Image unavailable
Image unavailable
Hedland
Hedland Air / Compressed Gas Flow Meter
Quote on request
No online payment · add lines to RFQ BOM
Inline air/gas VA meter. 0.5–2200 scfm class; to 1500 psi. RFQ + engineer selection help.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Accuracy
±2% of full scale (±7% on ¼ in models)
Mounting
Inline installation; compressibility correction guidance in UM
Type
Inline pneumatic / air & compressed-gas variable-area flow meter
Size Range
6–80 mm (¼–3 in) connection sizes
Flow Range
0.2–1130 L/s (0.5–2200 scfm) typical family coverage
Temperature Range
−29…+116 °C (−20…+240 °F)
Fits compressed-air and gas lines where you need an inline Hedland variable-area meter with direct visual reading up to 1500 psi class.
Key advantages
- Air / gas VA meter — Inline pneumatic / air & compressed-gas variable-area flow meter
- Flow coverage — 0.2–1130 L/s (0.5–2200 scfm) typical family coverage across 6–80 mm (¼–3 in) connection sizes
- Pressure / temperature — Up to 103 bar (1500 psi); −29…+116 °C (−20…+240 °F)
- Accuracy — ±2% of full scale (±7% on ¼ in models)
- Indication — Direct visual reading; multi-pressure and single-pressure scales
Typical applications
- Pneumatic system monitoring and tool-air flow indication.
- Compressor efficiency checks on compressed-gas lines.
- Inline air/gas VA metering where electronics-free visual reading is preferred.
Selection guide
- Media — Air and compressed gases (pneumatic systems, compressor efficiency, tools)
- Connection size — 6–80 mm (¼–3 in) connection sizes
- Flow range — 0.2–1130 L/s (0.5–2200 scfm) typical family coverage
- Pressure / temperature — Up to 103 bar (1500 psi); −29…+116 °C (−20…+240 °F)
- Accuracy — ±2% of full scale (±7% on ¼ in models) — note ±7% on ¼ in models.
- Scale type — multi-pressure vs single-pressure scales.
Common mistakes
- Ignoring compressibility correction on gas service — follow the pneumatic UM guidance.
- Sizing on peak scfm without checking the ¼ in accuracy exception (±7% FS).
- Assuming liquid Hedland catalogs apply — this SKU is the air/compressed-gas family.
When to RFQ / what to tell us
- Gas type, pressure, temperature, and target flow (scfm or L/s).
- Connection size (¼–3 in) and end fitting preference.
- Multi-pressure vs single-pressure scale; quantity; ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 10110 |
| Brand | Hedland |
| Model | Air / Compressed Gas Flow Meter |
| Product type | Variable-Area Flow Meter |
| Type | Inline pneumatic / air & compressed-gas variable-area flow meter |
| Size range | 6–80 mm (¼–3 in) connection sizes |
| Flow range | 0.2–1130 L/s (0.5–2200 scfm) typical family coverage |
| Temperature | −29…+116 °C (−20…+240 °F) |
| Pressure | Up to 103 bar (1500 psi) |
| Accuracy | ±2% of full scale (±7% on ¼ in models) |
| Indication | Direct visual reading; multi-pressure and single-pressure scales |
| Media | Air and compressed gases (pneumatic systems, compressor efficiency, tools) |
| Mounting | Inline installation; compressibility correction guidance in UM |
| Application | Pneumatic system monitoring and compressed-air flow indication |
Documents
- OEM datasheet on file:
hedland/10110-va-catalog.pdf(ask on RFQ for PDF link)
FAQ
Q: What accuracy is published? A: ±2% of full scale (±7% on ¼ in models) per Hedland pneumatic VA data.
Q: Max pressure? A: Up to 103 bar (1500 psi) family rating — confirm the exact size code.
Q: What should I send for a quote? A: Gas, P/T, flow, size, scale type, quantity.
Links
| Parameter | Value |
|---|---|
| Accuracy | ±2% of full scale (±7% on ¼ in models) |
| Mounting | Inline installation; compressibility correction guidance in UM |
| Type | Inline pneumatic / air & compressed-gas variable-area flow meter |
| Size Range | 6–80 mm (¼–3 in) connection sizes |
| Flow Range | 0.2–1130 L/s (0.5–2200 scfm) typical family coverage |
| Temperature Range | −29…+116 °C (−20…+240 °F) |
| Pressure Range | Up to 103 bar (1500 psi) |
| Indication | Direct visual reading; multi-pressure and single-pressure scales |
| Media | Air and compressed gases (pneumatic systems, compressor efficiency, tools) |
| Document | Hedland VA product catalog + Inline Pneumatic Flow Meter UM VAM-UM-00593-EN |
| Application | Pneumatic system monitoring and compressed-air flow indication |