Rosemount 2088 Pressure Transmitter
Absolute/gauge in-line transmitter. Ranges to 10000 psi, ±0.075% span (±0.065% P8), HART. RFQ + selection help.
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Fits continuous absolute or gauge measurement on process loops that need a compact in-line transmitter, 4–20 mA HART (or low-power 1–5 Vdc HART), and up to 50:1 rangeability.
Key advantages
- Gauge and absolute — −14.7…10000 psi gauge; 0…10000 psi absolute (ranges 1–5).
- ±0.075% of span std — ±0.065% with high-accuracy option P8 (to 10:1 turndown).
- HART 5/7 outputs — 4–20 mA HART (code S) or 1–5 Vdc Low Power HART (code N); HR7 for HART 7.
- Flexible process connections — ½–14 NPT female std; DIN G½ / M20×1.5 / RC ½ options.
Typical applications
- Compact absolute or gauge pressure points on process skids.
- Loops standardized on Rosemount 2088 with HART or low-power HART.
- Installations picking conduit entry and process connection at order.
Selection guide
- Pressure type & range — Gauge −14.7…10000 psi; absolute 0…10000 psi (ranges 1–5). Pick the range that covers your calibrated span.
- Accuracy — ±0.075% of calibrated span standard; ±0.065% with high-accuracy option P8 (to 10:1 turndown). Rangeability 50:1.
- Output — 4–20 mA HART (code S); 1–5 Vdc Low Power HART (code N); HART 5 default / HART 7 option HR7.
- Supply — 10.5–42.4 Vdc no load (4–20 mA); 5.8–28 V for Low Power.
- Process connection — ½–14 NPT female (std); DIN 16288 G½ male; M20×1.5 male; RC ½ female.
- Electrical entries — ½–14 NPT, M20×1.5, or G½ conduit entry.
- Wetted materials — 316L SST or Alloy C-276 isolating diaphragm / process connection; silicone or inert fill.
- Overpressure / burst — Overpressure: Range 1 120 psig; Ranges 2–4 2× URL; Range 5 15000 psi. Burst: Ranges 1–4 11000 psi; Range 5 26000 psi.
- Process / ambient temperature — Silicone fill −40…+121 °C; inert −30…+121 °C (vacuum service limits apply). Ambient −40…+85 °C (with LCD −40…+80 °C).
- Housing & IP — Aluminum (low-copper), painted polyurethane. NEMA Type 4X, IP66, IP68 when properly installed.
Common mistakes
- Ordering standard ±0.075% when the loop needs option P8 (±0.065% to 10:1 turndown) — high accuracy is an order option.
- Mixing Low Power supply (5.8–28 V) with a 4–20 mA HART loop design (10.5–42.4 Vdc no load).
- Ignoring overpressure/burst by range (Range 1 overpressure only 120 psig; Range 5 burst 26000 psi) — match the range code to the process upset case.
- Specifying 316L when media need Alloy C-276 — wetted material is a model-code choice.
- Claiming hazardous-area coverage without the matching E/I/N/K option codes on the quote.
- Leaving vacuum-service limits blank when fill is inert (−30…+121 °C) or absolute under vacuum.
When to RFQ / what to tell us
- Pressure type (gauge / absolute) and required calibrated span + units.
- Accuracy need (std ±0.075% vs P8 ±0.065%) and HART 5 vs HART 7 (HR7).
- Output code S (4–20 mA) vs N (1–5 Vdc Low Power) and available supply.
- Media, temperature, fill (silicone or inert), wetted materials, process connection.
- Overpressure expectation, IP / area class, display/LOI, manifolds/remote seals, quantity, ship-to country.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 24613 |
| Brand | Rosemount |
| Model | 2088 |
| Product type | transmitter |
| Pressure type | absolute / gauge (by range code) |
| Measuring range | Gauge −14.7…10000 psi; absolute 0…10000 psi (ranges 1–5) |
| Accuracy | ±0.075% of calibrated span standard; ±0.065% with high-accuracy option P8 (to 10:1 turndown) |
| Output signal | 4–20 mA HART (code S); 1–5 Vdc Low Power HART (code N); HART 5 default / HART 7 option HR7 |
| Supply voltage | 10.5–42.4 Vdc no load (4–20 mA); 5.8–28 V for Low Power |
| Process connection | ½–14 NPT female (std); DIN 16288 G½ male; M20×1.5 male; RC ½ female |
| Electrical connection | ½–14 NPT, M20×1.5, or G½ conduit entry |
| Wetted materials | 316L SST or Alloy C-276 isolating diaphragm / process connection; silicone or inert fill |
| Housing material | Aluminum (low-copper); painted polyurethane |
| IP rating | NEMA Type 4X, IP66, IP68 when properly installed |
| Media temperature | Silicone fill −40…+121 °C; inert −30…+121 °C (vacuum service limits apply) |
| Ambient temperature | −40…+85 °C (with LCD −40…+80 °C) |
| Overpressure limit | Range 1: 120 psig; Ranges 2–4: 2× URL; Range 5: 15000 psi |
| Burst pressure | Ranges 1–4: 11000 psi; Range 5: 26000 psi |
| Display | Optional fully configurable LCD; LOI (M4) |
| Communication | HART (Rev 5/7) |
| Approvals | ATEX; IECEx; FM; CSA; CE |
| Hazardous area | ATEX Flameproof/IS/Type n/Dust and multi-approvals (E/I/N/K option codes) |
| Diaphragm seal | Optional remote seals; assemble-to manifolds |
| Fill fluid | Silicone (std) or inert |
| Mounting | Direct in-line; manifolds available |
| Weight | Approx. 2.44 lb (1.11 kg) output S ranges 1–4; ~3 lb (1.4 kg) output N or range 5 |
| Notes | Specs from Emerson PDS 00813-0100-4690 Rev QC (June 2024). Rangeability 50:1. |
Documents
FAQ
Q: Gauge or absolute — which 2088 configuration do I need? A: Gauge when the low side sees atmosphere; absolute when you need absolute zero. Ranges 1–5 cover both — state the type and span in the RFQ.
Q: When do I need option P8? A: When the loop needs ±0.065% of calibrated span (to 10:1 turndown) instead of the standard ±0.075%. Call out P8 in the RFQ if that accuracy is required.
Q: Which approvals can I claim? A: Only those in the OEM documentation and ordered codes: ATEX, IECEx, FM, CSA, CE. Hazardous-area protection is selected by E/I/N/K option codes.
Q: What should I send for a quote? A: Pressure type and span, accuracy option, output S vs N, media and temperature, wetted materials, connection, supply, area class, display, quantity. Compatible with systems using Rosemount 2088 if you need a drop-in check — we do not claim authorized-dealer status.
Links
| Parameter | Value |
|---|---|
| Measuring range | Gauge −14.7…10000 psi; absolute 0…10000 psi (ranges 1–5) |
| Accuracy | ±0.075% of calibrated span standard; ±0.065% with high-accuracy option P8 (to 10:1 turndown) |
| Accuracy % FS | 0.065 |
| Output | 4–20 mA HART (code S); 1–5 Vdc Low Power HART (code N); HART 5 default / HART 7 option HR7 |
| Supply | 10.5–42.4 Vdc no load (4–20 mA); 5.8–28 V for Low Power |
| Process connection | ½–14 NPT female (std); DIN 16288 G½ male; M20×1.5 male; RC ½ female |
| Electrical connection | ½–14 NPT, M20×1.5, or G½ conduit entry |
| Wetted parts | 316L SST or Alloy C-276 isolating diaphragm / process connection; silicone or inert fill |
| Housing | Aluminum (low-copper); painted polyurethane |
| Protection | NEMA Type 4X, IP66, IP68 when properly installed |
| Media temperature | Silicone fill −40…+121 °C; inert −30…+121 °C (vacuum service limits apply) |
| Ambient temperature | −40…+85 °C (with LCD −40…+80 °C) |
| Pressure type | other |
| Display | Optional fully configurable LCD; LOI (M4) |
| Communication | HART (Rev 5/7) |
| Approvals | ATEX; IECEx; FM; CSA; CE |
| Hazardous area | ATEX Flameproof/IS/Type n/Dust and multi-approvals (E*/I*/N*/K* option codes) |
| Fill fluid | Silicone (std) or inert |
| Mounting | Direct in-line; manifolds available |
| Notes | Specs from Emerson PDS 00813-0100-4690 Rev QC (June 2024). Rangeability 50:1. |
| Overpressure Limit | Range 1: 120 psig; Ranges 2–4: 2× URL; Range 5: 15000 psi |
| Burst Pressure | Ranges 1–4: 11000 psi; Range 5: 26000 psi |
| Diaphragm Seal | Optional remote seals; assemble-to manifolds |
| Weight | Approx. 2.44 lb (1.11 kg) output S ranges 1–4; ~3 lb (1.4 kg) output N or range 5 |