Endress+Hauser

Endress+Hauser Ceraphant PTP31B Pressure Switch

SKU · 45740 · Ceraphant PTP31B · Brand: Endress+Hauser
Available
Quote on request
No online payment · add lines to RFQ BOM

E+H Ceraphant PTP31B: pressure switch; to 400 bar; PNP/IO-Link; to 0.3% Platinum. RFQ.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Measuring range
Gauge/absolute: from 0 to +400 mbar (0 to +6 psi) to 0 to +400 bar (0 to +5,800 psi); OPL to –1…+600 bar
Accuracy
Reference accuracy standard up to 0.5%; Platinum up to 0.3%
Output
1× PNP switch (3-wire); 2× PNP + IO-Link (4-wire); or 1× PNP + 4–20 mA + IO-Link (4-wire)
Supply
10–30 VDC analog / IO-Link (IO-Link guaranteed ≥18 V)
Process connection
Thread ISO 228 (incl. flush), ASME, DIN 13, JIS
Wetted parts
Housing and process connections 316L; metallic diaphragm 316L
Download datasheet PDF

Fits compact pressure switching where you need an Endress+Hauser Ceraphant PTP31B—metallic-membrane pressure switch spanning gauge/absolute cells from about 400 mbar to 400 bar URL, reference accuracy to 0.5% (Platinum to 0.3%), and PNP / IO-Link / 4–20 mA output combinations.

Key advantages

  • Range — About 400 mbar to 400 bar URL class
  • Accuracy — To 0.5%; Platinum to 0.3%
  • Outputs — PNP; 2× PNP + IO-Link; PNP + 4–20 mA + IO-Link
  • Supply — 10–30 VDC
  • Membrane — 316L metallic process membrane

Typical applications

  • Machine pressure switch.
  • Hydraulic / pneumatic points.
  • IO-Link pressure discrete.

Selection guide

  • Gauge vs absolute
  • Output wiring
  • Process thread

Common mistakes

  • Exceeding process temp 100 °C.
  • Wrong OPL.
  • IO-Link below 18 V.

When to RFQ / what to tell us

  1. Range/output/thread.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU45740
BrandEndress+Hauser
ModelCeraphant PTP31B
Product typePressure Switch
Measuring rangeGauge/absolute: from 0 to +400 mbar (0 to +6 psi) to 0 to +400 bar (0 to +5,800 psi); OPL to –1…+600 bar
AccuracyReference accuracy standard up to 0.5%; Platinum up to 0.3%
Output signal1× PNP switch (3-wire); 2× PNP + IO-Link (4-wire); or 1× PNP + 4–20 mA + IO-Link (4-wire)
Supply voltage10–30 VDC analog / IO-Link (IO-Link guaranteed ≥18 V)
Process temperature–40 to +100 °C (–40 to +212 °F) at process connection
Ambient temperature–20 to +70 °C (–4 to +158 °F)
Sensor typeMetallic process membrane (316L); absolute and gauge pressure switch
Process connectionThread ISO 228 (incl. flush), ASME, DIN 13, JIS

Documents

FAQ

Q: Accuracy? A: To 0.5%; Platinum to 0.3%.

Q: Outputs? A: PNP / IO-Link / 4–20 mA combinations.

Q: What should I send for a quote? A: Range/output/thread, quantity, ship-to.

Links

ParameterValue
Measuring rangeGauge/absolute: from 0 to +400 mbar (0 to +6 psi) to 0 to +400 bar (0 to +5,800 psi); OPL to –1…+600 bar
AccuracyReference accuracy standard up to 0.5%; Platinum up to 0.3%
Output1× PNP switch (3-wire); 2× PNP + IO-Link (4-wire); or 1× PNP + 4–20 mA + IO-Link (4-wire)
Supply10–30 VDC analog / IO-Link (IO-Link guaranteed ≥18 V)
Process connectionThread ISO 228 (incl. flush), ASME, DIN 13, JIS
Wetted partsHousing and process connections 316L; metallic diaphragm 316L
Ambient temperature–20 to +70 °C (–4 to +158 °F)
Sensor typeMetallic process membrane (316L); absolute and gauge pressure switch
Process Temperature–40 to +100 °C (–40 to +212 °F) at process connection
Turn DownUp to 5:1