RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Measuring range
Gauge −14.7…10000 psi; absolute 0…10000 psi (ranges 1–5)
Accuracy
±0.075% of calibrated span standard; ±0.065% with high-accuracy option P8 (to 10:1 turndown)
Accuracy % FS
0.065
Output
4–20 mA HART (code S); 1–5 Vdc Low Power HART (code N); HART 5 default / HART 7 option HR7
Supply
10.5–42.4 Vdc no load (4–20 mA); 5.8–28 V for Low Power
Process connection
½–14 NPT female (std); DIN 16288 G½ male; M20×1.5 male; RC ½ female
Download datasheet PDF

Fits continuous absolute or gauge measurement on process loops that need a compact in-line transmitter, 4–20 mA HART (or low-power 1–5 Vdc HART), and up to 50:1 rangeability.

Key advantages

  • Gauge and absolute — −14.7…10000 psi gauge; 0…10000 psi absolute (ranges 1–5).
  • ±0.075% of span std — ±0.065% with high-accuracy option P8 (to 10:1 turndown).
  • HART 5/7 outputs — 4–20 mA HART (code S) or 1–5 Vdc Low Power HART (code N); HR7 for HART 7.
  • Flexible process connections — ½–14 NPT female std; DIN G½ / M20×1.5 / RC ½ options.

Typical applications

  • Compact absolute or gauge pressure points on process skids.
  • Loops standardized on Rosemount 2088 with HART or low-power HART.
  • Installations picking conduit entry and process connection at order.

Selection guide

  • Pressure type & range — Gauge −14.7…10000 psi; absolute 0…10000 psi (ranges 1–5). Pick the range that covers your calibrated span.
  • Accuracy — ±0.075% of calibrated span standard; ±0.065% with high-accuracy option P8 (to 10:1 turndown). Rangeability 50:1.
  • Output — 4–20 mA HART (code S); 1–5 Vdc Low Power HART (code N); HART 5 default / HART 7 option HR7.
  • Supply — 10.5–42.4 Vdc no load (4–20 mA); 5.8–28 V for Low Power.
  • Process connection — ½–14 NPT female (std); DIN 16288 G½ male; M20×1.5 male; RC ½ female.
  • Electrical entries — ½–14 NPT, M20×1.5, or G½ conduit entry.
  • Wetted materials — 316L SST or Alloy C-276 isolating diaphragm / process connection; silicone or inert fill.
  • Overpressure / burst — Overpressure: Range 1 120 psig; Ranges 2–4 2× URL; Range 5 15000 psi. Burst: Ranges 1–4 11000 psi; Range 5 26000 psi.
  • Process / ambient temperature — Silicone fill −40…+121 °C; inert −30…+121 °C (vacuum service limits apply). Ambient −40…+85 °C (with LCD −40…+80 °C).
  • Housing & IP — Aluminum (low-copper), painted polyurethane. NEMA Type 4X, IP66, IP68 when properly installed.

Common mistakes

  • Ordering standard ±0.075% when the loop needs option P8 (±0.065% to 10:1 turndown) — high accuracy is an order option.
  • Mixing Low Power supply (5.8–28 V) with a 4–20 mA HART loop design (10.5–42.4 Vdc no load).
  • Ignoring overpressure/burst by range (Range 1 overpressure only 120 psig; Range 5 burst 26000 psi) — match the range code to the process upset case.
  • Specifying 316L when media need Alloy C-276 — wetted material is a model-code choice.
  • Claiming hazardous-area coverage without the matching E/I/N/K option codes on the quote.
  • Leaving vacuum-service limits blank when fill is inert (−30…+121 °C) or absolute under vacuum.

When to RFQ / what to tell us

  1. Pressure type (gauge / absolute) and required calibrated span + units.
  2. Accuracy need (std ±0.075% vs P8 ±0.065%) and HART 5 vs HART 7 (HR7).
  3. Output code S (4–20 mA) vs N (1–5 Vdc Low Power) and available supply.
  4. Media, temperature, fill (silicone or inert), wetted materials, process connection.
  5. Overpressure expectation, IP / area class, display/LOI, manifolds/remote seals, quantity, ship-to country.

Request a Quote · Get selection help

Specs

SpecValue
SKU24613
BrandRosemount
Model2088
Product typetransmitter
Pressure typeabsolute / gauge (by range code)
Measuring rangeGauge −14.7…10000 psi; absolute 0…10000 psi (ranges 1–5)
Accuracy±0.075% of calibrated span standard; ±0.065% with high-accuracy option P8 (to 10:1 turndown)
Output signal4–20 mA HART (code S); 1–5 Vdc Low Power HART (code N); HART 5 default / HART 7 option HR7
Supply voltage10.5–42.4 Vdc no load (4–20 mA); 5.8–28 V for Low Power
Process connection½–14 NPT female (std); DIN 16288 G½ male; M20×1.5 male; RC ½ female
Electrical connection½–14 NPT, M20×1.5, or G½ conduit entry
Wetted materials316L SST or Alloy C-276 isolating diaphragm / process connection; silicone or inert fill
Housing materialAluminum (low-copper); painted polyurethane
IP ratingNEMA Type 4X, IP66, IP68 when properly installed
Media temperatureSilicone fill −40…+121 °C; inert −30…+121 °C (vacuum service limits apply)
Ambient temperature−40…+85 °C (with LCD −40…+80 °C)
Overpressure limitRange 1: 120 psig; Ranges 2–4: 2× URL; Range 5: 15000 psi
Burst pressureRanges 1–4: 11000 psi; Range 5: 26000 psi
DisplayOptional fully configurable LCD; LOI (M4)
CommunicationHART (Rev 5/7)
ApprovalsATEX; IECEx; FM; CSA; CE
Hazardous areaATEX Flameproof/IS/Type n/Dust and multi-approvals (E/I/N/K option codes)
Diaphragm sealOptional remote seals; assemble-to manifolds
Fill fluidSilicone (std) or inert
MountingDirect in-line; manifolds available
WeightApprox. 2.44 lb (1.11 kg) output S ranges 1–4; ~3 lb (1.4 kg) output N or range 5
NotesSpecs from Emerson PDS 00813-0100-4690 Rev QC (June 2024). Rangeability 50:1.

Documents

FAQ

Q: Gauge or absolute — which 2088 configuration do I need? A: Gauge when the low side sees atmosphere; absolute when you need absolute zero. Ranges 1–5 cover both — state the type and span in the RFQ.

Q: When do I need option P8? A: When the loop needs ±0.065% of calibrated span (to 10:1 turndown) instead of the standard ±0.075%. Call out P8 in the RFQ if that accuracy is required.

Q: Which approvals can I claim? A: Only those in the OEM documentation and ordered codes: ATEX, IECEx, FM, CSA, CE. Hazardous-area protection is selected by E/I/N/K option codes.

Q: What should I send for a quote? A: Pressure type and span, accuracy option, output S vs N, media and temperature, wetted materials, connection, supply, area class, display, quantity. Compatible with systems using Rosemount 2088 if you need a drop-in check — we do not claim authorized-dealer status.

Links

ParameterValue
Measuring rangeGauge −14.7…10000 psi; absolute 0…10000 psi (ranges 1–5)
Accuracy±0.075% of calibrated span standard; ±0.065% with high-accuracy option P8 (to 10:1 turndown)
Accuracy % FS0.065
Output4–20 mA HART (code S); 1–5 Vdc Low Power HART (code N); HART 5 default / HART 7 option HR7
Supply10.5–42.4 Vdc no load (4–20 mA); 5.8–28 V for Low Power
Process connection½–14 NPT female (std); DIN 16288 G½ male; M20×1.5 male; RC ½ female
Electrical connection½–14 NPT, M20×1.5, or G½ conduit entry
Wetted parts316L SST or Alloy C-276 isolating diaphragm / process connection; silicone or inert fill
HousingAluminum (low-copper); painted polyurethane
ProtectionNEMA Type 4X, IP66, IP68 when properly installed
Media temperatureSilicone fill −40…+121 °C; inert −30…+121 °C (vacuum service limits apply)
Ambient temperature−40…+85 °C (with LCD −40…+80 °C)
Pressure typeother
DisplayOptional fully configurable LCD; LOI (M4)
CommunicationHART (Rev 5/7)
ApprovalsATEX; IECEx; FM; CSA; CE
Hazardous areaATEX Flameproof/IS/Type n/Dust and multi-approvals (E*/I*/N*/K* option codes)
Fill fluidSilicone (std) or inert
MountingDirect in-line; manifolds available
NotesSpecs from Emerson PDS 00813-0100-4690 Rev QC (June 2024). Rangeability 50:1.
Overpressure LimitRange 1: 120 psig; Ranges 2–4: 2× URL; Range 5: 15000 psi
Burst PressureRanges 1–4: 11000 psi; Range 5: 26000 psi
Diaphragm SealOptional remote seals; assemble-to manifolds
WeightApprox. 2.44 lb (1.11 kg) output S ranges 1–4; ~3 lb (1.4 kg) output N or range 5