Druck UNIK 5000 Pressure Sensor
Configurable pressure sensing platform. 70 mbar…700 bar, ±0.04% FS Premium, mA/V/mV outputs. RFQ + engineer selection help.
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Fits OEM and process builds that need a configurable stainless pressure transducer across 70 mbar…700 bar with selectable accuracy grade, output electronics, and connector options — not a single fixed SKU.
Key advantages
- 70 mbar…700 bar platform — gauge, sealed gauge, absolute, and differential configs on one family.
- Premium ±0.04% FS BSL — Industrial ±0.2% / Improved ±0.1% / Premium ±0.04% accuracy grades.
- Output flexibility — mV, 4–20 mA, 0–5 V, 0–10 V, 0.5–4.5 V ratiometric, and configurable voltage.
- Connector matrix — Multiple process and electrical connectors with IP depending on chosen interface.
Typical applications
- OEM machine builds that configure one pressure platform across many spans.
- Process skids needing Premium accuracy with 4–20 mA or voltage output.
- Differential wet-dry / wet-wet points ordered from the UNIK 5000 option tree.
Selection guide
- Measuring range / type — 70 mbar…700 bar (1…10000 psi); gauge / sealed gauge / absolute / wet-dry & wet-wet differential (by config). State pressure type and span first.
- Accuracy grade — Industrial ±0.2% FS BSL; Improved ±0.1% FS BSL; Premium ±0.04% FS BSL (grade by option).
- Output — mV passive/linearised; 4–20 mA; 0–5 V; 0–10 V; 0.5–4.5 V ratiometric; configurable voltage (by electronics option).
- Supply — Depends on output: e.g. mA 7–28 VDC; mV/voltage options typically 2.5–16 VDC (see OEM documentation table).
- Process connection — Multiple pressure connector options (incl. G1/4 depth cone, NPT/UNJF/VCR and others per OEM documentation).
- Electrical connection — Multiple electrical connector options (IP rating depends on connector; demountable options available).
- Wetted / housing — Stainless steel 316L; Hastelloy C276 option; fluids must be compatible with selected materials. Stainless steel construction.
- IP — IP65 to IP68 depending on electrical connector / reference type (see OEM documentation notes).
- Ambient — Operating −55…+125 °C (−67…+257 °F); compensated ranges selectable (e.g. −10…+50 °C).
- Overpressure — High overpressure capability (values depend on range/connector; see OEM documentation).
Common mistakes
- Quoting a single “UNIK 5000” without the full model code — range, pressure type, accuracy grade, output, and connectors are all options.
- Mixing mA supply expectations (7–28 VDC) with mV/voltage excitation (typically 2.5–16 VDC).
- Assuming IP68 on every build; IP is connector- and reference-type dependent (IP65 to IP68).
- Specifying 316L when media need Hastelloy C276 — wetted material is a configuration choice.
- Claiming Ex ia / ATEX/IECEx without the hazardous-area option on the order code.
- Leaving media temperature blank — confirm against the selected compensated range and process duty on the quote.
When to RFQ / what to tell us
- Pressure type (gauge / sealed gauge / absolute / wet-dry or wet-wet DP) and required span + units.
- Accuracy grade (Industrial / Improved / Premium) and output electronics (mA / V / mV / ratiometric).
- Process and electrical connectors; IP need; media chemistry (316L vs Hastelloy C276).
- Operating / compensated temperature range and overpressure expectation.
- Hazardous-area marks required (ATEX/IECEx Ex ia etc.), quantity, ship-to country.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 32260 |
| Brand | Druck |
| Model | UNIK 5000 |
| Product type | transducer |
| Pressure type | gauge / sealed gauge / absolute / wet-dry & wet-wet differential (by config) |
| Measuring range | 70 mbar…700 bar (1…10000 psi) by configuration |
| Accuracy | Industrial ±0.2% FS BSL; Improved ±0.1% FS BSL; Premium ±0.04% FS BSL (grade by option) |
| Output signal | mV passive/linearised; 4–20 mA; 0–5 V; 0–10 V; 0.5–4.5 V ratiometric; configurable voltage (by electronics option) |
| Supply voltage | Depends on output: e.g. mA 7–28 VDC; mV/voltage options typically 2.5–16 VDC (see OEM documentation table) |
| Process connection | Multiple pressure connector options (incl. G1/4 depth cone, NPT/UNJF/VCR and others per OEM documentation) |
| Electrical connection | Multiple electrical connector options (IP rating depends on connector; demountable options available) |
| Wetted materials | Stainless steel 316L; Hastelloy C276 option; fluids must be compatible with selected materials |
| Housing material | Stainless steel construction |
| IP rating | IP65 to IP68 depending on electrical connector / reference type (see OEM documentation notes) |
| Ambient temperature | Operating −55…+125 °C (−67…+257 °F); compensated ranges selectable (e.g. −10…+50 °C) |
| Overpressure limit | High overpressure capability (values depend on range/connector; see OEM documentation) |
| Display | none |
| Approvals | ATEX; IECEx; CE |
| Hazardous area | Optional hazardous-area certifications (e.g. ATEX/IECEx Ex ia); see OEM documentation approvals |
| Notes | Configurable OEM platform (Baker Hughes / Druck). Specs are capability envelope across options; order-specific model code required. Media temperature / burst are not single catalog limits — confirm on quote. |
Documents
FAQ
Q: Is UNIK 5000 one fixed transmitter? A: No. It is a configurable sensing platform. Range, pressure type, accuracy grade, output, connectors, and approvals are selected by model code — send process data so we can lock a build.
Q: Which accuracy grade should I pick? A: Industrial ±0.2% FS BSL, Improved ±0.1% FS BSL, or Premium ±0.04% FS BSL. Match the grade to loop tolerance and cost — state the required %FS in the RFQ.
Q: Which approvals can I claim? A: CE plus optional ATEX/IECEx (e.g. Ex ia) when ordered. Only marks on the datasheet and ordered configuration apply.
Q: What should I send for a quote? A: Pressure type and span, accuracy grade, output and supply, connectors, media, temperature, IP / Ex needs, quantity. Compatible with systems using Druck UNIK 5000 if you need a drop-in check — we do not claim authorized-dealer status.
Links
| Parameter | Value |
|---|---|
| Measuring range | 70 mbar…700 bar (1…10000 psi); gauge / sealed gauge / absolute / wet-dry & wet-wet differential (by config) |
| Accuracy | Industrial ±0.2% FS BSL; Improved ±0.1% FS BSL; Premium ±0.04% FS BSL (grade by option) |
| Accuracy % FS | 0.04 |
| Output | mV passive/linearised; 4–20 mA; 0–5 V; 0–10 V; 0.5–4.5 V ratiometric; configurable voltage (by electronics option) |
| Supply | Depends on output: e.g. mA 7–28 VDC; mV/voltage options typically 2.5–16 VDC (see datasheet table) |
| Process connection | Multiple pressure connector options (incl. G1/4 depth cone, NPT/UNJF/VCR and others per datasheet) |
| Electrical connection | Multiple electrical connector options (IP rating depends on connector; demountable options available) |
| Wetted parts | Stainless steel 316L; Hastelloy C276 option; fluids must be compatible with selected materials |
| Housing | Stainless steel construction |
| Protection | IP65 to IP68 depending on electrical connector / reference type (see datasheet notes) |
| Ambient temperature | Operating −55…+125 °C (−67…+257 °F); compensated ranges selectable (e.g. −10…+50 °C) |
| Pressure type | other |
| Display | none |
| Approvals | ATEX; IECEx; CE |
| Hazardous area | Optional hazardous-area certifications (e.g. ATEX/IECEx Ex ia); see datasheet approvals |
| Notes | Configurable OEM platform (Baker Hughes / Druck). Specs are capability envelope across options; order-specific model code required. |
| Overpressure Limit | High overpressure capability (values depend on range/connector; see datasheet) |