Key parameters

Measuring range
0…10 bar relative pressure
Accuracy
< ±0.25% span BFSL / < ±0.5% LS
Output
4…20 mA analog
Supply
9.6…32 VDC
Process connection
G 1/4 external / M5 internal (DIN 3869-14 FPM seal)
Sensor type
Ceramic measuring cell, relative pressure
Download datasheet PDF

Fits relative pressure to 10 bar with external thread where you need an ifm PA3524 ceramic-cell transmitter, 4–20 mA output, and G 1/4 external / M5 internal connection.

Key advantages

  • Range — 0…10 bar relative
  • Output — 4…20 mA; supply 9.6…32 VDC
  • Accuracy — < ±0.25% span BFSL / < ±0.5% LS
  • Connection — G 1/4 external / M5 internal (DIN 3869-14 FPM seal)
  • Rating — 75 bar; min. burst 150 bar; liquids and gases

Typical applications

  • Low-pressure liquid/gas machine loops.
  • External G 1/4 panel fittings.
  • PA35xx-family standardization at 10 bar.

Selection guide

  • Range — 10 bar vs 250 bar PA3521
  • Thread — External vs internal PA3024
  • Media T — −25…90 °C
  • Electrical class — Protection class III

Common mistakes

  • Using 10 bar unit above its rating.
  • Wrong external vs internal thread choice.
  • Seal incompatibility with media.

When to RFQ / what to tell us

  1. Media, P, T; quantity; ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU23534
Brandifm efector
ModelPA3524
Product typePressure Transmitter
Measuring range0…10 bar relative pressure
Output4…20 mA analog
Supply9.6…32 VDC
Accuracy< ±0.25% span BFSL / < ±0.5% LS
Process connectionG 1/4 external / M5 internal (DIN 3869-14 FPM seal)
Medium temperature−25…90 °C
Pressure rating75 bar; min. burst 150 bar
SensorCeramic measuring cell, relative pressure
MediaLiquids and gases
Protection classIII (electrical)

Documents

FAQ

Q: Range? A: 0…10 bar relative.

Q: Thread? A: G 1/4 external / M5 internal.

Q: What should I send for a quote? A: Media/P/T, quantity, ship-to.

Links

ParameterValue
Measuring range0…10 bar relative pressure
Accuracy< ±0.25% span BFSL / < ±0.5% LS
Output4…20 mA analog
Supply9.6…32 VDC
Process connectionG 1/4 external / M5 internal (DIN 3869-14 FPM seal)
Sensor typeCeramic measuring cell, relative pressure
Medium Temperature−25…90 °C
Pressure Rating75 bar; min. burst 150 bar
MediaLiquids and gases
Protection ClassIII (electrical)