Image unavailable
Image unavailable
Rosemount
Rosemount 2051T In-Line Pressure Transmitter
Quote on request
No online payment · add lines to RFQ BOM
2051T in-line; to 10,000 psi; 0.05% option; multi-protocol; SIL. RFQ + selection help.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Measuring range
Gauge −5…+5 to −14.7…+10,000 psi; absolute 0…30 to 0…10,000 psia (ranges 0–5)
Accuracy
Up to ±0.05% of span (high-accuracy option); standard performance per PDS 00813-0100-4101 Rev RG
Accuracy % FS
0.05
Output
4–20 mA HART; FOUNDATION Fieldbus; PROFIBUS PA; WirelessHART
Supply
Per output code in PDS 00813-0100-4101
Process connection
½–14 NPT female; G½ A DIN 16288 male; autoclave F-250-C (range 5)
Fits in-line gauge/absolute pressure where you need a Rosemount 2051T with ranges to 10,000 psi, up to ±0.05% of span high-accuracy option, and HART/Fieldbus/PROFIBUS/WirelessHART protocols.
Key advantages
- Ranges — Gauge −5…+5 to −14.7…+10,000 psi; absolute 0…30 to 0…10,000 psia
- Accuracy — Up to ±0.05% of span (high-accuracy option)
- Protocols — 4–20 mA HART; FOUNDATION Fieldbus; PROFIBUS PA; WirelessHART
- Connection — ½–14 NPT; G½ A; autoclave F-250-C (range 5)
- Options — LOI; SIL 2/3; 316L / Alloy C-276 / gold-plated diaphragms
Typical applications
- In-line process gauge/absolute pressure.
- LOI field configuration.
- SIL-rated 2051T loops.
Selection guide
- Gauge vs absolute / range
- Accuracy option — Standard vs 0.05%
- Protocol / LOI
- Diaphragm / Ex — Materials and area class
Common mistakes
- Confusing with 2051 Coplanar DP.
- Wrong autoclave connection on high ranges.
- Skipping SIL option code.
When to RFQ / what to tell us
- G/A, range, protocol, materials.
- LOI/SIL; quantity; ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 24683 |
| Brand | Rosemount / Emerson |
| Model | 2051T |
| Product type | Pressure Transmitter |
| Measuring range | Gauge −5…+5 to −14.7…+10,000 psi; absolute 0…30 to 0…10,000 psia (ranges 0–5) |
| Accuracy | Up to ±0.05% of span (high-accuracy option); standard performance per PDS 00813-0100-4101 Rev RG |
| Output | 4–20 mA HART; FOUNDATION Fieldbus; PROFIBUS PA; WirelessHART |
| Process connection | ½–14 NPT female; G½ A DIN 16288 male; autoclave F-250-C (range 5) |
| Wetted materials | 316L SST; Alloy C-276; gold-plated 316L options |
| Housing | Aluminum / SST housing codes per PDS |
| IP rating | IP66/IP68 / NEMA Type 4X (housing-dependent) |
| Pressure type | gauge |
| Display | Optional Local Operator Interface (LOI) |
| Communication | HART; FOUNDATION Fieldbus; PROFIBUS PA; WirelessHART |
| Approvals | SIL 2/3 IEC 61508; hazardous-location approvals by option code |
| Mounting | In-line direct process mount |
Documents
FAQ
Q: Max pressure? A: Up to 10,000 psi depending on range code.
Q: High accuracy? A: Up to ±0.05% of span option.
Q: What should I send for a quote? A: Type/range/protocol, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Measuring range | Gauge −5…+5 to −14.7…+10,000 psi; absolute 0…30 to 0…10,000 psia (ranges 0–5) |
| Accuracy | Up to ±0.05% of span (high-accuracy option); standard performance per PDS 00813-0100-4101 Rev RG |
| Accuracy % FS | 0.05 |
| Output | 4–20 mA HART; FOUNDATION Fieldbus; PROFIBUS PA; WirelessHART |
| Supply | Per output code in PDS 00813-0100-4101 |
| Process connection | ½–14 NPT female; G½ A DIN 16288 male; autoclave F-250-C (range 5) |
| Electrical connection | Terminals in housing; optional LOI (M4) |
| Wetted parts | 316L SST; Alloy C-276; gold-plated 316L options |
| Housing | Aluminum / SST housing codes per PDS |
| Protection | IP66/IP68 / NEMA Type 4X (housing-dependent) |
| Media temperature | Per sensor/fill tables in PDS |
| Ambient temperature | Per electronics tables in PDS |
| Pressure type | gauge |
| Display | Optional Local Operator Interface (LOI) |
| Communication | HART; FOUNDATION Fieldbus; PROFIBUS PA; WirelessHART |
| Approvals | SIL 2/3 IEC 61508; hazardous-location approvals by option code |
| Hazardous area | IS/XP/Ex options per product certification codes |
| Fill fluid | Silicone or inert |
| Mounting | In-line direct process mount |
| Notes | Specs from Emerson PDS 00813-0100-4101 covering Rosemount 2051T In-line ordering information. |
| Overpressure Limit | Per range table in PDS 00813-0100-4101 |