Rosemount

Rosemount 2051C Pressure Transmitter

SKU · 24642 · 2051C · Brand: Rosemount
Available
Quote on request
No online payment · add lines to RFQ BOM

Coplanar pressure transmitter for DP/gage loops. Ranges 1–5, up to ±0.05% span, HART/FF/PA/WirelessHART. RFQ + selection help.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Measuring range
Differential −25…+25 inH2O to −2000…+2000 psi; gauge −25…+25 inH2O to −14.2…2000 psi (ranges 1–5)
Accuracy
Up to ±0.065% of span (std); high-accuracy option P8 up to ±0.05% of span / 0.05% reference accuracy
Accuracy % FS
0.05
Output
4–20 mA HART; FOUNDATION Fieldbus; PROFIBUS PA; WirelessHART (IEC 62591)
Supply
10.5–42.4 VDC (4–20 mA HART, no load)
Process connection
Coplanar process connection; 1/4–18 NPT on flanges/manifolds; alternate process connections available
Download datasheet PDF

Fits continuous differential or gage pressure loops that need a coplanar process connection and a configurable 4–20 mA HART (or Fieldbus / PROFIBUS / WirelessHART) output.

Key advantages

  • Coplanar DP/GP platform — differential to ±2000 psi; gauge to 2000 psi across published range codes.
  • Up to ±0.05% span — standard to ±0.065%; high-accuracy option P8 to ±0.05% / 0.05% reference.
  • Protocol choice — 4–20 mA HART, FOUNDATION Fieldbus, PROFIBUS PA, or WirelessHART.
  • Manifold-ready coplanar — 1/4–18 NPT on flanges/manifolds with broad wetted-material options.

Typical applications

  • DP flow, filter, and level applications on coplanar manifolds.
  • Gauge-pressure points sharing the 2051C platform and spare parts.
  • Plants standardized on HART, FF, PA, or WirelessHART hosts.

Selection guide

  • Pressure type & range — Differential −25…+25 inH2O to −2000…+2000 psi; gauge −25…+25 inH2O to −14.2…2000 psi (ranges 1–5). Pick the range code that covers your calibrated span.
  • Accuracy — Up to ±0.065% of span (std); high-accuracy option P8 up to ±0.05% of span / 0.05% reference accuracy.
  • Output / protocol — 4–20 mA HART; FOUNDATION Fieldbus; PROFIBUS PA; WirelessHART (IEC 62591). Confirm DCS/PLC protocol before ordering.
  • Supply — 10.5–42.4 VDC (4–20 mA HART, no load). Check loop resistance and barrier drop.
  • Process connection — Coplanar process connection; 1/4–18 NPT on flanges/manifolds; alternate process connections available.
  • Wetted materials — 316L SST / Alloy C-276 and other process-connection / isolator options per PDS. Match media chemistry and fill fluid.
  • Ambient — Continuous ambient −40…185 °F (−40…85 °C) per PDS life note; see performance ambient-effect tables.
  • Housing & IP — Aluminum or SST (CF-3M / 316L cast) or engineered polymer (code P). NEMA 4X, IP66, IP68 when properly installed (polymer housing also IP66/67/68).
  • Electrical — Terminal block in field housing; conduit entries per housing option.
  • Display — Optional LOI / LCD.

Common mistakes

  • Ordering a range code whose upper range limit is far above the working span — you lose resolution at the bottom of the scale.
  • Specifying 316L when media need Alloy C-276 or another isolator — wetted material is a model-code choice.
  • Mixing Fieldbus/PROFIBUS/WirelessHART expectations with a 4–20 mA HART loop design and 10.5–42.4 VDC supply assumptions.
  • Claiming SIL or hazardous-area coverage without the matching order codes and certificates on the quote.
  • Assuming every housing meets the same IP line; polymer (code P) and metal housings differ — check the order code against the PDS.
  • Leaving media temperature / overpressure blank in the RFQ — those limits are configuration-dependent and must be confirmed on the quote for the chosen order codes.

When to RFQ / what to tell us

  1. Pressure type (differential / gage) and required calibrated span + units.
  2. Media, process temperature, and preferred fill (silicone or other).
  3. Wetted materials and coplanar / flange / manifold connection.
  4. Output protocol and available supply voltage / loop load.
  5. Ambient, IP needs, and hazardous-area / SIL marks required.
  6. Display, remote seal / manifold yes/no, quantity, ship-to country.

Request a Quote · Get selection help

Specs

SpecValue
SKU24642
BrandRosemount
Model2051C
Product typetransmitter
Pressure typedifferential (family also gage by range code)
Measuring rangeDifferential −25…+25 inH2O to −2000…+2000 psi; gauge −25…+25 inH2O to −14.2…2000 psi (ranges 1–5)
AccuracyUp to ±0.065% of span (std); high-accuracy option P8 up to ±0.05% of span / 0.05% reference accuracy
Output signal4–20 mA HART; FOUNDATION Fieldbus; PROFIBUS PA; WirelessHART (IEC 62591)
Supply voltage10.5–42.4 VDC (4–20 mA HART, no load)
Process connectionCoplanar process connection; 1/4–18 NPT on flanges/manifolds; alternate process connections available
Electrical connectionTerminal block in field housing; conduit entries per housing option
Wetted materials316L SST / Alloy C-276 and other process-connection / isolator options per PDS
Housing materialAluminum or SST (CF-3M / 316L cast) or engineered polymer (code P)
IP ratingNEMA 4X, IP66, IP68 when properly installed (polymer housing also IP66/67/68)
Ambient temperatureContinuous ambient −40…185 °F (−40…85 °C) per PDS life note; see performance ambient-effect tables
DisplayOptional LOI / LCD
CommunicationHART; FOUNDATION Fieldbus; PROFIBUS PA; WirelessHART
ApprovalsATEX; IECEx; FM; CSA; SIL2; SIL3; CE
Hazardous areaMultiple regional hazardous-location approvals in PDS Product certifications section (order-code dependent)
Diaphragm sealRemote seal / manifold / primary-element assemblies available on Coplanar platform
Fill fluidSilicone and other fill options per ordering
MountingCoplanar direct mount to manifolds, seals, or primary flow elements
NotesSKU is 2051C (measurement type D differential or G gage). Ranges and materials are order-code configurable. Specs from Emerson PDS 00813-0100-4101 Rev RG (March 2026). Media temperature and overpressure are not single catalog limits — confirm on quote.

Documents

FAQ

Q: DP or gage — which 2051C configuration do I need? A: Match the process reference. Differential for orifice/filter/level across a tap pair; gage when the low side sees atmosphere. Range codes 1–5 cover both — state the type and span in the RFQ.

Q: Is ±0.05% of span always available? A: High-accuracy option P8 is up to ±0.05% of span / 0.05% reference accuracy. Standard accuracy is up to ±0.065% of span. Lock the option with the accuracy your loop needs.

Q: Which approvals can I claim on the nameplate? A: Only those in the OEM documentation and ordered codes: ATEX, IECEx, FM, CSA, SIL2, SIL3, CE. Hazardous-location protection is order-code dependent.

Q: What should I send for a quote? A: Pressure type and span, media and temperature, wetted materials, process connection, protocol and supply, IP / area class, display and mounting, quantity. Compatible with systems using Rosemount 2051C if you need a drop-in check — we do not claim authorized-dealer status.

Links

ParameterValue
Measuring rangeDifferential −25…+25 inH2O to −2000…+2000 psi; gauge −25…+25 inH2O to −14.2…2000 psi (ranges 1–5)
AccuracyUp to ±0.065% of span (std); high-accuracy option P8 up to ±0.05% of span / 0.05% reference accuracy
Accuracy % FS0.05
Output4–20 mA HART; FOUNDATION Fieldbus; PROFIBUS PA; WirelessHART (IEC 62591)
Supply10.5–42.4 VDC (4–20 mA HART, no load)
Process connectionCoplanar process connection; 1/4–18 NPT on flanges/manifolds; alternate process connections available
Electrical connectionTerminal block in field housing; conduit entries per housing option
Wetted parts316L SST / Alloy C-276 and other process-connection / isolator options per PDS
HousingAluminum or SST (CF-3M / 316L cast) or engineered polymer (code P)
ProtectionNEMA 4X, IP66, IP68 when properly installed (polymer housing also IP66/67/68)
Ambient temperatureContinuous ambient −40…185 °F (−40…85 °C) per PDS life note; see performance ambient-effect tables
Pressure typedifferential
DisplayOptional LOI / LCD
CommunicationHART; FOUNDATION Fieldbus; PROFIBUS PA; WirelessHART
ApprovalsATEX; IECEx; FM; CSA; SIL2; SIL3; CE
Hazardous areaMultiple regional hazardous-location approvals in PDS Product certifications section (order-code dependent)
Fill fluidSilicone and other fill options per ordering
MountingCoplanar direct mount to manifolds, seals, or primary flow elements
NotesSKU is 2051C (measurement type D differential or G gage). Ranges and materials are order-code configurable.
Diaphragm SealRemote seal / manifold / primary-element assemblies available on Coplanar platform