Key parameters
Fits panel-mounted single-loop temperature and process control where you need precision 0.1% inputs, programmable ramp/soak profiles, and native Ethernet connectivity.
Key advantages
- Precision 0.1% inputs — meets AMS2750F and CQI-9 accuracy requirements per OEM docs.
- Up to 20 ramp/soak profiles — programmable single-loop temperature/process control.
- Native Ethernet — RJ45 with Modbus, EtherNet/IP, BACnet; Achilles Level 1 cyber resilience.
- Enhanced Eurotherm PID — cutback, wireable function blocks, and FM approvals by configuration.
Typical applications
- Heat-treat and aerospace thermal processes needing AMS2750F/CQI-9-capable accuracy.
- OEM panels that want native Ethernet PID with ramp/soak recipes.
- Retrofits replacing single-loop Eurotherm controllers with EPC3000 series.
Selection guide
- Inputs / programs — Precision process/temperature inputs; up to 20 ramp/soak program profiles.
- Accuracy — Precision 0.1% inputs (meets AMS2750F and CQI-9 accuracy requirements per OEM docs).
- Control / output — Enhanced Eurotherm PID with cutback; wireable function blocks (math/logic/advanced control); FM-approved temperature limit option.
- Supply — per OEM order code.
- Communication — Native high-speed Ethernet (RJ45); Modbus, EtherNet/IP, BACnet; Achilles Level 1 certified cyber resilience.
- Mounting — Panel-mounted programmable single-loop PID controller.
- Approvals — Achilles Level 1; Factory Mutual (FM) limit option; AMS2750F / CQI-9 relevant accuracy claims.
- Notes — Designed for digitized Industry 4.0 / IIoT thermal and process applications.
Common mistakes
- Ordering without confirming whether the FM-approved temperature limit option is required — it is optional per OEM documentation.
- Assuming AMS2750F / CQI-9 “compliance” beyond the published 0.1% input accuracy claim — match your audit checklist to the OEM wording and certificates.
- Leaving Ethernet protocol undefined (Modbus vs EtherNet/IP vs BACnet) when the host expects a specific stack.
- Expecting ambient, IP, or exact supply voltage from this page — those fields are not filled in the OEM extract used here; send panel environment and available supply in the RFQ.
- Specifying multi-loop control on this series description — product data describes a programmable single-loop PID controller.
- Automation & control · Automation & control buying guide
When to RFQ / what to tell us
- Sensor/process input type and required measuring range / units.
- Whether ramp/soak profiling is needed (up to 20 profiles) and typical program structure.
- Control outputs and whether FM-approved temperature limit option is required.
- Ethernet protocol (Modbus / EtherNet/IP / BACnet) and cybersecurity / Achilles expectation.
- Panel cutout / mounting constraints, available supply, quantity, ship-to country.
- Any AMS2750F / CQI-9 documentation you must match.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 50181 |
| Brand | Eurotherm |
| Model | EPC3000 Series |
| Product type | other (temperature / process controller) |
| Measuring range | Precision process/temperature inputs; up to 20 ramp/soak program profiles |
| Accuracy | Precision 0.1% inputs (meets AMS2750F and CQI-9 accuracy requirements per OEM docs) |
| Output signal | Enhanced Eurotherm PID with cutback; wireable function blocks (math/logic/advanced control); FM-approved temperature limit option |
| Supply voltage | per OEM order code |
| Communication | Native high-speed Ethernet (RJ45); Modbus, EtherNet/IP, BACnet; Achilles Level 1 certified cyber resilience |
| Approvals | Achilles Level 1; Factory Mutual (FM) limit option; AMS2750F / CQI-9 relevant accuracy claims |
| Mounting | Panel-mounted programmable single-loop PID controller |
| Notes | Designed for digitized Industry 4.0 / IIoT thermal and process applications. |
Documents
FAQ
Q: Single-loop or multi-loop? A: Product data describes a panel-mounted programmable single-loop PID controller with up to 20 ramp/soak profiles. If you need multi-loop, say so in the RFQ and we will steer selection.
Q: Does 0.1% input accuracy mean AMS2750F / CQI-9 certified? A: OEM documentation states precision 0.1% inputs that meet AMS2750F and CQI-9 accuracy requirements. Bring your audit checklist — we only claim what the OEM documentation and certificates support.
Q: Which communications are available? A: Native Ethernet (RJ45) with Modbus, EtherNet/IP, and BACnet listed; Achilles Level 1 certified cyber resilience. Lock protocol on the order code.
Q: What should I send for a quote? A: Input type, profiling need, outputs / FM limit option, Ethernet protocol, supply, quantity. Compatible with systems using Eurotherm EPC3000 if you need a drop-in check — we do not claim authorized-dealer status.
Links
| Parameter | Value |
|---|---|
| Measuring range | Precision process/temperature inputs; up to 20 ramp/soak program profiles |
| Accuracy | Precision 0.1% inputs (meets AMS2750F and CQI-9 accuracy requirements per datasheet) |
| Output | Enhanced Eurotherm PID with cutback; wireable function blocks (math/logic/advanced control); FM-approved temperature limit option |
| Supply | Per datasheet / order code |
| Communication | Native high-speed Ethernet (RJ45); Modbus, EtherNet/IP, BACnet; Achilles Level 1 certified cyber resilience |
| Approvals | Achilles Level 1; Factory Mutual (FM) limit option; AMS2750F / CQI-9 relevant accuracy claims |
| Mounting | Panel-mounted programmable single-loop PID controller |
| Notes | Designed for digitized Industry 4.0 / IIoT thermal and process applications. |