ifm efector

ifm PA3521 Pressure Transmitter

SKU · 23533 · PA3521 · Brand: ifm efector
Available
Quote on request
No online payment · add lines to RFQ BOM

0…250 bar; 4–20 mA; ceramic; G1/4 external. RFQ + selection help.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Measuring range
0…250 bar relative pressure
Accuracy
< ±0.25% span BFSL / < ±0.5% LS
Output
4…20 mA analog
Supply
9.6…32 VDC
Process connection
G 1/4 external / M5 internal (DIN 3869-14 FPM seal)
Ambient temperature
−25…80 °C
Download datasheet PDF

Fits relative pressure to 250 bar with external thread where you need an ifm PA3521 ceramic-cell transmitter, 4–20 mA output, and G 1/4 external / M5 internal process connection.

Key advantages

  • Range — 0…250 bar relative
  • Output — 4…20 mA; supply 9.6…32 VDC
  • Accuracy — < ±0.25% span BFSL / < ±0.5% LS
  • Connection — G 1/4 external / M5 internal (DIN 3869-14 FPM seal)
  • Rating — 400 bar; min. burst 850 bar; ceramic measuring cell

Typical applications

  • Hydraulic relative pressure with external G 1/4.
  • Machine builders preferring PA35xx thread style.
  • Liquid (and gas — contact ifm above 25 bar gas).

Selection guide

  • Thread style — External PA3521 vs internal PA3021
  • Range — 250 bar
  • Media — Liquids; gases >25 bar contact ifm
  • Temperature — −25…90 °C medium

Common mistakes

  • Ordering internal-thread PA3021 when external is required.
  • Gas service above 25 bar without ifm confirmation.
  • Wrong seal (FPM) for media.

When to RFQ / what to tell us

  1. Media, P, T; thread preference; quantity; ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU23533
Brandifm efector
ModelPA3521
Product typePressure Transmitter
Measuring range0…250 bar relative pressure
Output4…20 mA analog
Supply9.6…32 VDC
Accuracy< ±0.25% span BFSL / < ±0.5% LS
Process connectionG 1/4 external / M5 internal (DIN 3869-14 FPM seal)
Medium temperature−25…90 °C
Ambient−25…80 °C
ProtectionIP65 / IP67 class family (see datasheet)
Pressure rating400 bar; min. burst 850 bar
SensorCeramic measuring cell, relative pressure
MediaLiquids and gases (gases >25 bar: contact ifm)

Documents

FAQ

Q: PA3521 vs PA3021? A: Same 250 bar class; PA3521 is G 1/4 external, PA3021 internal.

Q: Output? A: 4…20 mA analog.

Q: What should I send for a quote? A: Media/P/T, quantity, ship-to.

Links

ParameterValue
Measuring range0…250 bar relative pressure
Accuracy< ±0.25% span BFSL / < ±0.5% LS
Output4…20 mA analog
Supply9.6…32 VDC
Process connectionG 1/4 external / M5 internal (DIN 3869-14 FPM seal)
Ambient temperature−25…80 °C
Sensor typeCeramic measuring cell, relative pressure
Medium Temperature−25…90 °C
ProtectionIP65 / IP67 class family (see datasheet)
Pressure Rating400 bar; min. burst 850 bar
MediaLiquids and gases (gases >25 bar: contact ifm)