ifm efector

ifm PA3021 Pressure Transmitter

SKU · 23530 · PA3021 · Brand: ifm efector
Available
Quote on request
No online payment · add lines to RFQ BOM

0…250 bar; 4–20 mA; ceramic cell; G1/4; IP68/IP69K. RFQ + selection help.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Measuring range
0…250 bar (0…3625 psi) relative pressure
Accuracy
< ±0.25% span BFSL / < ±0.5% LS; repeatability < 0.1%
Output
4…20 mA analog
Supply
9.6…32 VDC
Process connection
G 1/4 internal thread
Wetted parts
Stainless steel / ceramics / FKM (ceramic measuring cell)
Download datasheet PDF

Fits relative pressure measurement to 250 bar where you need an ifm PA3021 with 4–20 mA output, ceramic measuring cell, G 1/4 internal thread, and IP68/IP69K protection.

Key advantages

  • Range — 0…250 bar (0…3625 psi) relative
  • Output — 4…20 mA; supply 9.6…32 VDC
  • Accuracy — < ±0.25% span BFSL / < ±0.5% LS; repeatability < 0.1%
  • Connection — G 1/4 internal thread
  • Protection — IP68 / IP69K; ceramic cell; pressure rating 400 bar / burst 850 bar

Typical applications

  • Hydraulic and process relative pressure.
  • Washdown installs needing IP69K.
  • Compact G 1/4 transmitter points.

Selection guide

  • Range — 250 bar vs lower PA30xx siblings
  • Thread — G 1/4 internal
  • Media T — −25…90 °C
  • Seals — FKM with ceramic cell

Common mistakes

  • Ordering internal G 1/4 when external PA3521 style is required.
  • Exceeding 400 bar overpressure rating.
  • Ignoring medium temperature limits.

When to RFQ / what to tell us

  1. Media, P, T; thread preference.
  2. Quantity and ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU23530
Brandifm efector
ModelPA3021
Product typePressure Transmitter
Measuring range0…250 bar (0…3625 psi) relative pressure
Output4…20 mA analog
Supply9.6…32 VDC
Accuracy< ±0.25% span BFSL / < ±0.5% LS; repeatability < 0.1%
Process connectionG 1/4 internal thread
Medium temperature−25…90 °C
Ambient−25…80 °C
ProtectionIP68 / IP69K
Pressure rating400 bar; min. burst 850 bar
Wetted materialsStainless steel / ceramics / FKM (ceramic measuring cell)
SensorCeramic measuring cell, relative pressure
Weight0.224 kg

Documents

FAQ

Q: Range? A: 0…250 bar relative.

Q: IP rating? A: IP68 / IP69K.

Q: What should I send for a quote? A: Media/P/T, quantity, ship-to.

Links

ParameterValue
Measuring range0…250 bar (0…3625 psi) relative pressure
Accuracy< ±0.25% span BFSL / < ±0.5% LS; repeatability < 0.1%
Output4…20 mA analog
Supply9.6…32 VDC
Process connectionG 1/4 internal thread
Wetted partsStainless steel / ceramics / FKM (ceramic measuring cell)
Ambient temperature−25…80 °C
Sensor typeCeramic measuring cell, relative pressure
Medium Temperature−25…90 °C
ProtectionIP68 / IP69K
Pressure Rating400 bar; min. burst 850 bar
Weight0.224 kg