Keller

Keller 33X-Ed / 35X-Ed Flameproof Pressure Transmitter

SKU · 40895 · 33 X Ed / 35 X Ed · Brand: Keller
Available
Quote on request
No online payment · add lines to RFQ BOM

Keller 33X/35X-Ed: Ex db; ±0.05% FS; RS485/4–20 mA/0–10 V; to 300 bar. RFQ.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Measuring range
Absolute/gauge 0.1–300 bar class; standard FS −1…1 / 1 / 3 / 10 / 30 / 100 / 200 / 300 bar (series-dependent)
Output
4…20 mA (2-wire) or 0…10 V (3-wire) plus RS485 (KELLER Bus / MODBUS RTU)
Supply
8…32 VDC (2-wire); 13…32 VDC (3-wire); 3.2…32 VDC (digital)
Process connection
G 1/4", G 1/2", G 3/4", 1/2"-14 NPT, 1/4"-18 NPT
Electrical connection
PUR cable 2 m (PE sheath; reference tube for gauge)
Wetted parts
Stainless steel 1.4435 (316L), Viton®
Download datasheet PDF

Fits hazardous-area precision pressure where you need a Keller 33X-Ed or 35X-Ed—flameproof Ex db transmitters with ±0.05% FS digital accuracy, RS485 plus 4–20 mA or 0–10 V, covering about 0.1–300 bar (33X-Ed) or 0.1–100 bar front-flush (35X-Ed).

Key advantages

  • Ex — Group II flameproof Ex db IIC T6…T4 class
  • Accuracy — ±0.05% FS digital; TEB ±0.1% FS (−10…80 °C)
  • Ranges — ~0.1–300 bar (33X-Ed); ~0.1–100 bar (35X-Ed)
  • Outputs — RS485 Modbus/Keller Bus; 4–20 mA; 0–10 V
  • Wetted — 316L / Viton class

Typical applications

  • Ex-rated process pressure.
  • Front-flush sticky media (35X-Ed).
  • Precision hazloc indication.

Selection guide

  • 33X vs 35X
  • Range / connection
  • Analog vs digital primary

Common mistakes

  • Wrong Ex temperature class.
  • Analog disturbance during RS485 talk.
  • Gauge vs absolute mix-up.

When to RFQ / what to tell us

  1. Series, range, output, Ex docs.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU40895
BrandKeller
Model33X-Ed / 35X-Ed
Product typePressure Transmitter
TypeFlameproof piezoresistive pressure transmitter (33X-Ed / 35X-Ed)
RangesAbout 0.1–300 bar (33X-Ed); 0.1–100 bar (35X-Ed front-flush class)
Accuracy±0.05% FS digital @ RT; error band ±0.05% FS (10…40 °C); ±0.1% FS (−10…80 °C)
OutputsRS485 (Keller Bus / Modbus RTU); 4–20 mA; 0–10 V
ExGroup II flameproof Ex db IIC T6…T4 class

Documents

FAQ

Q: Accuracy? A: ±0.05% FS digital at room temperature class.

Q: Ex? A: Flameproof Ex db Group II class.

Q: What should I send for a quote? A: Series/range/output, quantity, ship-to.

Links

ParameterValue
Measuring rangeAbsolute/gauge 0.1–300 bar class; standard FS −1…1 / 1 / 3 / 10 / 30 / 100 / 200 / 300 bar (series-dependent)
Output4…20 mA (2-wire) or 0…10 V (3-wire) plus RS485 (KELLER Bus / MODBUS RTU)
Supply8…32 VDC (2-wire); 13…32 VDC (3-wire); 3.2…32 VDC (digital)
Process connectionG 1/4", G 1/2", G 3/4", 1/2"-14 NPT, 1/4"-18 NPT
Electrical connectionPUR cable 2 m (PE sheath; reference tube for gauge)
Wetted partsStainless steel 1.4435 (316L), Viton®
Accuracy Digital33X-Ed/35X-Ed digital: typ. 0.02% FS @ RT; error band 0.05% FS (10…40 °C), 0.1% FS (−10…80 °C)
Accuracy Analog33X-Ed/35X-Ed analog: typ. 0.03% FS @ RT; error band 0.1% FS (10…40 °C)
InterfaceRS485 half-duplex 9600 / 115200 baud; up to 128 bus subscribers
Ex ClassificationII 2 G Ex db IIC T6 to T4 Gb; EPS 22 ATEX 1 007X; IECEx EPS 22.0002X; UKEX
Temperature LimitsStorage/operating −30…100 °C (33/35X-Ed); Ta limits per T-class to +100 °C (T4)
Long Term Stability0.1% FS typ. (FS > 1 bar); 1 mbar typ. (FS ≤ 1 bar)
HousingPressure-proof / flameproof enclosure for Group II hazardous areas
FamilySeries 33X-Ed (G1/4 body) / 35X-Ed (flush/G1/2 style) digital X-line transmitters