Yokogawa

Yokogawa CL300 Series Clamp-On Testers

SKU · 24475 · CL300 Series Clamp-On Testers · Brand: Yokogawa
Available
Quote on request
No online payment · add lines to RFQ BOM

CL320/340/345/360 leakage & AC clamps; 0.01 mA class; True RMS CL345. RFQ + selection help.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Measuring range
CL320: 20/200 mA, 200 A AC; CL340/CL345: 40/400 mA, 400 A AC; CL360: 200 mA / 2 / 20 / 200 / 1000 A AC
Series
Yokogawa 300 Series / CL Series clamp-on testers (CL320, CL340, CL345, CL360 featured for leakage)
Resolution
CL320/CL340/CL345: 0.01 mA (lowest range); CL360: 0.1 mA (lowest range)
Jaw Diameter
CL320 24 mm; CL340/CL345 40 mm; CL360 68 mm measurable conductor
Detection Method
CL320/CL340/CL360 mean value; CL345 True RMS
Frequency Response
CL320 40 Hz–400 Hz; CL340/CL345 20 Hz–1 kHz; CL360 40 Hz–1 kHz
Download datasheet PDF

Fits leakage and AC current clamp work where you need Yokogawa CL Series models (CL320/CL340/CL345/CL360) with milliamp-class resolution and jaw sizes from 24 mm to 68 mm.

Key advantages

  • Models — CL320 / CL340 / CL345 / CL360 leakage and AC clamp family
  • Ranges — CL320: 20/200 mA, 200 A; CL340/345: 40/400 mA, 400 A; CL360: to 1000 A AC
  • Resolution — Down to 0.01 mA (CL320/340/345); 0.1 mA (CL360 lowest)
  • Detection — Mean value (CL320/340/360); True RMS on CL345
  • Functions — Data hold; peak hold (340/345/360); filter (CL320+); recorder/waveform out (CL360)

Typical applications

  • Leakage current troubleshooting.
  • AC load current checks.
  • True RMS leakage with CL345.

Selection guide

  • Model — mA sensitivity vs 1000 A reach
  • True RMS — CL345 vs mean-value siblings
  • Jaw — 24 / 40 / 68 mm conductor
  • Outputs — CL360 recorder/waveform needs

Common mistakes

  • Using mean-value clamp on heavily distorted leakage.
  • Oversized conductor for jaw.
  • Wrong CAT rating assumption — check Bulletin CL-E by model.

When to RFQ / what to tell us

  1. CL320/340/345/360; accessories.
  2. Quantity and ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU24475
BrandYokogawa
ModelCL300 / CL Series Clamp-On Testers
Product typeClamp Meter
SeriesYokogawa 300 Series / CL Series clamp-on testers (CL320, CL340, CL345, CL360 featured for leakage)
Measuring rangeCL320: 20/200 mA, 200 A AC; CL340/CL345: 40/400 mA, 400 A AC; CL360: 200 mA / 2 / 20 / 200 / 1000 A AC
ResolutionCL320/CL340/CL345: 0.01 mA (lowest range); CL360: 0.1 mA (lowest range)
Jaw diameterCL320 24 mm; CL340/CL345 40 mm; CL360 68 mm measurable conductor
Detection methodCL320/CL340/CL360 mean value; CL345 True RMS
Frequency responseCL320 40 Hz–400 Hz; CL340/CL345 20 Hz–1 kHz; CL360 40 Hz–1 kHz
FunctionsData hold (all); peak hold (CL340/CL345/CL360); filter switch (CL320+); recorder & waveform monitor output (CL360)
SafetyPer Bulletin CL-E EN 61010 category ratings by model (series includes CAT III designs)
Product familyLeakage and AC/AC-DC clamp-on testers — CL Series + 30031A/30032A leakage models

Documents

FAQ

Q: Which for True RMS? A: CL345 is True RMS; others in this set are mean-value detection.

Q: Finest resolution? A: 0.01 mA on CL320/CL340/CL345 lowest ranges.

Q: What should I send for a quote? A: Model/accessories, quantity, ship-to.

Links

ParameterValue
Measuring rangeCL320: 20/200 mA, 200 A AC; CL340/CL345: 40/400 mA, 400 A AC; CL360: 200 mA / 2 / 20 / 200 / 1000 A AC
SeriesYokogawa 300 Series / CL Series clamp-on testers (CL320, CL340, CL345, CL360 featured for leakage)
ResolutionCL320/CL340/CL345: 0.01 mA (lowest range); CL360: 0.1 mA (lowest range)
Jaw DiameterCL320 24 mm; CL340/CL345 40 mm; CL360 68 mm measurable conductor
Detection MethodCL320/CL340/CL360 mean value; CL345 True RMS
Frequency ResponseCL320 40 Hz–400 Hz; CL340/CL345 20 Hz–1 kHz; CL360 40 Hz–1 kHz
FunctionsData hold (all); peak hold (CL340/CL345/CL360); filter switch (CL320+); recorder & waveform monitor output (CL360)
SafetyPer Bulletin CL-E EN 61010 category ratings by model (series includes CAT III designs)
Product FamilyLeakage and AC/AC-DC clamp-on testers — CL Series + 30031A/30032A leakage models
DocumentBulletin CL-E Clamp-on Testers 300 Series and CL Series