Druck

Druck UNIK 5000 Pressure Sensor

SKU · 32260 · UNIK 5000 · Brand: Druck
Available
Quote on request
No online payment · add lines to RFQ BOM

Configurable pressure sensing platform. 70 mbar…700 bar, ±0.04% FS Premium, mA/V/mV outputs. RFQ + engineer selection help.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Measuring range
70 mbar…700 bar (1…10000 psi); gauge / sealed gauge / absolute / wet-dry & wet-wet differential (by config)
Accuracy
Industrial ±0.2% FS BSL; Improved ±0.1% FS BSL; Premium ±0.04% FS BSL (grade by option)
Accuracy % FS
0.04
Output
mV passive/linearised; 4–20 mA; 0–5 V; 0–10 V; 0.5–4.5 V ratiometric; configurable voltage (by electronics option)
Supply
Depends on output: e.g. mA 7–28 VDC; mV/voltage options typically 2.5–16 VDC (see datasheet table)
Process connection
Multiple pressure connector options (incl. G1/4 depth cone, NPT/UNJF/VCR and others per datasheet)
Download datasheet PDF

Fits OEM and process builds that need a configurable stainless pressure transducer across 70 mbar…700 bar with selectable accuracy grade, output electronics, and connector options — not a single fixed SKU.

Key advantages

  • 70 mbar…700 bar platform — gauge, sealed gauge, absolute, and differential configs on one family.
  • Premium ±0.04% FS BSL — Industrial ±0.2% / Improved ±0.1% / Premium ±0.04% accuracy grades.
  • Output flexibility — mV, 4–20 mA, 0–5 V, 0–10 V, 0.5–4.5 V ratiometric, and configurable voltage.
  • Connector matrix — Multiple process and electrical connectors with IP depending on chosen interface.

Typical applications

  • OEM machine builds that configure one pressure platform across many spans.
  • Process skids needing Premium accuracy with 4–20 mA or voltage output.
  • Differential wet-dry / wet-wet points ordered from the UNIK 5000 option tree.

Selection guide

  • Measuring range / type — 70 mbar…700 bar (1…10000 psi); gauge / sealed gauge / absolute / wet-dry & wet-wet differential (by config). State pressure type and span first.
  • Accuracy grade — Industrial ±0.2% FS BSL; Improved ±0.1% FS BSL; Premium ±0.04% FS BSL (grade by option).
  • Output — mV passive/linearised; 4–20 mA; 0–5 V; 0–10 V; 0.5–4.5 V ratiometric; configurable voltage (by electronics option).
  • Supply — Depends on output: e.g. mA 7–28 VDC; mV/voltage options typically 2.5–16 VDC (see OEM documentation table).
  • Process connection — Multiple pressure connector options (incl. G1/4 depth cone, NPT/UNJF/VCR and others per OEM documentation).
  • Electrical connection — Multiple electrical connector options (IP rating depends on connector; demountable options available).
  • Wetted / housing — Stainless steel 316L; Hastelloy C276 option; fluids must be compatible with selected materials. Stainless steel construction.
  • IP — IP65 to IP68 depending on electrical connector / reference type (see OEM documentation notes).
  • Ambient — Operating −55…+125 °C (−67…+257 °F); compensated ranges selectable (e.g. −10…+50 °C).
  • Overpressure — High overpressure capability (values depend on range/connector; see OEM documentation).

Common mistakes

  • Quoting a single “UNIK 5000” without the full model code — range, pressure type, accuracy grade, output, and connectors are all options.
  • Mixing mA supply expectations (7–28 VDC) with mV/voltage excitation (typically 2.5–16 VDC).
  • Assuming IP68 on every build; IP is connector- and reference-type dependent (IP65 to IP68).
  • Specifying 316L when media need Hastelloy C276 — wetted material is a configuration choice.
  • Claiming Ex ia / ATEX/IECEx without the hazardous-area option on the order code.
  • Leaving media temperature blank — confirm against the selected compensated range and process duty on the quote.

When to RFQ / what to tell us

  1. Pressure type (gauge / sealed gauge / absolute / wet-dry or wet-wet DP) and required span + units.
  2. Accuracy grade (Industrial / Improved / Premium) and output electronics (mA / V / mV / ratiometric).
  3. Process and electrical connectors; IP need; media chemistry (316L vs Hastelloy C276).
  4. Operating / compensated temperature range and overpressure expectation.
  5. Hazardous-area marks required (ATEX/IECEx Ex ia etc.), quantity, ship-to country.

Request a Quote · Get selection help

Specs

SpecValue
SKU32260
BrandDruck
ModelUNIK 5000
Product typetransducer
Pressure typegauge / sealed gauge / absolute / wet-dry & wet-wet differential (by config)
Measuring range70 mbar…700 bar (1…10000 psi) by configuration
AccuracyIndustrial ±0.2% FS BSL; Improved ±0.1% FS BSL; Premium ±0.04% FS BSL (grade by option)
Output signalmV passive/linearised; 4–20 mA; 0–5 V; 0–10 V; 0.5–4.5 V ratiometric; configurable voltage (by electronics option)
Supply voltageDepends on output: e.g. mA 7–28 VDC; mV/voltage options typically 2.5–16 VDC (see OEM documentation table)
Process connectionMultiple pressure connector options (incl. G1/4 depth cone, NPT/UNJF/VCR and others per OEM documentation)
Electrical connectionMultiple electrical connector options (IP rating depends on connector; demountable options available)
Wetted materialsStainless steel 316L; Hastelloy C276 option; fluids must be compatible with selected materials
Housing materialStainless steel construction
IP ratingIP65 to IP68 depending on electrical connector / reference type (see OEM documentation notes)
Ambient temperatureOperating −55…+125 °C (−67…+257 °F); compensated ranges selectable (e.g. −10…+50 °C)
Overpressure limitHigh overpressure capability (values depend on range/connector; see OEM documentation)
Displaynone
ApprovalsATEX; IECEx; CE
Hazardous areaOptional hazardous-area certifications (e.g. ATEX/IECEx Ex ia); see OEM documentation approvals
NotesConfigurable OEM platform (Baker Hughes / Druck). Specs are capability envelope across options; order-specific model code required. Media temperature / burst are not single catalog limits — confirm on quote.

Documents

FAQ

Q: Is UNIK 5000 one fixed transmitter? A: No. It is a configurable sensing platform. Range, pressure type, accuracy grade, output, connectors, and approvals are selected by model code — send process data so we can lock a build.

Q: Which accuracy grade should I pick? A: Industrial ±0.2% FS BSL, Improved ±0.1% FS BSL, or Premium ±0.04% FS BSL. Match the grade to loop tolerance and cost — state the required %FS in the RFQ.

Q: Which approvals can I claim? A: CE plus optional ATEX/IECEx (e.g. Ex ia) when ordered. Only marks on the datasheet and ordered configuration apply.

Q: What should I send for a quote? A: Pressure type and span, accuracy grade, output and supply, connectors, media, temperature, IP / Ex needs, quantity. Compatible with systems using Druck UNIK 5000 if you need a drop-in check — we do not claim authorized-dealer status.

Links

ParameterValue
Measuring range70 mbar…700 bar (1…10000 psi); gauge / sealed gauge / absolute / wet-dry & wet-wet differential (by config)
AccuracyIndustrial ±0.2% FS BSL; Improved ±0.1% FS BSL; Premium ±0.04% FS BSL (grade by option)
Accuracy % FS0.04
OutputmV passive/linearised; 4–20 mA; 0–5 V; 0–10 V; 0.5–4.5 V ratiometric; configurable voltage (by electronics option)
SupplyDepends on output: e.g. mA 7–28 VDC; mV/voltage options typically 2.5–16 VDC (see datasheet table)
Process connectionMultiple pressure connector options (incl. G1/4 depth cone, NPT/UNJF/VCR and others per datasheet)
Electrical connectionMultiple electrical connector options (IP rating depends on connector; demountable options available)
Wetted partsStainless steel 316L; Hastelloy C276 option; fluids must be compatible with selected materials
HousingStainless steel construction
ProtectionIP65 to IP68 depending on electrical connector / reference type (see datasheet notes)
Ambient temperatureOperating −55…+125 °C (−67…+257 °F); compensated ranges selectable (e.g. −10…+50 °C)
Pressure typeother
Displaynone
ApprovalsATEX; IECEx; CE
Hazardous areaOptional hazardous-area certifications (e.g. ATEX/IECEx Ex ia); see datasheet approvals
NotesConfigurable OEM platform (Baker Hughes / Druck). Specs are capability envelope across options; order-specific model code required.
Overpressure LimitHigh overpressure capability (values depend on range/connector; see datasheet)