
Diaphragm Buna-N, Viton, Teflon, 316 SS, or Monel
Download datasheet PDF

Fits general industrial pressure switching where you need an Ashcroft B-Series switch—vacuum to about 3,000 psi with mechanical contacts and ±1% of span setpoint repeatability.

Key advantages

  • Ranges — Vacuum to ~3,000 psi
  • Repeatability — ±1% of span
  • Output — Mechanical switch contacts
  • Use — Industrial alarm / control
  • Platform — Ashcroft B-Series family

Typical applications

  • Plant utility pressure trips.
  • Compressor control.
  • General OEM switching.

Selection guide

  • Range
  • Contact rating
  • Process connection

Common mistakes

  • Confusing with XP F-Series enclosure needs.
  • Wrong media compatibility.
  • Setpoint outside range.

When to RFQ / what to tell us

  1. Range, connection.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU37159
BrandAshcroft
ModelB Series Pressure Switch
Product typePressure Switch
TypeIndustrial pressure switch (Ashcroft B-Series)
RangeVacuum to about 3,000 psi
OutputMechanical switch contacts
Repeatability±1% of span

Documents

FAQ

Q: Repeatability? A: ±1% of span.

Q: Max pressure class? A: About 3,000 psi.

Q: What should I send for a quote? A: Range/connection, quantity, ship-to.

Links

ParameterValue
Measuring rangePressure vacuum to 3000 psi; differential 0–600 psid; hydraulic 1000–7500 psi
AccuracySetpoint repeatability ±1% of full range (additional ±1%/50 °F shift from 70 °F set typical)
OutputSPDT or DPDT switch elements; wide element selection
Process connection¼ NPT female standard; ½ NPT female or ¼ F × ½ M combo optional
Electrical connection¾ NPT female standard; ½ NPT or M20×1.5 optional
Wetted partsDiaphragm Buna-N, Viton, Teflon, 316 SS, or Monel
ProtectionB4/H4 NEMA 4X IP66; B7 NEMA 7/9 IP66
Ambient temperature−20 to 150 °F (−28 to 65 °C); calibrated at 70 °F
ApprovalsUL; CSA; FM; ATEX; IECEx; CE; UKCA; CRN; SIL 3 Capable; NSF-61; RoHS
SetpointSingle setpoint factory-set or field adjustable 15–100% of range
Enclosure MaterialEpoxy-coated aluminum standard; optional 316 SS (NEMA 7/9)
Process Temperature0–150 °F Buna/Teflon; 20–300 °F Viton; 0–300 °F SS/Monel
DeadbandFixed or limited adjustable per switch element
Special FeaturesNACE and fire-safe designs; SIL 3 capable B/D series; hermetically sealed element options