Bacharach

Bacharach H-10 PRO Refrigerant Leak Detector

SKU · 41112 · H-10 PRO Refrigerant Leak Detector · Brand: Bacharach
Available
Quote on request
No online payment · add lines to RFQ BOM

H-10 PRO: heated diode; 0.006 oz/yr; R-410A/134a/HFO; 1 s response. RFQ.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Type
Portable heated-diode universal refrigerant leak detector (H-10 PRO)
Refrigerants
Non-flammable CFC/HFC/HCFC/HFO including R-410A, R-134a, R-404A, HFO-1234yf/ze
Sensitivity
0.006 oz/yr stationary; 0.1 oz/yr moving (SAE J2791)
Response Time
1 second
Indicators
Visual red LED in probe tip + audible (speaker or headphones)
Probe
4.5 ft (1.37 m) flexible probe
Download datasheet PDF

Fits HVAC/R leak hunting where you need a Bacharach H-10 PRO—portable heated-diode universal detector for non-flammable CFC/HFC/HCFC/HFO refrigerants including R-410A, R-134a, R-404A and HFO-1234yf/ze, with sensitivity 0.006 oz/yr stationary and 0.1 oz/yr moving (SAE J2791) and about 1 second response.

Key advantages

  • Sensor — Heated-diode universal refrigerant detector
  • Refrigerants — CFC/HFC/HCFC/HFO incl. R-410A, R-134a, HFO-1234yf/ze
  • Sensitivity — 0.006 oz/yr stationary; 0.1 oz/yr moving (SAE J2791)
  • Response — About 1 second
  • Indicators — Probe-tip red LED + audible

Typical applications

  • HVAC refrigerant leak surveys.
  • Cold-room leak location.
  • Service truck leak detection.

Selection guide

  • Spare tips / filters
  • Headphones
  • Battery pack

Common mistakes

  • Using on flammables outside rating.
  • Dirty tip filters.
  • Air drafts masking leaks.

When to RFQ / what to tell us

  1. Accessories.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU41112
BrandBacharach
ModelH-10 PRO Refrigerant Leak Detector
Product typeRefrigerant Leak Detector
TypePortable heated-diode universal refrigerant leak detector (H-10 PRO)
RefrigerantsNon-flammable CFC/HFC/HCFC/HFO including R-410A, R-134a, R-404A, HFO-1234yf/ze
Sensitivity0.006 oz/yr stationary; 0.1 oz/yr moving (SAE J2791)
Response time1 second
IndicatorsVisual red LED in probe tip + audible (speaker or headphones)

Documents

FAQ

Q: Sensitivity? A: 0.006 oz/yr stationary; 0.1 oz/yr moving (SAE J2791).

Q: Response? A: About 1 second.

Q: What should I send for a quote? A: Accessories/quantity, ship-to.

Links

ParameterValue
TypePortable heated-diode universal refrigerant leak detector (H-10 PRO)
RefrigerantsNon-flammable CFC/HFC/HCFC/HFO including R-410A, R-134a, R-404A, HFO-1234yf/ze
Sensitivity0.006 oz/yr stationary; 0.1 oz/yr moving (SAE J2791)
Response Time1 second
IndicatorsVisual red LED in probe tip + audible (speaker or headphones)
Probe4.5 ft (1.37 m) flexible probe
PowerBattery or 100–240 VAC wall adapter (N. American / international plug kits)
Part Numbers3015-8004 (N. American plug); 3015-8005 (international plugs)
Not ForNot for combustible/flammable A2/A3 refrigerants or hazardous locations
Brand LineMSA Bacharach H-10 PRO