Dwyer Instruments

Dwyer 673 Series Pressure Transmitter

SKU · 24040 · 673 Series · Brand: Dwyer Instruments
Available
Quote on request
No online payment · add lines to RFQ BOM

Compact PT; 0–1 to 1000 psi; ±0.25% BFSL; 4–20 mA; 17-4 PH. RFQ + selection help.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Measuring range
0–1 psi through 0–1000 psi; compound −14.7 to 100 psi (models 673-1…673-10, 673-14; conduit -C versions)
Accuracy
±0.25% BFSL (RSS) including non-linearity, hysteresis and non-repeatability
Output
4–20 mA, 2-wire
Supply
9–30 VDC
Process connection
1/4 in NPT
Wetted parts
17-4 PH stainless steel
Download datasheet PDF

Fits compact industrial pressure points where you need a Dwyer 673 with ±0.25% BFSL accuracy, 4–20 mA output, 17-4 PH SS wetted parts, and ranges from 0–1 to 0–1000 psi (plus compound).

Key advantages

  • Ranges — 0–1 through 0–1000 psi; compound −14.7 to 100 psi
  • Accuracy — ±0.25% BFSL (RSS)
  • Output — 4–20 mA 2-wire; 9–30 VDC; 5 ms response
  • Wetted — 17-4 PH stainless steel; 1/4 in NPT
  • Rugged — Shock 200 g; vibration 20 g; ~2.3 oz

Typical applications

  • OEM machine pressure.
  • Compatible liquid/gas/vapor (material-limited).
  • Tight spaces needing small transmitters.

Selection guide

  • Range / compound — Model chart 673-1…
  • Electrical — Cable vs conduit -C
  • Supply — 9–30 VDC loop
  • Proof — 2× max range

Common mistakes

  • Media incompatible with 17-4 PH.
  • Exceeding 2× pressure limit.
  • Ignoring −40 to 185 °F limits.

When to RFQ / what to tell us

  1. Range, electrical style.
  2. Quantity and ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU24040
BrandDwyer Instruments
Model673 Series
Product typePressure Transmitter
Measuring range0–1 psi through 0–1000 psi; compound −14.7 to 100 psi (models 673-1…673-10, 673-14; conduit -C versions)
Accuracy±0.25% BFSL (RSS) including non-linearity, hysteresis and non-repeatability
Output4–20 mA, 2-wire
Supply9–30 VDC
Wetted materials17-4 PH stainless steel
Temperature limits−40 to 185°F (−40 to 85°C); compensated −40 to 176°F (−40 to 80°C)
Pressure limits2× max range
Response time5 ms
Stability0.5% FS/year
Process connection1/4 in NPT
EnclosureSS and Valox; cable or conduit knockout versions
Weight2.3 oz (65 g)
ApprovalsCE

Documents

FAQ

Q: Accuracy? A: ±0.25% BFSL (RSS).

Q: Wetted material? A: 17-4 PH stainless steel.

Q: What should I send for a quote? A: Range/electrical, quantity, ship-to.

Links

ParameterValue
Measuring range0–1 psi through 0–1000 psi; compound −14.7 to 100 psi (models 673-1…673-10, 673-14; conduit -C versions)
Accuracy±0.25% BFSL (RSS) including non-linearity, hysteresis and non-repeatability
Output4–20 mA, 2-wire
Supply9–30 VDC
Process connection1/4 in NPT
Wetted parts17-4 PH stainless steel
ApprovalsCE
Temperature Limits−40 to 185°F (−40 to 85°C); compensated −40 to 176°F (−40 to 80°C)
Pressure Limits2× max range
Response Time5 ms
Loop Resistance0 to 800 Ω
Stability0.5% FS/year
Shock VibrationShock 200 g; vibration 20 g
EnclosureSS and Valox; cable or conduit knockout versions
Weight2.3 oz (65 g)